Table of Contents
Section 6
Transformers
Miscellaneous 6-1
Class 7400 6-2
General Purpose Dry Type 600 Volts and Below 6-3
K-Rated Transformers 6-3
Drive Isolation Transformers 6-5
Open Core and Coil Transformers 6-6
Industrial Control 6-7
Type EO Transformers 6-7
Type T and MultiTap
TM
Transformers 6-7
Instrument 600 Volt Class 6-8
Voltage and Current Transformers 6-9
Toroidal Current Transformers 6-10
Toroidal Current Transformers (64R, 74R, 66R, 76R) 6-10
Toroidal Current Transformers (110R, 110R, 120R, 140R) 6-10
Toroidal Current Transformers (152R, 170R, 180R, 210R) 6-11
Toroidal Current Transformers (200R, 201R, 202R, 203R) 6-12
Shorting Terminal Blocks 6-12
Current Transformers: Multi-Ratio, Rectangular, Split-Core 6-12
Multi-Ratio Current Transformers 6-12
Rectangular Window Current Transformers 6-13
Split-Core Current Transformers 6-13
Current Transformers: Bushing, Auxiliary 6-14
Bushing Current Transformers 50–400 Hz 6-14
Auxiliary Current Transformers 6-14
Transformers—Obsolete 6-15
Obsolete—January 1, 2016Energy Efficient Three-Phase 6-15
Obsolete—January 1, 2016EE Watchdog Transformers 6-16
Obsolete—January 1, 2016EE NL and NLP Series Transformers 6-17
© 2019 Schneider Electric
All Rights Reserved
TRANSFORMERS
6
6-1
Miscellaneous
Enclosure Dimensions and Accessories
Class 7400
schneider-electric.us
Enclosure
Number/
Style
1 A 5.00 127 4.47 114 3.44 87 Wall
2 A 5.50 140 4.47 114 3.44 87 Wall — 105
3 A 5.00 127 4.85 123 3.75 95 Wall — 105
4 A 5.50 140 5.23 133 4.06 103 Wall — 130
5 A 6.19 157 6.19 157 4.69 119 Wall — 130
6 A 6.69 170 6.19 157 4.69 119 Wall — 180
7 A 8.13 270 6.94 176 5.31 135 Wall — 180
8 A 8.25 210 8.68 220 6.56 167 Wall — 180
9 A 9.56 243 8.68 220 6.56 167 Wall — 180
10 A 10.50 267 8.62 219 6.50 165 Wall — 180
11 A 12.56 319 8.62 219 6.50 165 Wall — 180
12 C 13.50 343 14.75 375 9.00 229 Wall — 180
13 B 14.75 375 9.75 248 11.75 298 Wall — 180
14 C 14.75 375 19.10 485 12.25 311 Wall — 180
15 B 20.00 508 15.00 381 13.50 343 Wall — 180
16 C 22.00 559 25.00 635 13.50 343 Wall — 180
D 27.00 686 20.00 508 16.00 406 Floor WS363 WMB361362 CMB363 220
17
E 27.00 686 20.00 508 16.00 406 Floor
H 37.00 940 20.00 508 16.00 406 Floor WS363 WMB361362 CMB363 220
D 30.00 762 20.00 508 20.00 508 Floor WS363 WMB363364 CMB363 220
18
E 30.00 762 20.00 508 20.00 508 Floor
H 37.00 940 20.00 508 20.00 508 Floor WS363 WMB363364 CMB363 220
D 30.00 762 30.00 762 20.00 508 Floor WS364 WMB363364 CMB364 220
19
E 30.00 762 30.00 762 20.00 508 Floor
D 37.00 940 30.00 762 20.00 508 Floor WS364 WMB363364 CMB364 220
20
E 37.00 940 30.00 762 20.00 508 Floor
D 37.00 940 30.00 762 24.00 610 Floor WS364 — CMB364 220
21
E 37.00 940 30.00 762 24.00 610 Floor
D 43.75 1111 32.00 813 27.00 686 Floor WS380 — CMB380 220
22
E 43.75 1111 32.00 813 27.00 686 Floor
23 E 48 1219 48 1219 29.5 749 Floor
D 49.5 1257 35 889 28.5 724 Floor WS381 — CMB381 220
24
E 49.5 1257 35 889 28.5 724 Floor Note 5 — CMB381 220
D 49.5 1257 41 1041 32 813 Floor WS382 — — 220
25
E 49.5 1257 41 1041 32 813 Floor
26 D 57.5 1461 41 1041 32 813 Floor WS382 — — 220
D 60 1524 56 1422 36 914 Floor WS370A — — 220
28
E 60 1524 56 1422 36 914 Floor
29 D 68 1727 56 1422 36 914 Floor WS370A — — 220
D 71 1803 48 1219 36 914 Floor WS383 — — 220
30
E 71 1803 48 1219 36 914 Floor
D 74 1880 56 1422 40.5 1029 Floor WS384 — — 220
31
E 74 1880 56 1422 40.5 1029 Floor
32 F 91.5 2388 56 1422 54 1372 Floor
33 F 94 2388 72 1829 54 1372 Floor — — 220
34 F 94 2388 84 2134 54 1372 Floor — — 220
35 F 94 2388 96 2438 54 1372 Floor — — 220
36 D 40.5 1031 36.5 916 21.75 553 Floor — — 220
37 D 51.5 1310 40.5 1031 26.5 674 Floor — — 220
38 D 66 1679 50.5 1285 32 814 Floor — — 220
39 F 90 2290 80 2036 50 1272 Floor — — 220
40 F 90 2290 90 2290 50 1272 Floor — — 220
41 F 100 2545 100 2545 60 1527 Floor — — 220
6
42 F 108 2748 108 2748 60 1527 Floor — — 220
43 F 90 2290 64 1628 44 1120 Floor — — 220
44 F 90 2290 72 1832 50 1272 Floor — — 220
45 D 80 2036 64 1628 44 1120 Floor — — 220
51 X 9.5 24 10 25 7.75 20 Wall
52 X 12 30 13.75 35 13.75 35 Wall — 180
53 X 24 61 21.5 55 16.38 42 Wall — 180
54 X 23 58 25.5 65 13.75 35 Wall — 180
TRANSFORMERS
55 X 31.5 80 31.5 80 16.25 41 Wall — 180
61 HX
62 HX
63 HX
Height
In. mm In. mm In. mm
Width
Depth
Contact your local Schneider Electric representative for details.
NOTE: Wall mounting brackets are used with units weighing no more than 700 lbs.
Ceiling mounting brackets are used with units weighing no more than 1200 lbs.
Weathershields are available for units 600 Volts and below. For 2.4, 5, and 15 kV
units suitable for outdoor use, contact the factory.
Mounting
Weather-
shield
[2] [3]
[4]
[4]
[4]
[4]
[4]
[4]
[5]
[4]
[4]
[4]
[4]
[6]
[7] [3]
Wall Mounting
Bracket
WMB361362 CMB363 220
WMB363364 CMB363 220
WMB363364 CMB364 220
WMB363364 CMB364 220
— CMB364 220
— CMB380 220
— — 220
— — 220
— — 220
— — 220
— — 220
— — 220
Ceiling
Mounting
Bracket
Enclosure Dimensions and Accessories [1]
Insulation
Class
— 105
— 180
o
C
[1] These dimensions are not for construction. Contact your local Schneider Electric representative for certified prints.
[2] Transformer is NEMA Type 3R Standard. Weathershield not required for outdoor use.
[3] Wall mounting brackets are a standard part of transformer enclosure. Accessory not required.
[4] Indoor/outdoor enclosure standard. Weathershield not required.
[5] Indoor/outdoor enclosure standard. Weathershield not required.
[6] Special outdoor construction required for NEMA Type 3R applications. Contact your local Schneider Electric representative for details.
[7] Transformer is NEMA Type 4X Standard. Weathershield not required.
6-2
© 2019 Schneider Electric
All Rights Reserved
K-Rated Transformers General Purpose Dry Type 600 Volts and
schneider-electric.us
As a partner in the NEMA Premium Transformer Program, Schneider
Electric has determined that this product meets the NEMA Premium
Efficiency specifications for premium energy efficiency.
Class 7400
Below
Obsolete—October 1, 2015
K-Rated, Three-Phase (15–1000 kVA)
K-rated transformers mitigate Triplen harmonics via a Delta-Wye configuration.
