Product data sheet
Characteristics
XB4BS84441
Red Ø40 Emergency stop, switching off Ø22
latching turn release 2NC+1NO
Main
Range of product Harmony XB4
Product or component type Complete emergency stop push-button
Device short name XB4
Bezel material Chromium plated metal
Fixing collar material Zamak
Mounting diameter 22 mm
Sale per indivisible quantity 1
Shape of signaling unit head Round
Type of operator Trigger action and mechanical latching
Reset Turn to release
Operator profile Red mushroom Ø 40 mm unmarked
Contacts type and composition 2 NC + 1 NO
Contact operation Slow-break
Connections - terminals Screw clamp terminals : <= 2 x 1.5 mm² with cable end conforming to EN 60947-1
Complete emergency switching off push-button
Screw clamp terminals : >= 1 x 0.22 mm² without cable end conforming to EN 60947-1
Complementary
Height 47 mm
Width 40 mm
Depth 82 mm
Terminals description ISO n°1 (13-14)NO
Resistance to high pressure washer 7000000 Pa at 55 °C,distance: 0.1 m
Contacts usage Standard contacts
Positive opening With positive opening conforming to EN/IEC 60947-5-1 appendix K
Operating travel 1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Oct 06, 2017
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
1

Mechanical durability 300000 cycles
Tightening torque 0.8...1.2 N.m conforming to EN 60947-1
Shape of screw head Cross head compatible with Philips no 1 screwdriver
Contacts material Silver alloy (Ag/Ni)
Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal
current
[Ui] rated insulation voltage 600 V (degree of pollution: 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-1
[Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/
Electrical reliability Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4
Cross head compatible with pozidriv No 1 screwdriver
Slotted head compatible with flat Ø 4 mm screwdriver
Slotted head compatible with flat Ø 5.5 mm screwdriver
10 A conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to
EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/
IEC 60947-5-1 appendix C
Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4
Environment
Protective treatment TH
Ambient air temperature for storage -40...70 °C
Ambient air temperature for operation -40...70 °C
Electrical shock protection class Class I conforming to IEC 60536
IP degree of protection IP69
NEMA degree of protection NEMA 13
IK degree of protection IK06 conforming to IEC 50102
Standards EN/IEC 60947-5-4
Product certifications UL listed
Vibration resistance 5 gn (f = 2...500 Hz) conforming to IEC 60068-2-6
Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
IP66 conforming to IEC 60529
IP69K
NEMA 4X
UL 508
JIS C 4520
EN/ISO 13850
IEC 60364-5-53
EN/IEC 60947-5-1
EN/IEC 60947-5-5
EN/IEC 60947-1
CSA C22.2 No 14
EN/IEC 60204-1
LROS (Lloyds register of shipping)
CSA
RINA
GL
BV
DNV
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
2