Square D Transformers Catalog

Table of Contents
Section 6
Transformers
Miscellaneous 6-1
Class 7400 6-2
General Purpose Dry Type 600 Volts and Below 6-3
K-Rated Transformers 6-3 Drive Isolation Transformers 6-5 Open Core and Coil Transformers 6-6
Industrial Control 6-7
Type EO Transformers 6-7 Type T and MultiTap
TM
Transformers 6-7
Instrument 600 Volt Class 6-8
Voltage and Current Transformers 6-9 Toroidal Current Transformers 6-10
Toroidal Current Transformers (64R, 74R, 66R, 76R) 6-10 Toroidal Current Transformers (110R, 110R, 120R, 140R) 6-10 Toroidal Current Transformers (152R, 170R, 180R, 210R) 6-11 Toroidal Current Transformers (200R, 201R, 202R, 203R) 6-12 Shorting Terminal Blocks 6-12
Current Transformers: Multi-Ratio, Rectangular, Split-Core 6-12
Multi-Ratio Current Transformers 6-12 Rectangular Window Current Transformers 6-13 Split-Core Current Transformers 6-13
Current Transformers: Bushing, Auxiliary 6-14
Bushing Current Transformers 50–400 Hz 6-14 Auxiliary Current Transformers 6-14
Transformers—Obsolete 6-15
Obsolete—January 1, 2016Energy Efficient Three-Phase 6-15 Obsolete—January 1, 2016EE Watchdog Transformers 6-16 Obsolete—January 1, 2016EE NL and NLP Series Transformers 6-17
© 2019 Schneider Electric All Rights Reserved
TRANSFORMERS
6
6-1
Miscellaneous
Enclosure Dimensions and Accessories
Class 7400
schneider-electric.us
Enclosure
Number/
Style
1 A 5.00 127 4.47 114 3.44 87 Wall 2 A 5.50 140 4.47 114 3.44 87 Wall 105 3 A 5.00 127 4.85 123 3.75 95 Wall 105 4 A 5.50 140 5.23 133 4.06 103 Wall 130 5 A 6.19 157 6.19 157 4.69 119 Wall 130 6 A 6.69 170 6.19 157 4.69 119 Wall 180 7 A 8.13 270 6.94 176 5.31 135 Wall 180 8 A 8.25 210 8.68 220 6.56 167 Wall 180
9 A 9.56 243 8.68 220 6.56 167 Wall 180 10 A 10.50 267 8.62 219 6.50 165 Wall 180 11 A 12.56 319 8.62 219 6.50 165 Wall 180 12 C 13.50 343 14.75 375 9.00 229 Wall 180 13 B 14.75 375 9.75 248 11.75 298 Wall 180 14 C 14.75 375 19.10 485 12.25 311 Wall 180 15 B 20.00 508 15.00 381 13.50 343 Wall 180 16 C 22.00 559 25.00 635 13.50 343 Wall 180
D 27.00 686 20.00 508 16.00 406 Floor WS363 WMB361362 CMB363 220
17
E 27.00 686 20.00 508 16.00 406 Floor H 37.00 940 20.00 508 16.00 406 Floor WS363 WMB361362 CMB363 220 D 30.00 762 20.00 508 20.00 508 Floor WS363 WMB363364 CMB363 220
18
E 30.00 762 20.00 508 20.00 508 Floor H 37.00 940 20.00 508 20.00 508 Floor WS363 WMB363364 CMB363 220 D 30.00 762 30.00 762 20.00 508 Floor WS364 WMB363364 CMB364 220
19
E 30.00 762 30.00 762 20.00 508 Floor D 37.00 940 30.00 762 20.00 508 Floor WS364 WMB363364 CMB364 220
20
E 37.00 940 30.00 762 20.00 508 Floor D 37.00 940 30.00 762 24.00 610 Floor WS364 CMB364 220
21
E 37.00 940 30.00 762 24.00 610 Floor D 43.75 1111 32.00 813 27.00 686 Floor WS380 CMB380 220