Aluminum or copper windings
•
Isolation transformer with electrostatic shield
•
K-4 and K-13 levels
•
Harmonic Mitigating, Three-Phase (15–1000 kVA)
Harmonic Mitigating transformers mitigate Triplen harmonics via electromagnetic phase
relations. They remove 5th and 7th harmonics when using dual devices with a 0° and a
+30° phase shift. They further reduce 11th and 13th harmonics when a +15° or -15° shift
is added to the dual devices. Available with:
Aluminum or copper windings
•
Isolation transformer
•
NEMA Premium
Table 6.1: 480 V Delta Primary, 208Y/120 Secondary
kVA
NP Series for Typical Non-Linear Load Service— K-9 Rated—Copper Windings; 130 °C Rise
15 EP15T3HNISCUNP 6–2.5% 2+4– 310 17D
30 EP30T3HNISCUNP 6–2.5% 2+4– 340 18D
45 EP45T3HNISCUNP 6–2.5% 2+4– 418 20D
75 EP75T3HNISCUNP 6–2.5% 2+4– 642 21D
112.5 EP112T3HNISCUNP 6–2.5% 2+4– 725 22D
150 EP150T3HNISCUNP 6–2.5% 2+4– 915 24D
225 EP225T3HNISCUNP 6–2.5% 2+4– 1125 25D
300 EP300T3HNISCUNP 4–2.5% 2+2– 1535 30D
NP Series for Typical Non-Linear Load Service— K-9Rated—Copper Windings; 115 °C Rise
15 EP15T3HFISCUNP 6–2.5% 2+4– 310 17D
30 EP30T3HFISCUNP 6–2.5% 2+4– 340 18D
45 EP45T3HFISCUNP 6–2.5% 2+4– 418 20D
75 EP75T3HFISCUNP 6–2.5% 2+4– 642 20D
112.5 EP112T3HFISCUNP 6–2.5% 2+4– 725 22D
150 EP150T3HFISCUNP 6–2.5% 2+4– 915 24D
225 EP225T3HFISCUNP 6–2.5% 2+4– 1125 25D
300 EP300T3HFISCUNP 4–2.5% 2+2– 1535 25D
NLP Series for More Severe Non-Linear Load Service—K-13 Rated—Copper Windings; 150 °C Rise
15 EP15T3HISCUNLP 6–2.5% 2+4– 260 17D
30 EP30T3HISCUNLP 6–2.5% 2+4– 430 18D
45 EP45T3HISCUNLP 6–2.5% 2+4– 730 20D
75 EP75T3HISCUNLP 6–2.5% 2+4– 640 20D
112.5 EP112T3HISCUNLP 6–2.5% 2+4– 985 22D
150 EP150T3HISCUNLP 6–2.5% 2+4– 1135 24D
225 EP225T3HISCUNLP 6–2.5% 2+4–
300 EP300T68HISCUNLP 4–2.5% 2+2– 2650 30D
Catalog No. Taps Weight (lbs)
1477 25D
Enclosure
© 2019 Schneider Electric
All Rights Reserved
TRANSFORMERS
6
6-3
General Purpose Dry Type 600 Volts and
Below
K-Rated Transformers
Class 7400
Obsolete—October 1, 2015
Table 6.2: Harmonic Mitigating, 480 Primary to 208zz/120 Secondary;
Copper Windings
kVA
0° Phase Shift
15 HM15T208HNCUEP 6–2.5% 2+4– 310 17D
30 HM30T208HNCUEP 6–2.5% 2+4– 340 17D
45 HM45T208HNCUEP 6–2.5% 2+4– 418 18D
75 HM75T208HNCUEP 6–2.5% 2+4– 642 20D
112.5 HM112T208HNCUEP 6–2.5% 2+4– 725 21D
150 HM150T208HNCUEP 6–2.5% 2+4– 915 22D
225 HM225T208HNCUEP 6–2.5% 2+4– 1125 24D
300 HM300T208HNCUEP 6–2.5% 2+4– 1535 25D
30° Phase Shift
15 HM15T255HNCUEP 3-5%1+2- 310 17D
30 HM30T255HNCUEP 3-5%1+2- 340 17D
45 HM45T255HNCUEP 3-5%1+2- 418 18D
75 HM75T255HNCUEP 3-5%1+2- 642 20D
112.5 HM112T255HNCUEP 3-5%1+2- 725 21D
150 HM150T255HNCUEP 3-5%1+2- 915 22D
225 HM225T255HNCUEP 3-5%1+2- 1125 24D
300 HM300T255HNCUEP 3-5%1+2- 1535 25D
+15° Phase Shift
15 HM15T251HNCUEP 6–2.5% 2+4– 310 17D
30 HM30T251HNCUEP 6–2.5% 2+4– 340 17D
45 HM45T251HNCUEP 6–2.5% 2+4– 418 18D
75 HM75T251HNCUEP 6–2.5% 2+4– 642 20D
112.5 HM112T251HNCUEP 6–2.5% 2+4– 725 21D
150 HM150T251HNCUEP 6–2.5% 2+4– 915 22D
225 HM225T251HNCUEP 6–2.5% 2+4– 1125 24D
300 HM300T251HNCUEP 6–2.5% 2+4– 1535 25D
-15° Phase Shift
15 HM15T259HNCUEP 6–2.5% 2+4– 310 17D
30 HM30T259HNCUEP 6–2.5% 2+4– 340 17D
45 HM45T259HNCUEP 6–2.5% 2+4– 418 18D
75 HM75T259HNCUEP 6–2.5% 2+4– 642 20D
112.5 HM112T259HNCUEP 6–2.5% 2+4– 725 21D
150 HM150T259HNCUEP 6–2.5% 2+4– 915 22D
225 HM225T259HNCUEP 6–2.5% 2+4– 1125 24D
300 HM300T259HNCUEP 6–2.5% 2+4– 1535 25D
Additional temperature rises are available; for part numbers, see the Schneider Electric
Product Configurator.
Catalog
No.
Taps Weight (lbs)
schneider-electric.us
Enclosure
6
TRANSFORMERS
6-4
© 2019 Schneider Electric
All Rights Reserved
Drive Isolation Transformers General Purpose Dry Type 600 Volts and
schneider-electric.us
Class 7400
Drive Isolation Transformers
Special design considerations must be made for the requirements of both adjustable
frequency and dc motor drive power isolation. Allowance for high surge, harmonic and
offset currents are taken into account in the design of Square D
transformers. Drive isolation transformers are not shielded isolation transformers, but act
to lessen transient generation into the supply power and act as a buffer for SCR current
surges.
Table 6.3: Three-Phase 60 Hz; Class B
(IEEE Standard 597-1983); 460 V Delta Primary
kVA
460 V Delta Primary, 460Y/265 V Secondary, 150 °C Rise
7.5 7T145HDIT 2–5%1 + 1– 180 17D
11 11T145HDIT 2–5%1 + 1– 180 17D
15 15T145HDIT 2–5%1 + 1– 190 17D
20 20T145HDIT 2–5%1 + 1– 210 17D
27 27T145HDIT 2–5%1 + 1– 250 17D
34 34T145HDIT 2–5%1 + 1– 295 18D
40 40T145HDIT 2–5%1 + 1– 350 18D
51 51T145HDIT 2–5%1 + 1– 445 20D
63 63T145HDIT 2–5%1 + 1– 465 20D
75 75T145HDIT 2–5%1 + 1– 550 20D
93 93T145HDIT 2–5%1 + 1– 845 22D
118 118T145HDIT 2–5%1 + 1– 920 22D
145 145T145HDIT 2–5%1 + 1– 1025 22D
175 175T145HDIT 2–5%1 + 1– 1120 25D
220 220T145HDIT 2–5%1 + 1– 1200 25D
275 275T145HDIT 2–5%1 + 1– 1500 25D
330 330T145HDIT 2–5%1 + 1– 1390 25D
440 440T145HDIT 2–5%1 + 1– 2700 30D
550 550T145HDIT 2–5%1 + 1– 3800 30D
460 V Delta Primary, 230Y/132 V Secondary, 150 °C Rise
7.5 7T144HDIT 2–5%1 + 1– 180 17D
11 11T144HDIT
15 15T144HDIT 2–5%1 + 1– 190 17D
20 20T144HDIT 2–5%1 + 1– 210 17D
27 27T144HDIT
34 34T144HDIT 2–5%1 + 1– 295 18D
40 40T144HDIT 2–5%1 + 1– 350 18D
51 51T144HDIT 2–5%1 + 1– 445 20D
63 63T144HDIT 2–5%1 + 1– 465 20D
75 75T144HDIT 2–5%1 + 1– 550 20D
93 93T144HDIT 2–5%1 + 1– 845 22D
118 118T144HDIT 2–5%1 + 1– 920 22D
145 145T144HDIT 2–5%1 + 1– 1025 22D
175 175T144HDIT 2–5%1 + 1– 1120 25D
220 220T144HDIT 2–5%1 + 1– 1200 25D
275 275T144HDIT 2–5%1 + 1– 1500 25D
330 330T144HDIT 2–5%1 + 1– 1390 25D
440 440T144HDIT 2–5%1 + 1– 2700 30D
550 550T144HDIT 2–5%1 + 1– 3800 30D
Catalog
No.
Full Capacity Taps Weight (lbs) [1]
2–5%1 + 1– 180 17D
2–5%1 + 1– 250 17D
Enclosure
[1][2]
™
brand drive isolation
Table 6.4: Three-Phase 60 Hz; Class B
(IEEE Standard 597-1983); 230 V Delta Primary
kVA
230 V Delta Primary, 460Y/265 V Secondary, 150 °C Rise
7.5 7T143HDIT 2–5%1 + 1– 180 17D
11 11T143HDIT 2–5%1 + 1– 180 17D
15 15T143HDIT 2–5%1 + 1– 190 17D
20 20T143HDIT 2–5%1 + 1– 210 17D
27 27T143HDIT 2–5%1 + 1– 250 17D
34 34T143HDIT 2–5%1 + 1– 295 18D
40 40T143HDIT 2–5%1 + 1– 350 18D
51 51T143HDIT 2–5%1 + 1– 445 20D
63 63T143HDIT 2–5%1 + 1– 465 20D
75 75T143HDIT 2–5%1 + 1– 550 20D
93 93T143HDIT 2–5%1 + 1– 845 22D
118 118T143HDIT 2–5%1 + 1– 920 22D
145 145T143HDIT 2–5%1 + 1– 1025 22D
175 175T143HDIT 2–5%1 + 1– 1120 25D
220 220T143HDIT 2–5%1 + 1– 1200 25D
275 275T143HDIT 2–5%1 + 1– 1500 25D
330 330T143HDIT 2–5%1 + 1– 1390 25D
440 440T143HDIT 2–5%1 + 1– 2700 30D
550 550T143HDIT 2–5%1 + 1– 3800 30D
230 V Delta Primary, 230Y/132 V Secondary, 150 °C Rise
7.5 7T142HDIT
11 11T142HDIT 2–5%1 + 1– 180 17D
15 15T142HDIT 2–5%1 + 1– 190 17D
20 20T142HDIT 2–5%1 + 1– 210 17D
27 27T142HDIT 2–5%1 + 1– 250 17D
34 34T142HDIT 2–5%1 + 1– 295 18D
40 40T142HDIT 2–5%1 + 1– 350 18D
51 51T142HDIT 2–5%1 + 1– 445 20D
63 63T142HDIT 2–5%1 + 1– 465 20D
75 75T142HDIT 2–5%1 + 1– 550 20D
93 93T142HDIT 2–5%1 + 1– 845 22D
118 118T142HDIT 2–5%1 + 1– 920 22D
145 145T142HDIT 2–5%1 + 1– 1025 22D
175 175T142HDIT 2–5%1 + 1– 1120 25D
220 220T142HDIT 2–5%1 + 1– 1200 25D
275 275T142HDIT 2–5%1 + 1– 1500 25D
330 330T142HDIT 2–5%1 + 1– 1390 25D
440 440T142HDIT 2–5%1 + 1– 2700 30D
550 550T142HDIT 2–5%1 + 1– 3800 30D
Catalog
No.
