The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Product data sheet
Characteristics
XCKP2118N12
limit switch XCKP - thermoplastic roller lever 1NC+1NO - snap - 1/2NPT
Main
Range of product OsiSense XC
Series name Standard format
Product or component
type
Device short name XCKP
Sensor design Compact form A conforming to CENELEC EN 50047
Body type Fixed
Head type Rotary head
Material Plastic
Body material Plastic
Head material Zamak
Movement of operating
head
Type of operator Spring return roller lever thermoplastic
Type of approach Lateral approach 2 directions
Number of poles 2
Contacts type and composition
Contacts operation Snap action
Limit switch
Rotary
1 NC + 1 NO
Complementary
Tracks 24/40 mm
Switch actuation By 30° cam
Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Cable entry 1 entry tapped for 1/2" NPT cable gland
Contacts insulation form Zb
Positive opening With
Positive opening minimum torque 0.25 N.m
Minimum torque for tripping 0.1 N.m
Maximum actuation speed 1.5 m/s
Repeat accuracy 0.1 mm on the tripping points with 1 million operating cycles
Contact code designation A300, AC-15 (Ue = 240 V, Ie = 3 A) , Ithe = 10 A conforming to EN/IEC
[Ui] rated insulation voltage 300 V conforming to UL 508
Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664
Short circuit protection 10 A cartridge fuse gG
Electrical durability 5000000 cycles, DC-13, 120 V, 4 W, operating rate: <= 60 cyc/mn, load factor:
Mechanical durability 10000000 cycles
60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A
500 V degree of pollution 3 conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
6 kV conforming to IEC 60947-1
0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor:
0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5
conforming to IEC 60947-5-1 appendix C
Dec 15, 2016
1

Environment
Shock resistance 50 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance 25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
IP degree of protection IP66 conforming to IEC 60529
IK degree of protection IK04 conforming to EN 50102
Class of protection against electric shock Class II conforming to IEC 61140
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -40...70 °C
Protective treatment TC
Product certifications CCC
Standards EN 60204-1
IP67 conforming to IEC 60529
Class II conforming to NF C 20-030
CSA
UL
EN 60947-5-1
IEC 60204-1
IEC 60947-5-1
UL 508
CSA C22.2 No 14
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW)
REACh Reference not containing SVHC above the threshold
Compliant - since 1037 - Schneider Electric declaration of conformity
2