22
E 43.75 1111 32.00 813 27.00 686 Floor
23 E 48 1219 48 1219 29.5 749 Floor
D 49.5 1257 35 889 28.5 724 Floor WS381 CMB381 220
24
E 49.5 1257 35 889 28.5 724 Floor Note 5 CMB381 220 D 49.5 1257 41 1041 32 813 Floor WS382 220
25
E 49.5 1257 41 1041 32 813 Floor
26 D 57.5 1461 41 1041 32 813 Floor WS382 220
D 60 1524 56 1422 36 914 Floor WS370A 220
28
E 60 1524 56 1422 36 914 Floor
29 D 68 1727 56 1422 36 914 Floor WS370A 220
D 71 1803 48 1219 36 914 Floor WS383 220
30
E 71 1803 48 1219 36 914 Floor D 74 1880 56 1422 40.5 1029 Floor WS384 220
31
E 74 1880 56 1422 40.5 1029 Floor 32 F 91.5 2388 56 1422 54 1372 Floor 33 F 94 2388 72 1829 54 1372 Floor 220 34 F 94 2388 84 2134 54 1372 Floor 220 35 F 94 2388 96 2438 54 1372 Floor 220 36 D 40.5 1031 36.5 916 21.75 553 Floor 220 37 D 51.5 1310 40.5 1031 26.5 674 Floor 220 38 D 66 1679 50.5 1285 32 814 Floor 220 39 F 90 2290 80 2036 50 1272 Floor 220 40 F 90 2290 90 2290 50 1272 Floor 220 41 F 100 2545 100 2545 60 1527 Floor 220
6
42 F 108 2748 108 2748 60 1527 Floor 220 43 F 90 2290 64 1628 44 1120 Floor 220 44 F 90 2290 72 1832 50 1272 Floor 220 45 D 80 2036 64 1628 44 1120 Floor 220 51 X 9.5 24 10 25 7.75 20 Wall 52 X 12 30 13.75 35 13.75 35 Wall 180 53 X 24 61 21.5 55 16.38 42 Wall 180 54 X 23 58 25.5 65 13.75 35 Wall 180
TRANSFORMERS
55 X 31.5 80 31.5 80 16.25 41 Wall 180 61 HX 62 HX 63 HX
Height
In. mm In. mm In. mm
Width
Depth
Contact your local Schneider Electric representative for details.
NOTE: Wall mounting brackets are used with units weighing no more than 700 lbs. Ceiling mounting brackets are used with units weighing no more than 1200 lbs. Weathershields are available for units 600 Volts and below. For 2.4, 5, and 15 kV units suitable for outdoor use, contact the factory.
Mounting
Weather-
shield
[2] [3]
[4]
[4]
[4]
[4]
[4]
[4] [5]
[4]
[4]
[4]
[4]
[6]
[7] [3]
Wall Mounting
Bracket
WMB361362 CMB363 220
WMB363364 CMB363 220
WMB363364 CMB364 220
WMB363364 CMB364 220
CMB364 220
CMB380 220 — 220
220
220
220
220 — 220
Ceiling
Mounting
Bracket
Enclosure Dimensions and Accessories [1]
Insulation
Class
105
180
o
C
[1] These dimensions are not for construction. Contact your local Schneider Electric representative for certified prints. [2] Transformer is NEMA Type 3R Standard. Weathershield not required for outdoor use. [3] Wall mounting brackets are a standard part of transformer enclosure. Accessory not required. [4] Indoor/outdoor enclosure standard. Weathershield not required. [5] Indoor/outdoor enclosure standard. Weathershield not required. [6] Special outdoor construction required for NEMA Type 3R applications. Contact your local Schneider Electric representative for details. [7] Transformer is NEMA Type 4X Standard. Weathershield not required.