Full Capacity
Taps
2–5%1 + 1– 180 17D
Weight (lbs)
[1]
NOTE: Lugs are furnished by customer.
Below
Enclosure
[1][2]
[1] Not for construction. Contact your nearest Schneider Electric sales office for certified prints.
[2] For enclosure styles, see the dimensions table in Digest Section for Transformers.
© 2019 Schneider Electric
All Rights Reserved
TRANSFORMERS
6
6-5
General Purpose Dry Type 600 Volts and
Below
Open Core and Coil Transformers
Class 7400 / Refer to Catalog 7400CT9601
schneider-electric.us
Open Core and Coil Transformers Designed for General
Applications for 600 V and Below
Units are designed with 220 °C insulation, aluminum windings, top terminations, compact
design to save space, and are UL component recognized for:
Non-energy efficiency (less than 15 kVA)
•
Single-phase 5–10 VA
Three-phase 3–9 VA
Energy efficiency (meets Table 4-2 of NEMA TP1–2002)
•
Single-phase 15–75 kVA
Three-phase 15–112.5 kVA
Figure 1
Figure 2
Figure 3
Table 6.5: Single-Phase Open Core and Coil Transformers—240 X 480 V Primary, 120/240 V Secondary, 60 Hz
kVA
5 5S1HFOC 115 — 8.00 203 9.00 229 11.00 279 8.00 203 8.00 203 66 1
7.5 7S1HFOC 115 — 8.00 203 9.00 229 14.25 362 8.00 203 8.50 216 80 1
10 10S1HFOC 115 — 20.50 521 18.5 470 14.00 356 17.0 432 4.25 108 140 2
15 EE15S3HOC 150
25 EE25S3HOC 150
37.5 EE37S3HOC 150
50 EE50S3HOC 150
75 EE75S3HOC 150
Catalog
No.
Deg.
C
Temp.
Rise
Full Capacity Taps
6–2.5% 2+4–[5]
6–2.5% 2+4–[5]
6–2.5% 2+4–[5]
6–2.5% 2+4–[5]
6–2.5% 2+4–[5]
A B C D
in mm in mm in mm in mm in mm
20.50 521 18.5 470 14.00 356 17.0 432 4.25 108 140 2
20.25 514 18.5 470 14.00 356 17.0 432 5.00 127 200 2
22.00 559 18.5 470 18.00 457 17.0 432 5.50 140 255 2
22.00 559 18.5 470 18.00 457 17.0 432 6.50 165 310 2
22.25 565 28.0 711 22.00 559 27.0 686 8.50 216 460 2
Dimensions [3]
E[4]
6
TRANSFORMERS
Weig-
ht
(lbs)
Figure
[3] Not for construction. Contact your nearest Schneider Electric sales office for certified prints.
[4] Dimensions may vary due to manufacturing process.
[5] When 240 V tap is used, there will be 3–5% taps, 1 above and 2 below.
6-6
© 2019 Schneider Electric
All Rights Reserved
Type EO Transformers Industrial Control
Class 9070 / Refer to Catalog 9070CT9901
schneider-electric.us
Table 6.6: Regulation Chart for Type EO
Transformers
VA (60
Hz)
100 479 606 770 346 463 613
150 755 1177 1532 567 930 1252
200 1260 1883 2419 910 1462 1950
250 1530 2327 2995 1115 1811 2419
300 2030 2981 3800 1455 2290 3038
350 2920 4586 5981 2180 3637 4903
500 4230 5984 7707 3120 4661 6229
750 7430 11460 14736 5380 8907 11891
1000 10300 16873 21734 7450 13145 17571
1500 19200 30042 39217 14500 23859 32179
2000 27750 45194 60022 21750 36901 50994
3000 31800 82333 108205 26750 66072 89509
5000 86100 148768 202077 72600 126887 175552
Inrush UL VA at 20%
Power Factor
95% 90% 85% 95% 90% 85%
25 95 — 146 60 — 119
50 164 213 277 123 168 225
75 387 487 622 284 375 798
Secondary Voltage
Inrush UL VA at 40%
Power Factor
Type EO Transformers
Type EO units are designed with exceptional voltage regulation. These control
transformers are constructed using traditional materials and manufacturing techniques,
and are designed for 25–5000 VA with a 55 °C temperature rise. When exceptional
regulation and very low temperature rise are an absolute necessity, choose Type EO
units.
Table 6.7: Type EO Transformer Dimensions
VA (60 Hz)
220x440 V Primary, 110 V Secondary; 230x460 V Primary, 115 V Secondary; or
240x480 V Primary, 120 V Secondary
100 9070EO2D1 3.78 96 3.38 86 2.81 71 3.8 1.7
150 9070EO3D1 4.44 113 3.75 95 3.13 80 6.0 2.7
200 9070EO19D1 4.81 122 4.50 114 3.75 95 10.5 4.8
250 9070EO15D1 5.19 132 4.50 114 3.75 95 13.2 6.0
300 9070EO04D1 5.56 141 4.50 114 3.75 95 17.2 7.8
500 9070EO51D1 6.56 167 5.25 133 4.38 111 24.5 11.1
750 9070EO61D1 7.94 202 5.25 133 4.38 111 30.5 13.8
1000 9070EO71D1 7.94 202 6.00 152 5.00 127 45.0 20.4
1500 9070EO81D1 8.59 218 7.06 179 6.03 153 56.0 25.4
2000 9070EO91D1 9.22 234 7.06 179 6.03 153 72.0 32.7
3000 9070EO10D1 9.44 239 9.00 229 7.50 191 115.0 52.2
240x480 V Primary, 24 V Secondary
100 9070EO2D2 3.78 96 3.38 86 2.81 71 3.8 1.7
250 9070EO16D2 6.19 157 4.50 114 3.75 95 13.2 6.0
550 V Primary, 110 V Secondary; 575 V Primary, 115 V Secondary; or 600 V Primary, 120 V Secondary
200 9070EO19D5 5.56 4.81 122 4.50 114 3.75 10.5 4.8
300 9070EO04D5 5.56 141 4.50 114 3.75 95 17.2 7.8
500 9070EO51D5 6.56 167 5.25 133 4.38 111 24.5 11.1
750 9070EO61D5 7.94 202 5.25 133 4.38 111 30.5 13.8
Catalog Number
Class 9070
25 9070EO17D1 3.31 84 3.00 76 2.50 64 1.9 0.9
50 9070EO1D1 3.31 84 3.00 76 2.50 64 2.2 1.0
75 9070EO18D1 3.78 96 3.38 86 2.81 71 3.5 1.6
25 9070EO17D2 3.31 84 3.00 76 2.50 64 1.9 0.9
50 9070EO10D2 3.31 84 3.00 76 2.50 64 2.2 1.0
75 9070EO18D2 3.78 96 3.38 86 2.81 71 3.5 1.6
A B C
IN mm IN mm IN mm lbs
Weight
kg
Type T and MultiTap™ Transformers
Table 6.8: Regulation Chart for Type T
Transformers
VA
(60 Hz)
100 339 499 659 266 404 549
150 666 893 1120 529 731 942
200 588 815 1041 459 659 866
250 1416 1910 2388 1057 1494 1936
300 1634 2184 2709 1194 1681 2169
350 1894 2592 3261 1392 2005 621
500 3197 4104 4981 2374 3195 4019
750 3770 5515 7231 2887 4391 5945
1000 6587 9079 11430 4706 6886 9051
1500 19324 23983 28607 15066 19361 23756
2000 31384 38777 6161 24794 31630 38667
3000 26539 39934 52713 19355 30721 42216
5000 53111 85265 116277 39368 66309 93882
Inrush UL VA at 20%
Power Factor
95% 90% 85% 95% 90% 85%
50 193 266 339 151 215 282
75 271 396 20 210 318 430
Secondary Voltage
Inrush UL VA at 40%
Power Factor
Table 6.9: Type T Transformer Selection
UL/CSA/NOM CE
120 V Primary, 120 V Secondary; 115 V Primary, 115 V Secondary; or 110 V Primary, 110 V Secondary
© 2019 Schneider Electric
All Rights Reserved
VA
50 50 9070T50D24
75 75 9070T75D24
100 100 9070T100D24
150 150 9070T150D24
200 200 9070T200D24
250 160 9070T250D24
300 200 9070T300D24
350 250 9070T350D24
500 300 9070T500D24
750 500 9070T750D24
1000 630 9070T1000D24
1500 1000 9070T1500D24
2000 1500 9070T2000D24
Catalog No.
Type T transformers are designed with low impedance windings for excellent voltage
regulation and can accommodate the high inrush current associated with contactors,
starters, solenoids, and relays. As the most popular and complete line of control
transformers with unmatched design innovations for top performance, Type Ts are
manufactured using the most advanced insulating materials and are the best choice if
size and cost are of concern. It is available in the MultiTap version, designed to respond
to the increased need for voltage and stock flexibility. It combines multiple primary
voltages with one or more secondary voltages, all in a single transformer.
