Square D XMLP200PD230 Data Sheet

Product data sheet
Characteristics
XMLP200PD230
pressure transmitter - XMLP - 200psi - 1/4"18NPT
- 4..20mA - M12 - set 1
Product availability : Stock - Normally stocked in distribution facility
Main
Range of product OsiSense XM
Pressure sensor type Pressure transmitter
Pressure sensor name XMLP
Electrical circuit type Control circuit
Pressure sensor size 1378.95kPa (200psi)
Local display Without
Controlled fluid Fresh water 32…275°F (0…135°C))
Fluid connection type 1/4" - 18 NPT (male)
Electrical connection 1 male connector M12 4 pins
[Us] rated supply voltage 12...24 V DC SELV 7…33V)
Current consumption < 23 mA
Type of output signal Analogue
Analogue output function 4...20 mA, 2-wire
Quantity per set Set of 1
Type of packing Individual
Air -40…275°F (-40…135°C)) Hydraulic oil -40…275°F (-40…135°C)) Gas -40…275°F (-40…135°C)) Refrigeration fluid -40…275°F (-40…135°C))
Complementary
Pressure setting range 0.00…1378.95kPa (0…200psi)
Maximum permissible accidental pressure
Destruction pressure 9652.66kPa (1400psi)
Materials in contact with fluid Stainless steel AISI 316L
Feb 20, 2020
4136.85kPa (600psi)
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
1
Operating position Any position
Protection type Reverse polarity
Electromagnetic compatibility Electrostatic discharge immunity test EN/IEC 61000-4-2 8 kV air, 4 kV contact
[Uimp] rated impulse withstand voltage 0.5kV
Response time on output <= 2 ms 10...90 % of full scale
Measurement accuracy +/- 0.5 % of the measuring range
Resolution 0.1 % of the measuring range
Drift of the sensitivity +/- 0.02 % of measuring range/°K
Drift of the zero point +/- 0.02 % of measuring range/°K
Mechanical durability 10000000cycles
Net weight 0.19lb(US) (0.088kg)
Diameter 1.02in (26mm)
Length 1.42in (36mm)
Load short-circuit
1.2/50 µs shock waves immunity test EN/IEC 61000-4-5 1 kV 42 Ohm Immunity to magnetic fields EN/IEC 61000-4-8 100 A/m 50 Hz Electrical fast transient/burst immunity test EN/IEC 61000-4-4 4 kV Susceptibility to electromagnetic fields EN/IEC 61000-4-3 10 V/m 80...3000 MHz Radiated RF fields EN/IEC 61000-4-6 10 V 0.01...80 MHz
Environment
Standards NSF ANSI 61
Product certifications CE
Protective treatment TC
Ambient air temperature for operation -22…185°F (-30…85°C)
Ambient air temperature for storage -58…212°F (-50…100°C)
Vibration resistance 20 gn (f = 15…2000Hz) conforming to EN/IEC 60068-2-6
Shock resistance 100 gn 11ms EN/IEC 60068-2-27
IP degree of protection IP65 EN/IEC 60529
EN/IEC 61326-2-3
EAC CULus RCM
IP67 EN/IEC 60529 IP69K EN/IEC 60529
Ordering and shipping details
Category 22419 - PRESSURE SWITCH IEC (HIGH,LOW,GEN)
Discount Schedule DS2
GTIN 00785901717430
Returnability Yes
Country of origin CH
Offer Sustainability
Sustainable offer status Green Premium product
California proposition 65 WARNING: This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and
REACh free of SVHC Yes
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free Yes
RoHS exemption information Yes
Environmental Disclosure Product Environmental Profile
Circularity Profile No need of specific recycling operations