6-2
© 2019 Schneider Electric
All Rights Reserved
K-Rated Transformers General Purpose Dry Type 600 Volts and
schneider-electric.us
As a partner in the NEMA Premium Transformer Program, Schneider Electric has determined that this product meets the NEMA Premium Efficiency specifications for premium energy efficiency.
Class 7400
Below
Obsolete—October 1, 2015 K-Rated, Three-Phase (15–1000 kVA)
K-rated transformers mitigate Triplen harmonics via a Delta-Wye configuration.
Aluminum or copper windings
Isolation transformer with electrostatic shield
K-4 and K-13 levels
Harmonic Mitigating, Three-Phase (15–1000 kVA)
Harmonic Mitigating transformers mitigate Triplen harmonics via electromagnetic phase relations. They remove 5th and 7th harmonics when using dual devices with a 0° and a +30° phase shift. They further reduce 11th and 13th harmonics when a +15° or -15° shift is added to the dual devices. Available with:
Aluminum or copper windings
Isolation transformer
NEMA Premium
Table 6.1: 480 V Delta Primary, 208Y/120 Secondary
kVA
NP Series for Typical Non-Linear Load Service— K-9 Rated—Copper Windings; 130 °C Rise
15 EP15T3HNISCUNP 6–2.5% 2+4– 310 17D 30 EP30T3HNISCUNP 6–2.5% 2+4– 340 18D 45 EP45T3HNISCUNP 6–2.5% 2+4– 418 20D 75 EP75T3HNISCUNP 6–2.5% 2+4– 642 21D
112.5 EP112T3HNISCUNP 6–2.5% 2+4– 725 22D 150 EP150T3HNISCUNP 6–2.5% 2+4– 915 24D 225 EP225T3HNISCUNP 6–2.5% 2+4– 1125 25D 300 EP300T3HNISCUNP 4–2.5% 2+2– 1535 30D
NP Series for Typical Non-Linear Load Service— K-9Rated—Copper Windings; 115 °C Rise
15 EP15T3HFISCUNP 6–2.5% 2+4– 310 17D 30 EP30T3HFISCUNP 6–2.5% 2+4– 340 18D 45 EP45T3HFISCUNP 6–2.5% 2+4– 418 20D 75 EP75T3HFISCUNP 6–2.5% 2+4– 642 20D
112.5 EP112T3HFISCUNP 6–2.5% 2+4– 725 22D 150 EP150T3HFISCUNP 6–2.5% 2+4– 915 24D 225 EP225T3HFISCUNP 6–2.5% 2+4– 1125 25D 300 EP300T3HFISCUNP 4–2.5% 2+2– 1535 25D
NLP Series for More Severe Non-Linear Load Service—K-13 Rated—Copper Windings; 150 °C Rise
15 EP15T3HISCUNLP 6–2.5% 2+4– 260 17D 30 EP30T3HISCUNLP 6–2.5% 2+4– 430 18D 45 EP45T3HISCUNLP 6–2.5% 2+4– 730 20D 75 EP75T3HISCUNLP 6–2.5% 2+4– 640 20D
112.5 EP112T3HISCUNLP 6–2.5% 2+4– 985 22D 150 EP150T3HISCUNLP 6–2.5% 2+4– 1135 24D 225 EP225T3HISCUNLP 6–2.5% 2+4– 300 EP300T68HISCUNLP 4–2.5% 2+2– 2650 30D
Catalog No. Taps Weight (lbs)
1477 25D
Enclosure
© 2019 Schneider Electric All Rights Reserved