Selection Guide
1. Determine the inrush and sealed VA of each coil in the control circuit, and the VA of
all other components.
2. Total the sealed VA of all operating coils and the VA of all other loads. (This
determines the minimal VA size required for the circuit.)
3. Total the inrush VA of all coils that are starting at the same time, and all loads and
coils that are running. (Use the regulation chart to give possible units to be used.)
4. Taking the VA size from step 2, go to the standard VA size in the chart. Make sure
the inrush VA from the chart is greater than the total VA from step 3. (If not, go to the
next larger VA size and repeat.)
If your supply voltage is stable and fluctuates less than 5%, we recommend you use the
90% secondary voltage column. If your supply voltage is not stable and fluctuates more
than 10%, we recommend you use the 95% secondary voltage column. We recommend
that you never use the 85% secondary voltage column since magnetic devices lose life
expectancy if they are continuously started at 85% of rated voltage.
H W D
in (mm) in (mm) in (mm)
2.58 (65.5) 3.00 (76.2) 3.09 (78.5)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.25 (82.6) 3.75 (95.3) 5.25 (133.4)
3.80 (96.5) 4.50 (114.3) 4.70 (119.4)
3.80 (96.5) 4.50 (114.3) 5.09 (129.3)
3.80 (96.5) 4.50 (114.3) 5.46 (138.7)
4.43 (112.5) 5.25 (133.4) 5.66 (143.8)
4.43 (112.5) 5.25 (133.4) 6.04 (153.4)
6.16 (156.5) 7.06 (179.3) 5.81 (147.6)
6.16 (156.5) 7.06 (179.3) 7.04 (178.8)
Weight
(lbs)
2.5
3.8
3.8
5.5
5.5
7.1
8.5
10.5
11.9
11.0
20.6
34.0
47.0
TRANSFORMERS
6
6-7
Instrument 600 Volt Class Type T and MultiTap TMTransformers
Class 9070 / Refer to Catalogs 9070CT9901, 7400CT9601
Table 6.9 Type T Transformer Selection (cont'd.)
UL/CSA/NOM CE
120 V x 240 V Primary, 120/240 V Secondary; 115 V x 230 V Primary, 115/230 V Secondary; or 110 V x 220 V Primary, 110/220 V Secondary
277 V Primary, 24 V Secondary
600 V Primary, 12/24 V Secondary
480 V Primary, 240 V Secondary; 460 V Primary, 230 V Secondary; or 440 V Primary, 220 V Secondary
6
TRANSFORMERS
VA
3000 2000 9070T3000D24
5000 3000 9070T5000D24
50 50 9070T50D55
75 75 9070T75D55
100 100 9070T100D55
150 150 9070T150D55
200 200 9070T200D55
250 160 9070T250D55
300 200 9070T300D55
350 250 9070T350D55
500 300 9070T500D55
750 500 9070T750D55
1000 630 9070T1000D55
1500 1000 9070T1500D55
2000 1500 9070T2000D55
3000 2000 9070T3000D55
5000 3000 9070T5000D55
50 50 9070T50D25
75 75 9070T75D25
100 100 9070T100D25
150 150 9070T150D25
200 200 9070T200D25
250 160 9070T250D25
300 200 9070T300D25
350 250 9070T350D25
500 300 9070T500D25
750 500 9070T750D25
1000 630 9070T1000D25
50 50 9070T50D36
75 75 9070T75D36
100 100 9070T100D36
150 150 9070T150D36
200 200 9070T200D36
250 160 9070T250D36
300 200 9070T300D36
350 250 9070T350D36
500 300 9070T500D36
750 500 9070T750D36
1000 630 9070T1000D36
50 50 9070T50D12
75 75 9070T75D12
100 100 9070T100D12
150 150 9070T150D12
200 200 9070T200D12
250 160 9070T250D12
300 200 9070T300D12
350 250 9070T350D12
500 300 9070T500D12
750 500 9070T750D12
1000 630 9070T1000D12
1500 1000 9070T1500D12
2000 1500 9070T2000D12
3000 2000 9070T3000D12
5000 3000 9070T5000D12
Catalog No.
H W D
in (mm) in (mm) in (mm)
8.46 (214.9) 9.00 (228.6) 6.86 (174.2)
8.46 (214.9) 9.00 (228.6) 8.73 (221.7)
2.58 (65.5) 3.00 (76.2) 3.09 (78.5)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.20 (81.3) 3.75 (95.3) 3.59 (91.20)
3.25 (82.6) 3.75 (95.3) 5.25 (133.4)
3.80 (96.5) 4.50 (114.3) 4.70 (119.4)
3.80 (96.5) 4.50 (114.3) 5.09 (129.3)
3.80 (96.5) 4.50 (114.3) 5.46 (138.7)
4.43 (112.5) 5.25 (133.4) 5.66 (143.8)
4.43 (112.5) 5.25 (133.4) 6.04 (153.4)
6.16 (156.5) 7.06 (179.3) 5.81 (147.6)
6.16 (156.5) 7.06 (179.3) 7.04 (178.8)
8.46 (214.9) 9.00 (228.6) 6.86 (174.2)
8.46 (214.9) 9.00 (228.6) 8.73 (221.7)
2.58 (65.5) 3.00 (76.2) 3.09 (78.5)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.20 (81.3) 3.75 (95.3) 3.59 (91.20)
3.25 (82.6) 3.75 (95.3) 5.25 (133.4)
3.80 (96.5) 4.50 (114.3) 4.70 (119.4)
3.80 (96.5) 4.50 (114.3) 5.09 (129.3)
3.80 (96.5) 4.50 (114.3) 5.46 (138.7)
4.43 (112.5) 5.25 (133.4) 5.66 (143.8)
4.43 (112.5) 5.25 (133.4) 6.04 (153.4)
2.58 (65.5) 3.00 (76.2) 3.09 (78.5)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.20 (81.3) 3.75 (95.3) 3.59 (91.20)
3.25 (82.6) 3.75 (95.3) 5.25 (133.4)
3.80 (96.5) 4.50 (114.3) 4.70 (119.4)
3.80 (96.5) 4.50 (114.3) 5.09 (129.3)
3.80 (96.5) 4.50 (114.3) 5.46 (138.7)
4.43 (112.5) 5.25 (133.4) 5.66 (143.8)
4.43 (112.5) 5.25 (133.4) 6.04 (153.4)
2.58 (65.5) 3.00 (76.2) 3.09 (78.5)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
2.89 (73.4) 3.38 (85.8) 3.34 (84.8)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.20 (81.3) 3.75 (95.3) 3.59 (91.2)
3.25 (82.6) 3.75 (95.3) 5.25 (133.4)
3.80 (96.5) 4.50 (114.3) 4.70 (119.4)
3.80 (96.5) 4.50 (114.3) 5.09 (129.3)
3.80 (96.5) 4.50 (114.3) 5.46 (138.7)
4.43 (112.5) 5.25 (133.4) 5.66 (143.8)
4.43 (112.5) 5.25 (133.4) 6.04 (153.4)
6.16 (156.5) 7.06 (179.3) 5.81 (147.6)
6.16 (156.5) 7.06 (179.3) 7.04 (178.8)
8.46 (214.9) 9.00 (228.6) 6.86 (174.2)
8.46 (214.9) 9.00 (228.6) 8.73 (221.7)
schneider-electric.us
Weight
(lbs)
60.0
89.0
2.5
3.8
3.8
5.5
5.5
7.1
8.5
10.5
11.9
11.0
20.6
34.0
47.0
60.0
89.0
2.5
3.8
3.8
5.5
5.5
7.1
8.5
10.5
11.9
11.0
20.6
2.5
3.8
3.8
5.5
5.5
7.1
8.5
10.5
11.9
11.0
20.6
2.5
3.8
3.8
5.5
5.5
7.1
8.5
10.5
11.9
11.0
20.6
34.0
47.0
60.0
89.0
6-8
© 2019 Schneider Electric
All Rights Reserved
schneider-electric.us
A
CEB
H1
0.20 Dia.
Mtg. Hole
(2)
D
Model 450R
Voltage and Current Transformers Instrument 600 Volt Class
Class 4210 / Refer to Catalog 4210CT9701
Voltage Transformers
These voltage transformers are designed for line-to-line or line-to-ground connection on
the primary voltage indicated. See Table 6.10 Voltage Transformers, UR/cUR
Recognized, 60 Hz, page 6-9 to determine the applicable configuration for proper system
voltage indication.
Model 450R —designed for switchboard use. This model features high accuracy and
•
burden capacity for excellent performance in metering and indication.
Model 460R —a compact, lightweight design, providing exceptional performance in
•
indicating applications.
Model 470R —a compact, low cost design optimized for maximum accuracy and
•
performace when used with Powerlogic™ circuit monitors.
Table 6.10: Voltage Transformers, UR/cUR Recognized, 60 Hz
Model 460R
Model 470R
Model 450R
Thermal Rating:
500 VA @ 30
300 VA @ 55
Accuracy 0.3W. X.M & Y:
Catalog Number Catalog Number Catalog Number
Model
450R
460R
470R
1.2 Z
450R069
450R120
450R208
450R240
450R288
450R300
450R380
450R480
450R600
o
C;
o
C.
Model 460R
Thermal Rating:
150 VA @ 30
100 VA @ 55
Accuracy 0.6W: 1.2 X
o
C;
o
C.
460R069
460R120
460R208
460R240
460R288
460R300
460R380
460R480
460R600
A B C
6
4–3/4
4–3/4
Model 470R
Thermal Rating:
150 VA @ 30
100 VA @ 55
Accuracy 0.3W: 1.2 X
o
C;
o
C.
470R069
470R120
470R208
470R240
470R288
470R300
470R380
470R480
470R600
Dimensions (inches)
7–1/8
4–1/2
4–1/2
System
Voltage
69/120Y
120/208Y
120/208Y
240/416Y
288/500Y[1]
300/520Y
220/380Y
480/480Y[2]
600/600Y
5–7/8
3–7/8
3–7/8
Winding
Ratio
0.58:1
1:1
1.73:1
2:1
2.4:1
2.5:1
3.17:1
4:1
5:1
Model 54R
Table 6.11: Dimensions for Models 2NR, 5NR, 54R,
and 7RL
Model
2NR
5NR
54R
7RL
A B C D E
1.13
1.56
1.56
2.25
Dimensions (inches)
2.38
3.50
3.50
4.38
—
—
4.56
—
.94
1.06
1.06
1.38
—
—
4.00
—
Current Transformers
Table 6.12: General Purpose Compact Units, UR/cUR Recognized
Window
Size
(inches)
1-1/8
1-9/16
1-9/16
2-1/4
Catalog Number
(without brackets)
2NR500
2NR600
2NR750
2NR800
2NR101
2NR121
2NR1250
2NR151
2NR201
2NR251
2NR301
5NR101
5NR151
5NR201
5NR251
5NR301
5NR401
5NR501
5NR601
54R101
54R151
54R201
54R251
54R301
54R401
54R501
54R601
7RL500
7RL101
7RL151
7RL201
7RL251
7RL301
7RL401
7RL501
7RL601
7RL751
7RL801
7RL102
7RL122
7RL152
Current
Rating
(Amperes)
50:5
60:5
75:5
80:5
100:5
120:5
125:5
150:5
200:5
250:5
300:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
50:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
VA 60HzVA 400
12.5
12.5
25.0
12.5
12.5
25.0
12.5
12.5
12.5
12.5
12.5
25.0
25.0
25.0
1.0
1.0
1.5
1.5
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.0
2.5
5.0
5.0
5.0
2.0
2.5
5.0
5.0
5.0
2.5
2.5
2.5
5.0
5.0
5.0
Hz
2.0
2.0
3.0
3.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
4.0
5.0
12.5
12.5
12.5
25.0
25.0
50.0
4.0
5.0
12.5
12.5
12.5
25.0
25.0
50.0
5.0
5.0
5.0
10.0
10.0
10.0
25.0
25.0
25.0
25.0
25.0
50.0
50.0
50.0
Accuracy
(At Rated Current)
= 2%
= 2%
= 2%
= 2%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
= 1%
Rating
Factor
o
C Ambient
30
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
TRANSFORMERS
6
[1] For use on 277/480 Wye systems.
[2] For use on 480 V Delta systems.
© 2019 Schneider Electric
All Rights Reserved
6-9
Instrument 600 Volt Class Toroidal Current Transformers
Class 4210 / Refer to Catalog 4210CT9701
Toroidal Current Transformers (64R, 74R, 66R, 76R)
Table 6.14: Toroidal Current Transformers, UR/cUR Recognized, 25–400 Hz
Models 64R, 74R
Models 66R, 76R
Models 64R, 66R, 74R, 76R,
Table 6.13: Dimensions for 64R, 66R, 74R, and 76R
Model
64R
66R
74R
76R
Dimensions (inches)
A B C
1-15/16
1-15/16
2-11/32
2-11/32
4-3/16
4-3/16
4-11/16
4-11/16
1-1/2
31/16
1-5/8
3-1/4
Window
Size
(inches)
1-15/16
1-15/16
2-11/32
2-11/32
Catalog
Number
(without
brackets) [3]
64R101
64R151
64R201
64R251
64R301
64R401
64R501
64R601
64R751
66R101
66R151
66R201
66R251
66R301
66R401
66R501
66R601
66R751
74R201
74R251
74R301
74R401
74R501
74R601
74R751
74R801
74R102
74R122
74R152
76R201
76R251
76R301
76R401
76R501
76R601
76R751
76R801
76R102
76R122
76R152
Current
Rating
(Amperes)
100:5
150:0
200:5
250:5
300:5
400:5
500:5
600:5
750:5
100:5
150:0
200:5
250:5
300:5
400:5
500:5
600:5
750:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
Relay
Class
—
—
—
—
—
—
—
—
—
—
—
C10
C10
C10
C10
C20
C20
C20
—
—
—
—
—
—
—
—
—
—
—
C10
C10
C10
C10
C10
C20
C20
C20
C20
C20
C20
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
1.2
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Metering Class
2.4
1.2
1.2
0.6
0.6
0.6
0.3
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
1.2
0.6
0.6
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.6
0.6
1.2
0.6
0.6
0.3
0.6
0.3
0.3
0.3
0.3
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
schneider-electric.us
Rating
Factor
o
30
C
Ambient
1.33
—
—
—
—
—
—
—
2.4
1.2
0.6
0.6
0.6
—
—
2.4
2.4
1.2
1.2
0.6
0.6
0.3
0.3
—
1.2
2.4
1.2
0.6
0.6
0.6
0.6
0.3
0.3
0.3
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
2.4
2.4
1.2
0.6
0.6
0.3
1.2
1.2
1.2
1.2
0.6
0.6
0.6
2.4
2.4
1.2
1.2
0.6
0.6
0.6
0.3
0.3
0.3
0.3
1.33
—
1.33
—
1.33
—
1.33
—
1.33
—
1.33
—
1.33
1.33
—
1.33
—
1.33
—
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
—
1.33
—
1.33
—
1.33
—
1.33
1.33
1.33
1.33
1.33
1.33
1.00
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.00
6
Models 100R, 110R, 120R, 140R
TRANSFORMERS
100R, 110R, 120R, and 140R
Table 6.15: Dimensions for 100R, 110R, 120R, and
140R
Model
100R
110R
120R
140R
Dimensions (inches)
A B C
4
4
5-3/4
8-1/8
7
7
8-1/2
11
2-1/8
2-7/8
2-1/8
Toroidal Current Transformers (110R, 110R, 120R, 140R)
Table 6.16: Toroidal Current Transformers, UR/cUR Recognized, 25–400 Hz
Window
Size
(inches)
5-3/4
3
Catalog
Number
(without
brackets)
[3]
100R201
100R301
100R401
100R501
100R601
100R801
4
100R102
100R122
100R152
100R162
100R202
110R201
110R301
110R401
110R501
110R601
110R801
4
110R102
110R122
110R152
110R162
110R202
120R201
120R301
120R401
120R501
120R601
120R801
120R102
120R122
120R152
120R162
120R202
120R252
120R302
120R402
Current
Rating
(Amperes)
200:5
300:5
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
200:5
300:5
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
200:5
300:5
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
3000:5
4000:5
Relay
Class
C10
C10
C20
C20
C20
C20
C50
C50
C50
C50
C50
C20
C20
C20
C50
C50
C50
C100
C100
C100
C100
C100
C10
C10
C20
C20
C20
C20
C50
C50
C50
C50
C50
C50
C50
—
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Metering Class
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
—
—
2.4
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
—
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
—
—
—
2.4
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Rating
Factor
o
C
30
Ambient
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.00
[3] For mounting brackets, refer to Bushing Current Transformers 50–400 Hz, page 6-14
6-10
© 2019 Schneider Electric
All Rights Reserved
Toroidal Current Transformers Instrument 600 Volt Class
Class 4210 / Refer to Catalog 4210CT9701
schneider-electric.us
Models 152R, 170R, 180R, 210R
Table 6.17: Dimensions for Models 152R, 170R,
180R, and 210R
Model
152R
170R
180R
210R
Dimensions (inches)
A B C
6.88
4.25
2.50
6.25
12.25
6.75
4.50
9.50
4.12
1.31
2.12
2.87
Table 6.16 Toroidal Current Transformers, UR/cUR Recognized, 25–400 Hz
(cont'd.)