TRANSFORMERS
6
6-3
General Purpose Dry Type 600 Volts and Below
K-Rated Transformers
Class 7400
Obsolete—October 1, 2015
Table 6.2: Harmonic Mitigating, 480 Primary to 208zz/120 Secondary; Copper Windings
kVA
0° Phase Shift
15 HM15T208HNCUEP 6–2.5% 2+4– 310 17D 30 HM30T208HNCUEP 6–2.5% 2+4– 340 17D 45 HM45T208HNCUEP 6–2.5% 2+4– 418 18D 75 HM75T208HNCUEP 6–2.5% 2+4– 642 20D
112.5 HM112T208HNCUEP 6–2.5% 2+4– 725 21D 150 HM150T208HNCUEP 6–2.5% 2+4– 915 22D 225 HM225T208HNCUEP 6–2.5% 2+4– 1125 24D 300 HM300T208HNCUEP 6–2.5% 2+4– 1535 25D
30° Phase Shift
15 HM15T255HNCUEP 3-5%1+2- 310 17D 30 HM30T255HNCUEP 3-5%1+2- 340 17D 45 HM45T255HNCUEP 3-5%1+2- 418 18D 75 HM75T255HNCUEP 3-5%1+2- 642 20D
112.5 HM112T255HNCUEP 3-5%1+2- 725 21D 150 HM150T255HNCUEP 3-5%1+2- 915 22D 225 HM225T255HNCUEP 3-5%1+2- 1125 24D 300 HM300T255HNCUEP 3-5%1+2- 1535 25D
+15° Phase Shift
15 HM15T251HNCUEP 6–2.5% 2+4– 310 17D 30 HM30T251HNCUEP 6–2.5% 2+4– 340 17D 45 HM45T251HNCUEP 6–2.5% 2+4– 418 18D 75 HM75T251HNCUEP 6–2.5% 2+4– 642 20D
112.5 HM112T251HNCUEP 6–2.5% 2+4– 725 21D 150 HM150T251HNCUEP 6–2.5% 2+4– 915 22D 225 HM225T251HNCUEP 6–2.5% 2+4– 1125 24D 300 HM300T251HNCUEP 6–2.5% 2+4– 1535 25D
-15° Phase Shift
15 HM15T259HNCUEP 6–2.5% 2+4– 310 17D 30 HM30T259HNCUEP 6–2.5% 2+4– 340 17D 45 HM45T259HNCUEP 6–2.5% 2+4– 418 18D 75 HM75T259HNCUEP 6–2.5% 2+4– 642 20D
112.5 HM112T259HNCUEP 6–2.5% 2+4– 725 21D 150 HM150T259HNCUEP 6–2.5% 2+4– 915 22D 225 HM225T259HNCUEP 6–2.5% 2+4– 1125 24D 300 HM300T259HNCUEP 6–2.5% 2+4– 1535 25D
Additional temperature rises are available; for part numbers, see the Schneider Electric Product Configurator.
Catalog
No.
Taps Weight (lbs)
schneider-electric.us
Enclosure
6
TRANSFORMERS
6-4
© 2019 Schneider Electric
All Rights Reserved
Drive Isolation Transformers General Purpose Dry Type 600 Volts and
schneider-electric.us
Class 7400
Drive Isolation Transformers
Special design considerations must be made for the requirements of both adjustable frequency and dc motor drive power isolation. Allowance for high surge, harmonic and offset currents are taken into account in the design of Square D transformers. Drive isolation transformers are not shielded isolation transformers, but act to lessen transient generation into the supply power and act as a buffer for SCR current surges.