Window
Size
(inches)
8-1/8
8-1/8
Catalog
Number
(without
brackets)
[4]
140R500 50:5 —
140R101 100:5 — — — 1.33
140R401
140R501
140R601
140R801
140R102
140R122
140R152
140R202
140R252
140R302
140R402
140R502
140R602
Current
Rating
(Amperes)
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
2000:5
2500:5
3000:5
4000:5
5000:5
6000:5
Relay
Class
C20
C20
C20
C50
C50
C100
C100
C100
C100
C100
C100
C100
C100
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
For Ground Fault Sensing
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Metering Class
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
— — 1.33
2.4
1.2
1.2
1.2
1.2
0.6
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Toroidal Current Transformers (152R, 170R, 180R, 210R)
Table 6.18: Toroidal Current Transformers, UR/cUR Recognized, 25–400 Hz
Window
Size
(inches)
6-7/8
4-1/4
2-1/2
2-1/2
Catalog
Number
(without
brackets) [4]
152R500
152R101
152R151
152R201
152R251
152R301
152R401
152R501
152R601
152R801
152R102
152R122
152R152
152R162
152R202
152R252
152R302
152R402
170R201
170R251
170R301
170R401
170R501
170R601
170R751
170R801
170R102
170R122
170R152
170R162
170R202
170R252
180R101
180R151
180R201
180R251
180R301
180R401
180R501
180R601
180R751
180R801
180R102
180R122
180R152
210R122
210R162
210R202
210R252
210R302
210R402
Current
Rating
(Amperes)
50:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
3000:5
4000:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
1200:5
1600:5
2000:5
2500:5
3000:5
4000:5
Relay
Class
C10
C20
C50
C50
C50
C100
C100
C100
C200
C200
C200
C400
C400
C400
C400
C400
C400
C800
—
—
—
—
—
—
C10
C10
C10
C10
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
C100
C100
C100
C200
C200
C200
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Metering Class
—
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.6
0.6
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
0.6
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
—
—
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
0.6
0.6
0.3
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
—
—
—
—
—
2.4
2.4
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
—
—
—
—
—
—
—
2.4
1.2
1.2
0.6
0.6
0.6
0.6
0.3
0.3
—
—
—
—
—
—
—
—
2.4
1.2
1.2
0.6
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
—
—
—
Rating
Factor
o
C
30
Ambient
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.00
1.00
Rating
Factor
o
30
C
Ambient
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.0
1.0
TRANSFORMERS
6
[4] For mounting brackets, refer to Bushing Current Transformers 50–400 Hz, page 6-14
© 2019 Schneider Electric
All Rights Reserved
6-11
Instrument 600 Volt Class Current Transformers: Multi-Ratio,
8.50
8.50
3 .2 5
X1
4.62
HI
A
C
L
C
L
1.0 1.0
X5 X4 X3 X2 X1
HI
C
L
C
L
A
C
B
B
Rectangular, Split-Core
Class 4210 / Refer to Catalog 4210CT9701
Toroidal Current Transformers (200R, 201R, 202R, 203R)
Models 200R, 201R, 202R, 203R
Table 6.19: Dimensions for Models 200R, 201R,
202R, and 203R
Model [5] Dimensions A (inches)
200R
201R
202R
203R
2.50
3.50
4.50
5.25
Table 6.20: Toroidal Current Transformers, UR/cUR Recognized, 25–400 Hz
Window
Size
(inches)
2-1/2
3-1/2
4-1/2
5-1/4
Catalog
Number
(without
brackets) [6]
200R101
200R151
200R201
200R251
200R301
200R401
200R501
200R601
201R101
201R151
201R201
201R251
201R301
201R401
201R501
201R601
201R751
201R801
202R101
202R151
202R201
202R251
202R301
202R401
202R501
202R601
202R751
202R801
202R102
203R101
203R151
203R201
203R251
203R301
203R401
203R501
203R601
203R751
203R801
203R102
203R122
203R152
203R162
203R202
203R252
203R302
Current
Rating
(Amperes)
100:5
150:0
200:5
250:5
300:5
400:5
500:5
600:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
100:5
150:5
200:5
250:5
300:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
3000:5
Relay
Class
C50
C50
C100
C100
C100
C200
C200
C200
C20
C50
C50
C100
C100
C100
C200
C200
C200
C200
C20
C20
C50
C50
C50
C100
C100
C100
C200
C200
C200
C20
C20
C20
C20
C50
C50
C100
C100
C100
C100
C200
C200
C200
C200
C200
C200
C200
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Metering Class
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
2.4
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
schneider-electric.us
Rating
Factor
o
30
C
2.4
1.2
1.2
0.6
0.3
0.3
0.3
2.4
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
2.4
1.2
1.2
0.6
0.8
0.3
0.3
0.3
0.3
2.4
2.4
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Ambient
1.5
—
1.5
1.5
1.5
1.5
1.5
1.5
1.5
—
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
—
1.5
—
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
—
1.5
—
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.33
1.33
1.33
1.33
—
1.2
1.2
0.6
0.3
0.3
0.3
0.3
2.4
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
—
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
—
—
2.4
2.4
1.2
1.2
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
6
TRANSFORMERS
Shorting Terminal Blocks
Table 6.21: Shorting Terminal Blocks
Multi-Ratio Current Transformers
Table 6.23: Multi-Ratio Transformers, UR/cUR Recognized 60 Hz-Model 312R, 25–
400 Hz-Model 151R
Window
Size
(inches)
4-1⁄2
6-7⁄8
Models 151R, 312R
Table 6.22: Dimensions for Models 151R and 312R
Model
151R
312R
[5] Base is included.
[6] For mounting brackets, refer to Bushing Current Transformers 50–400 Hz, page 6-14
[7] For multi-ratio (MR) taps, refer to the Multi-Ratio Taps table.
[8] Relay class applies to nominal ratio only.
[9] Taps in acordance with ANSI C57.13 and NEMA SG-4.
6-12
Dimensions (inches)
A B C
6.88
4.50
12.25
11.00
4.12
2.38
Table 6.24: Multi-Ratio Taps (Models 151R, 312R, 781R, 786R)
Nominal Ratio
Catalog No. Description
3090TB4
3090TB6
Catalog
Number
(without
brackets) [6]
312R601
312R122
312R202
312R302
312R402
151R601
151R122
151R202
151R302
151R402
600:5 600/500/450/400/300/250/200/150/100/50:5
1200:5 1200/1000/900/800/600/500/400/300/200/100:5
2000:5 2000/1600/1500/1200/1100/800/500/400/300:5
3000:5 3000/2500/2200/2000/1500/1200/1000/800/500/300:5
4000:5 4000/3500/3000/2500/2000/1500/1000/500
Shorting terminal block (4-pole)
Shorting terminal block (6-pole)
Current
Rating [7]
(Amperes)
600:5MR
1200:5MR
2000:5MR
3000:5MR
4000:5MR
600:5MR
1200:5MR
2000:5MR
3000:5MR
4000:5MR
Relay
Class
[8]
C100
C200
C400
C400
C400
C200
C400
C400
C400
C800
Current Ratio [9] (Amperes)
ANSI Accuracy Classification – 60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
—
—
—
—
—
—
—
—
—
—
Metering Class
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Rating
Factor
30
—
—
—
—
—
—
—
—
—
—
© 2019 Schneider Electric
Ambient
—
—
—
—
—
1.33
—
—
—
—
—
All Rights Reserved
1.5
1.5
1.5
1.5
1.33
1.33
1.33
1.33
1.33
o
C
Current Transformers: Multi-Ratio,
Rectangular, Split-Core
schneider-electric.us
Table 6.25: Dimensions for Models 260R, and 560R
Model
260R
560R
A B C D E
2.13
3.75
Table 6.27: Dimensions for Models 270R, and 273
Model
270R
273
A B C D E
3.56
3.50
Class 4210 / Refer to Catalog 4210CT9701
260R, 560R
Dimensions (inches)
4.25
7.45
Models 270R, and 273
8.81
6.25
2.12
1.13
Dimensions (inches)
3.00
3.27
4.88
5.53
9.25
9.25
7.25
11.19
13.06
11.28
Instrument 600 Volt Class
Rectangular Window Current Transformers
Table 6.26: Rectangular Window Transformers, UR/cUR Recognized, 50–400 Hz
Window
Size
(inches)
2-1/8
4-1/4
3-3/4
7-7/16
Catalog
Number
(without
brackets)
[10]
260R101
260R151
260R201
260R301
260R401
260R601
x
260R801
260R122
260R162
260R202
260R252
260R302
260R402
560R401
560R501
560R601
560R751
560R801
560R102
560R122
x
560R152
560R162
560R202
560R252
560R302
560R322
560R402
560R502
Current
Rating
(Amperes)
100:5
150:5
200:5
300:5
400:5
600:5
800:5
1200:5
1600:5
2000:5
2500:5
3000:5
4000:5
400:5
500:5
600:5
750:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
3000:5
3200:5
4000:5
5000:5
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
1.2
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
0.6
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Metering Class
2.4
2.4
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.2
1.2
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
2.4
2.4
1.2
1.2
1.2
0.6
0.6
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2.4
1.2
1.2
1.2
0.6
0.6
0.6
0.6
0.3
0.3
0.3
0.3
0.3
2.4
2.4
2.4
1.2
1.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Rating
Factor
30
Ambient
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.0
1.0
1.0
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
Split-Core Current Transformers
Table 6.28: Split-Core Transformers, Model 270R is UR/cUR Recognized, 60 Hz
Window
Size
(inches)
3-9/16
8-3/16
3-9/16
8-3/16
3-1/2
6-1/4
Catalog
Number
(without
brackets)
[10]
270R401
x
270R501
270R601
270R801
270R102
270R122
270R152
270R162
x
270R202
270R252
270R302
270R402
270R502
273201
273251
273301
273401
273501
273601
273801
x
273102
273122
273162
273202
273252
273302
273402
Current
Rating
(Amperes)
400:5
500:5
600:5
800:5
1000:5
1200:5
1500:5
1600:5
2000:5
2500:5
3000:5
4000:5
5000:5
200:5
250:5
300:5
400:5
500:5
600:5
800:5
1000:5
1200:5
1600:5
2000:5
2500:5
3000:5
4000:5
ANSI Accuracy Classification — 60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
—
—
—
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
—
—
2.4
2.4
2.4
2.4
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
Metering Class
—
—
—
2.4
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
—
—
—
—
—
2.4
2.4
1.2
1.2
1.2
1.2
1.2
1.2
1.2
2.4
2.4
2.4
2.4
1.2
1.2
1.2
1.2
1.2
2.4
2.4
2.4
1.2
1.2
1.2
1.2
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2.4
2.4
1.2
1.2
1.2
—
—
—
—
—
—
—
—
—
—
2.4
2.4
1.2
1.2
2.4
1.2
1.2
2.4
1.2
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Rating
Factor
30
Ambient
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.0
1.0
1.0
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.33
1.00
1.00
o
C
o
C
[10] For mounting brackets, refer to Bushing Current Transformers 50–400 Hz, page 6-14
© 2019 Schneider Electric
All Rights Reserved
TRANSFORMERS
6
6-13
Instrument 600 Volt Class Current Transformers: Bushing, Auxiliary
H2 H1
9.88
251
9.88
251
6.5
T
5.88
149
3.25
83
6.38
162
.75
19
10-32 Studs
Class 4210 / Refer to Catalog 4210CT9701
Bushing Current Transformers 50–400 Hz
Models 780 R, 781R, 785R, and 786R
Table 6.29: Dimensions for Models 780R, 781R,
785R, and 786R
Model
780R
781R
785R
786R
T (inches)
Table 6.30: Mounting Brackets
2NR MB1
5NR MB1
7RL MB7
54R Included
64R MB10
66R MB12
74R MB16
76R MB18
81X MB81
100R MB31
110R MB32
120R MB31
140R MB32
151R MB30
152R MB30
170R MB30
180R MB9
200R Included
201R Included
202R Included
203R Included
210R MB32
260R Not Available
270R Not Available
273 Not Available
Model Bracket
6
TRANSFORMERS
3.38
3.38
6.75
6.75
Table 6.31: Bushing Current Transformers
Window
Size
(inches)
6-1⁄2
6-1⁄2
6-1⁄2
6-1⁄2
Catalog
Number
780R500 50:5 — — — — — — 2.0
780R750 75:5 C10 1.2 2.4 — — — 2.0
780R101 100:5 C10 2.4 2.4 — — — 2.0
780R151 150:5 C20 0.6 1.2 — — — 2.0
780R201 200:5 C20 0.6 1.2 2.4 — — 2.0
780R251 250:5 C20 0.6 0.6 1.2 2.4 — 2.0
780R301 300:5 C50 0.3 0.6 1.2 1.2 2.4 2.0
780R401 400:5 C50 0.3 0.3 0.6 1.2 1.2 2.0
780R501 500:5 C50 0.3 0.3 0.6 0.6 1.2 2.0
780R601 600:5 C100 0.3 0.3 0.3 0.6 0.6 2.0
780R751 750:5 C100 0.3 0.3 0.3 0.3 0.6 2.0
780R801 800:5 C100 0.3 0.3 0.3 0.3 0.6 2.0
780R102 1000:5 C100 0.3 0.3 0.3 0.3 0.3 2.0
780R122 1200:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
780R152 1500:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
780R162 1600:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
780R202 2000:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
780R252 2500:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
780R302 3000:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
780R402 4000:5 C200 0.3 0.3 0.3 0.3 0.3 1.5
781R601 600:5 MR C100 0.3 0.3 0.3 0.6 0.6 2.0
781R122 1200:5 MR C200 0.3 0.3 0.3 0.3 0.3 2.0
781R202 2000:5 MR C200 0.3 0.3 0.3 0.3 0.3 2.0
781R302 3000:5 MR C200 0.3 0.3 0.3 0.3 0.3 2.0
781R402 4000:5 MR C200 0.3 0.3 0.3 0.3 0.3 1.5
785R500 50:5 C10 2.4 2.4 — — — 2.0
785R750 75:5 C20 1.2 1.2 — — — 2.0
785R101 100:5 C20 1.2 1.2 2.4 — — 2.0
785R151 150:5 C50 0.6 0.6 1.2 2.4
785R201 200:5 C50 0.6 0.6 1.2 2.4 2.4 2.0
785R251 250:5 C50 0.3 0.6 1.2 1.2 2.4 2.0
785R301 300:5 C100 0.3 0.3 0.6 0.6 1.2 2.0
785R401 400:5 C100 0.3 0.3 0.3 0.6 1.2 2.0
785R501 500:5 C100 0.3 0.3 0.3 0.6 0.6 2.0
785R601 600:5 C200 0.3 0.3 0.3 0.3 0.6 2.0
785R751 750:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
785R801 800:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
785R102 1000:5 C200 0.3 0.3 0.3 0.3 0.3 2.0
785R122 1200:5 C400 0.3 0.3 0.3 0.3 0.3 2.0
785R152 1500:5 C400 0.3 0.3 0.3 0.3 0.3 2.0
785R162 1600:5 C400 0.3 0.3 0.3 0.3 0.3 2.0
785R202 2000:5 C400 0.3 0.3 0.3 0.3 0.3 2.0
785R252 2500:5 C400 0.3 0.3 0.3 0.3 0.3 2.0
785R302 3000:5 C400 0.3 0.3 0.3 0.3 0.3 2.0
785R402 4000:5 C400 0.3 0.3 0.3 0.3 0.3 1.5
786R601 600:5 MR C200 0.3 0.3 0.3 0.3 0.3 2.0
786R122 1200:5 MR C400 0.3 0.3 0.3 0.3 0.3 2.0
786R202 2000:5 MR C400 0.3 0.3 0.3 0.3 0.3 2.0
786R302 3000:5 MR C400 0.3 0.3 0.3 0.3 0.3 2.0
786R402 4000:5 MR C400 0.3 0.3 0.3 0.3 0.3 1.5
Current
Rating [11]
(Amperes)
Relay
Class
Auxiliary Current Transformers
Table 6.32: Auxiliary Current Transformers
NOTE: Model 81X Accuracy 0.3B0.1, B0.2, B0.5@60 Hz, RF=1.5@30 oC
Catalog Number
(without brackets)
81X05000100
81X05000200
81X05000250
81X05000500
81X07500500
81X10000500
81X12500500
81X15000500
ANSI Accuracy Classification—60 Hz
B-0.1 B-0.2 B-0.5 B-0.9 B-1.8
Metering Class
schneider-electric.us
Rating
Factor
30
Ambient
_
2.0
Ratio
5:1
5:2
5:2.5
5:5
7.5:5
10:5
12.5:5
15:5
o
C
Model 81X
[11] For multi-ratio (MR) taps, refer to Table 6.24 Multi-Ratio Taps (Models 151R, 312R, 781R, 786R), page 6-12
6-14
© 2019 Schneider Electric
All Rights Reserved
Transformers—Obsolete Instrument 600 Volt Class
Class 7400 / Refer to Catalog 7400CT0601
schneider-electric.us
Obsolete—January 1, 2016
Energy Efficient Three-Phase
NOTE: International products—for export use only.
Table 6.33: EE Three Phase; 60HZ; 208Y/120 Secondary; cULus Listed
kVA
480 V Delta Primary, Aluminum Windings
15 EE15T3H 97.0% 6–2.5%2+4– 150 220 5.1% 45 220 17D
30 EE30T3H 97.5% 6–2.5%2+4– 150 220 5.5% 45 260 17D
45 EE45T3H 97.7% 6–2.5%2+4– 150 220 6.0% 45 368 18D
75 EE75T3H 98.0% 6–2.5%2+4– 150 220 3.7% 50 585 20D
112.5 EE112T3H 98.2% 6–2.5%2+4– 150 220 5.2% 50 620 21D
150 EE150T3H 98.3% 6–2.5%2+4– 150 220 6.0% 50 835 22D
225 EE225T3H 98.5% 6–2.5%2+4– 150 220 6.5% 55 1110 24D
300 EE300T3H 98.6% 6–2.5%2+4– 150 220 5.9% 55 1350 25D
500 EE500T68H 98.7% 4–2.5%2+2– 150 220 6.1% 60 1875 30D
750 EE750T68H 98.8% 4–2.5%2+2– 150 220 5.4% 64 2965 31D
1000 EE1000T77H 98.9% 2–5%1+1– 150 220 5.7% 64 5200 33F
600 V Delta Primary, Aluminum Windings
15 EE15T65H 97.0% 6–2.5%2+4– 150 220 4.5% 45 240 17D
30 EE30T65H 97.5% 6–2.5%2+4– 150 220 5.9% 45 290 17D
45 EE45T65H 97.7% 6–2.5%2+4– 150 220 6.4% 45 372 18D
75 EE75T65H 98.0% 6–2.5%2+4– 150 220 3.6% 50 585 20D
112.5 EE112T65H 98.2% 6–2.5%2+4– 150 220 5.0% 50 712 21D
150 EE150T65H 98.3% 6–2.5%2+4– 150 220 3.7% 50 790 22D
225 EE225T65H 98.5% 6–2.5%2+4– 150 220 5.1% 55 945 24D
300 EE300T65H 98.6% 6–2.5%2+4– 150 220 5.6% 55 1305 25D
500 EE500T79H 98.7% 4–2.5%2+2– 150 220 6.0% 60 1870 30D
750 EE750T79H 98.8% 4–2.5%2+2– 150 220 5.4% 64 2990 31D
1000 EE1000T79H 98.9% 4–2.5%2+2– 150 220 — 64 5800 33F
208 V Delta Primary, Aluminum Windings
15 EE15T211H 97.0% 3–5%1+2– 150 220 5.1% 45 210 17D
30 EE30T211H 97.5% 3–5%1+2– 150 220 6.1% 45 210 17D
45 EE45T211H 97.7% 3–5%1+2– 150 220 5.7% 45 374 18D
75 EE75T211H 98.0% 3–5%1+2– 150 220 3.8% 50 575 20D
112.5 EE112T211H 98.2% 3–5%1+2– 150 220 5.3% 50 604 21D
150 EE150T211H 98.3% 3–5%1+2– 150 220 3.6% 50 795 22D
225 EE225T211H 98.5% 3–5%1+2– 150 220 4.9% 55 1000 24D
300 EE300T211H 98.6% 3–5%1+2– 150 220 5.2% 55 1425 25D
500 EE500T211H 98.7% 3–5%1+2– 150 220 6.2% 60 1870 30D
240 V Delta Primary, Aluminum Windings
15 EE15T67H 97.0% 6–2.5%2+4– 150 220 4.1% 45 240 17D
30 EE30T67H 97.5% 6–2.5%2+4– 150 220 6.2% 45 260 17D
45 EE45T67H 97.7% 6–2.5%2+4– 150 220 5.7% 45 379 18D
75 EE75T67H 98.0% 6–2.5%2+4– 150 220 4.2% 50 590 20D
112.5 EE112T67H 98.2% 6–2.5%2+4– 150 220 6.0% 50 620 21D
150 EE150T67H 98.3% 6–2.5%2+4– 150 220 3.3% 50 805 22D
225 EE225T67H 98.5% 6–2.5%2+4– 150 220 5.2% 55 972 24D
300 EE300T239H 98.6% 3–5%1+2– 150 220 5.4% 55 1360 25D
500 EE500T239H 98.7% 3–5%1+2– 150 220 6.3% 60 1900 25D
480 V Delta Primary, Copper Windings
15 EE15T3HCU 97.0% 6–2.5%2+4– 150 220 4.6% 45 310 17D
30 EE30T3HCU 97.5% 6–2.5%2+4– 150 220 4.6% 45 340 17D
45 EE45T3HCU 97.7% 6–2.5%2+4– 150 220 4.4% 45 418 18D
75 EE75T3HCU 98.0% 6–2.5%2+4– 150 220 3.5% 50 642 20D
112.5 EE112T3HCU 98.2% 6–2.5%2+4– 150 220 3.9% 50 725 21D
150 EE150T3HCU 98.3% 6–2.5%2+4– 150 220 4.7% 50 915 22D
225 EE225T3HCU 98.5% 6–2.5%2+4– 150 220 3.8% 55 1125 24D
300 EE300T3HCU 98.6% 6–2.5%2+4– 150 220 4.8% 55 1535 25D
500 EE500T68HCU 98.7% 4–2.5%2+2– 150 220 4.1% 60 2350 30D
750 EE750T68HCU 98.8% 4–2.5%2+2– 150 220 4.7% — 3485 31D
Catalog No.