Table 6.3: Three-Phase 60 Hz; Class B (IEEE Standard 597-1983); 460 V Delta Primary
kVA
460 V Delta Primary, 460Y/265 V Secondary, 150 °C Rise
7.5 7T145HDIT 2–5%1 + 1– 180 17D 11 11T145HDIT 2–5%1 + 1– 180 17D 15 15T145HDIT 2–5%1 + 1– 190 17D 20 20T145HDIT 2–5%1 + 1– 210 17D 27 27T145HDIT 2–5%1 + 1– 250 17D 34 34T145HDIT 2–5%1 + 1– 295 18D 40 40T145HDIT 2–5%1 + 1– 350 18D 51 51T145HDIT 2–5%1 + 1– 445 20D 63 63T145HDIT 2–5%1 + 1– 465 20D 75 75T145HDIT 2–5%1 + 1– 550 20D 93 93T145HDIT 2–5%1 + 1– 845 22D
118 118T145HDIT 2–5%1 + 1– 920 22D 145 145T145HDIT 2–5%1 + 1– 1025 22D 175 175T145HDIT 2–5%1 + 1– 1120 25D 220 220T145HDIT 2–5%1 + 1– 1200 25D 275 275T145HDIT 2–5%1 + 1– 1500 25D 330 330T145HDIT 2–5%1 + 1– 1390 25D 440 440T145HDIT 2–5%1 + 1– 2700 30D 550 550T145HDIT 2–5%1 + 1– 3800 30D
460 V Delta Primary, 230Y/132 V Secondary, 150 °C Rise
7.5 7T144HDIT 2–5%1 + 1– 180 17D 11 11T144HDIT 15 15T144HDIT 2–5%1 + 1– 190 17D 20 20T144HDIT 2–5%1 + 1– 210 17D 27 27T144HDIT 34 34T144HDIT 2–5%1 + 1– 295 18D 40 40T144HDIT 2–5%1 + 1– 350 18D 51 51T144HDIT 2–5%1 + 1– 445 20D 63 63T144HDIT 2–5%1 + 1– 465 20D 75 75T144HDIT 2–5%1 + 1– 550 20D 93 93T144HDIT 2–5%1 + 1– 845 22D
118 118T144HDIT 2–5%1 + 1– 920 22D 145 145T144HDIT 2–5%1 + 1– 1025 22D 175 175T144HDIT 2–5%1 + 1– 1120 25D 220 220T144HDIT 2–5%1 + 1– 1200 25D 275 275T144HDIT 2–5%1 + 1– 1500 25D 330 330T144HDIT 2–5%1 + 1– 1390 25D 440 440T144HDIT 2–5%1 + 1– 2700 30D 550 550T144HDIT 2–5%1 + 1– 3800 30D
Catalog
No.
Full Capacity Taps Weight (lbs) [1]
2–5%1 + 1– 180 17D
2–5%1 + 1– 250 17D
Enclosure
[1][2]
brand drive isolation
Table 6.4: Three-Phase 60 Hz; Class B (IEEE Standard 597-1983); 230 V Delta Primary
kVA
230 V Delta Primary, 460Y/265 V Secondary, 150 °C Rise
7.5 7T143HDIT 2–5%1 + 1– 180 17D 11 11T143HDIT 2–5%1 + 1– 180 17D 15 15T143HDIT 2–5%1 + 1– 190 17D 20 20T143HDIT 2–5%1 + 1– 210 17D 27 27T143HDIT 2–5%1 + 1– 250 17D 34 34T143HDIT 2–5%1 + 1– 295 18D 40 40T143HDIT 2–5%1 + 1– 350 18D 51 51T143HDIT 2–5%1 + 1– 445 20D 63 63T143HDIT 2–5%1 + 1– 465 20D 75 75T143HDIT 2–5%1 + 1– 550 20D 93 93T143HDIT 2–5%1 + 1– 845 22D
118 118T143HDIT 2–5%1 + 1– 920 22D 145 145T143HDIT 2–5%1 + 1– 1025 22D 175 175T143HDIT 2–5%1 + 1– 1120 25D 220 220T143HDIT 2–5%1 + 1– 1200 25D 275 275T143HDIT 2–5%1 + 1– 1500 25D 330 330T143HDIT 2–5%1 + 1– 1390 25D 440 440T143HDIT 2–5%1 + 1– 2700 30D 550 550T143HDIT 2–5%1 + 1– 3800 30D
230 V Delta Primary, 230Y/132 V Secondary, 150 °C Rise
7.5 7T142HDIT 11 11T142HDIT 2–5%1 + 1– 180 17D 15 15T142HDIT 2–5%1 + 1– 190 17D 20 20T142HDIT 2–5%1 + 1– 210 17D 27 27T142HDIT 2–5%1 + 1– 250 17D 34 34T142HDIT 2–5%1 + 1– 295 18D 40 40T142HDIT 2–5%1 + 1– 350 18D 51 51T142HDIT 2–5%1 + 1– 445 20D 63 63T142HDIT 2–5%1 + 1– 465 20D 75 75T142HDIT 2–5%1 + 1– 550 20D 93 93T142HDIT 2–5%1 + 1– 845 22D
118 118T142HDIT 2–5%1 + 1– 920 22D 145 145T142HDIT 2–5%1 + 1– 1025 22D 175 175T142HDIT 2–5%1 + 1– 1120 25D 220 220T142HDIT 2–5%1 + 1– 1200 25D 275 275T142HDIT 2–5%1 + 1– 1500 25D 330 330T142HDIT 2–5%1 + 1– 1390 25D 440 440T142HDIT 2–5%1 + 1– 2700 30D 550 550T142HDIT 2–5%1 + 1– 3800 30D
Catalog
No.
Full Capacity
Taps
2–5%1 + 1– 180 17D
Weight (lbs)
[1]
NOTE: Lugs are furnished by customer.
Below
Enclosure
[1][2]
[1] Not for construction. Contact your nearest Schneider Electric sales office for certified prints. [2] For enclosure styles, see the dimensions table in Digest Section for Transformers.
© 2019 Schneider Electric All Rights Reserved
TRANSFORMERS
6
6-5
General Purpose Dry Type 600 Volts and
B
D
C
A
E
E
A
B
D
C
C
E
B
D
A
Below
Open Core and Coil Transformers
Class 7400 / Refer to Catalog 7400CT9601
schneider-electric.us
Open Core and Coil Transformers Designed for General Applications for 600 V and Below
Units are designed with 220 °C insulation, aluminum windings, top terminations, compact design to save space, and are UL component recognized for:
Non-energy efficiency (less than 15 kVA)
Single-phase 5–10 VA Three-phase 3–9 VA
Energy efficiency (meets Table 4-2 of NEMA TP1–2002)
Single-phase 15–75 kVA Three-phase 15–112.5 kVA
Figure 1
Figure 2
Figure 3
Table 6.5: Single-Phase Open Core and Coil Transformers—240 X 480 V Primary, 120/240 V Secondary, 60 Hz
kVA
5 5S1HFOC 115 8.00 203 9.00 229 11.00 279 8.00 203 8.00 203 66 1
7.5 7S1HFOC 115 8.00 203 9.00 229 14.25 362 8.00 203 8.50 216 80 1 10 10S1HFOC 115 20.50 521 18.5 470 14.00 356 17.0 432 4.25 108 140 2 15 EE15S3HOC 150
25 EE25S3HOC 150
37.5 EE37S3HOC 150 50 EE50S3HOC 150 75 EE75S3HOC 150
Catalog
No.
Deg.
C
Temp.
Rise
Full Capacity Taps
6–2.5% 2+4–[5] 6–2.5% 2+4–[5] 6–2.5% 2+4–[5] 6–2.5% 2+4–[5] 6–2.5% 2+4–[5]
A B C D
in mm in mm in mm in mm in mm
20.50 521 18.5 470 14.00 356 17.0 432 4.25 108 140 2
20.25 514 18.5 470 14.00 356 17.0 432 5.00 127 200 2
22.00 559 18.5 470 18.00 457 17.0 432 5.50 140 255 2
22.00 559 18.5 470 18.00 457 17.0 432 6.50 165 310 2
22.25 565 28.0 711 22.00 559 27.0 686 8.50 216 460 2
Dimensions [3]
E[4]
6
TRANSFORMERS
Weig-
ht
(lbs)
Figure
[3] Not for construction. Contact your nearest Schneider Electric sales office for certified prints. [4] Dimensions may vary due to manufacturing process. [5] When 240 V tap is used, there will be 3–5% taps, 1 above and 2 below.
6-6
© 2019 Schneider Electric
All Rights Reserved