Table 6.34: EE Three Phase; 60HZ; 480Y/277 Secondary; cULus Listed
Catalog No.
kVA
208 V Delta Primary, Aluminum Windings
15 EE15T212H 97.0% 3–5%1+2– 150 220 4.2% 45 220 17D 27.00 / 686 20.00 / 508 16.00 / 406
30 EE30T212H 97.5% 3–5%1+2– 150 220 6.5% 45 260 17D 27.00 / 686 20.00 / 508 16.00 / 406
45 EE45T212H 97.7% 3–5%1+2– 150 220 6.0% 45 368 18D 30.00 / 762 20.00 / 508 20.00 / 508
75 EE75T212H 98.0% 3–5%1+2– 150 220 6.9% 50 585 20D 37.00 / 940 30.00 / 762 20.00 / 508
112.5 EE112T212H 98.2% 3–5%1+2– 150 220 5.4% 50 620 21D 37.00 / 940 30.00 / 762 24.00 / 610
150 EE150T212H 98.3% 3–5%1+2– 150 220 6.4% 50 835 22D 43.75 / 1111 32.00 / 813 27.00 / 686
225 EE225T212H 98.5% 3–5%1+2– 150 220 4.7% 55 1110 24D 49.5 / 1257 35 / 889 28.5 / 724
300 EE300T212H 98.6% 3–5%1+2– 150 220 5.1% 55 1350 25D 49.5 / 1257 41 / 1041 32 / 813
500 EE500T212H 98.7% 3–5%1+2– 150 220 6.5% 60 1875 30D 71 / 1803 48 / 1219 36 / 914
480 V Delta Primary, Aluminum Windings
15 EE15T1814H 97.0% 6–2.5%2+4– 150 220 4.8% 45 240 17D 27.00 / 686 20.00 / 508 16.00 / 406
30 EE30T1814H 97.5% 6–2.5%2+4– 150 220 4.7% 45 290 17D 27.00 / 686 20.00 / 508 16.00 / 406
45 EE45T1814H 97.7% 6–2.5%2+4– 150 220 5.7% 45 372 18D 30.00 / 762 20.00 / 508 20.00 / 508
75 EE75T1814H 98.0% 6–2.5%2+4– 150 220 4.5% 50 585 20D 37.00 / 940 30.00 / 762 20.00 / 508
112.5 EE112T1814H 98.2% 6–2.5%2+4– 150 220 5.1% 50 712 21D 37.00 / 940 30.00 / 762 24.00 / 610
150 EE150T1814H 98.3% 6–2.5%2+4– 150 220 3.3% 50 790 22D 43.75 / 1111 32.00 / 813 27.00 / 686
225 EE225T1814H 98.5% 6–2.5%2+4– 150 220 4.0% 55 945 24D 49.5 / 1257 35 / 889 28.5 / 724
300 EE300T1814H 98.6% 6–2.5%2+4– 150 220 4.9% 55 1305 25D 49.5 / 1257 41 / 1041 32 / 813
500 EE500T76H 98.7% 4–2.5%2+2– 150 220 5.8% 60 1870 30D 71 / 1803 48 / 1219 36 / 914
Minimum
Efficiency @
35% 75° C
Minimum
Efficiency @ 35%
75° C
Full
Capacity
Taps
Full Capacity
Taps
Degree C
Temp. Rise
Degree C Temp.
Insulation
Class
Rise
Insulation Class %IZ Sound Level dB
%IZ
Sound
Level dB
Weight
(lbs)
Weight (lbs)
Enclosure H W D
Enclosure
TRANSFORMERS
6
© 2019 Schneider Electric
All Rights Reserved
6-15
Instrument 600 Volt Class Transformers—Obsolete
Class 7400 / Refer to Catalog 7400CT0601
Obsolete—January 1, 2016
Table 6.35: EE Three Phase; 60HZ; 240 Delta Secondary; cULus Listed
kVA
480 V Delta Primary, Aluminum Windings
15 EE15T6H 97.0% 6–2.5%2+4– 150 220 4.1% 45 220 17D
30 EE30T6H 97.5% 6–2.5%2+4– 150 220 5.6% 45 260 17D
45 EE45T6H 97.7% 6–2.5%2+4– 150 220 6.1% 45 368 18D
75 EE75T6H 98.0% 6–2.5%2+4– 150 220 3.9% 50 585 20D
112.5 EE112T6H 98.2% 6–2.5%2+4– 150 220 5.4% 50 620 21D
150 EE150T6H 98.3% 6–2.5%2+4– 150 220 3.9% 50 835 22D
225 EE225T6H 98.5% 6–2.5%2+4– 150 220 4.4% 55 1110 24D
300 EE300T6H 98.6% 6–2.5%2+4– 150 220 5.3% 55 1350 25D
500 EE500T63H 98.7% 4–2.5%2+2– 150 220 5.7% 60 1875 30D
750 EE750T63H 98.8% 4–2.5%2+2– 150 220 5.2% 64 2965 31D
1000 EE1000T78H 98.9% 2–5%1+1– 150 220 5.3% 64 5200 33F
480 V Delta Primary, Aluminum Windings
240 Delta with 120 center taps have historically been limited to 5% capacity on the center tap. The new units from Schneider Electricoffer greater limits on 120 V center tap. Limits are
determined by the totaltransformer loading and the following formula used to size new 120 V center tap units:(240 V balanced loads) + 2.5 x (120 V loads)= kVA required
15 EE15T151HCT 97.0% 2–5%– 150 220 5.3% 45 220 17D
30 EE30T151HCT 97.5% 2–5%– 150 220 5.6% 45 295 17D
45 EE45T151HCT 97.7% 2–5%– 150 220 5.7% 45 385 18D
75 EE75T151HCT 98.0% 2–5%– 150 220 4.7% 50 590 19D
112.5 EE112T151HCT 98.2% 2–5%– 150 220 4.3% 50 635 21D
150 EE150T151HCT 98.3% 2–5%– 150 220 3.1% 50 783 22D
225 EE225T151HCT 98.5% 2–5%– 150 220 3.8% 55 1080 24D
300 EE300T151HCT 98.6% 2–5%– 150 220 4.6% 55 1355 25D
500 EE500T151HCT 98.7% 2–5%– 150 220 5.1% 60 2137 30D
750 EE750T151HCT 98.8% 2–5%– 150 220 5.6% 64 2982 31D
1000 EE1000T151HCT 98.9% 2–5%– 150 220 — 64 5800 33F
Catalog No.
Minimum
Efficiency @ 35%
75° C
Full Capacity
Taps
Degree C
Temp. Rise
Insulation Class %IZ Sound Level dB
Weight (lbs)
Obsolete—January 1, 2016
EE Watchdog Transformers
NOTE: International products—for export use only.
Table 6.36: EE Three Phase Watchdog Transformers: 60HZ, cULus Listed
kVA
480 V Delta Primary, 208Y/120 Secondary, Aluminum Windings
15 EE15T3HF 97.0% 6–2.5%2+4– 115 220 5.3% 45 220 17D
30 EE30T3HF 97.5% 6–2.5%2+4– 115 220 5.3% 45 368 18D
45 EE45T3HF 97.7% 6–2.5%2+4– 115 220 5.2% 45 585 20D
75 EE75T3HF 98.0% 6–2.5%2+4– 115 220 6.3% 50 620 21D
112.5 EE112T3HF 98.2% 6–2.5%2+4– 115 220 5.3% 50 835 22D
150 EE150T3HF 98.3% 6–2.5%2+4– 115 220 5.1% 50 980 24D
225 EE225T3HF 98.5% 6–2.5%2+4– 115 220 6.0% 55 1349 25D
300 EE300T68HF 98.6% 4–2.5%2+2– 115 220 3.7% 55 2050 30D
500 EE500T68HF 98.7% 4–2.5%2+2– 115 220 6.6% 60 2330 30D
480 V Delta Primary, 208Y/120 Secondary, Copper Windings
15 EE15T3HFCU 97.0% 6–2.5%2+4– 115 220 5.0% 45 260 17D
30 EE30T3HFCU 97.5% 6–2.5%2+4– 115 220 2.8% 45 420 18D
45 EE45T3HFCU 97.7% 6–2.5%2+4– 115 220 2.0% 45 642 20D
75 EE75T3HFCU 98.0% 6–2.5%2+4– 115 220 3.4% 50 675 21D
112.5 EE112T3HFCU 98.2% 6–2.5%2+4– 115 220 3.7% 50 471 22D
6
150 EE150T3HFCU 98.3% 6–2.5%2+4– 115 220 2.5% 50 1050 24D
225 EE225T3HFCU 98.5% 6–2.5%2+4– 115 220 3.8% 55 1220 25D
300 EE300T68HFCU 98.6% 4–2.5%2+2– 115 220 4.8% 55 2300 30D
500 EE500T68HFCU 98.7% 4–2.5%2+2– 115 220 4.1% 60 2409 30D
480 V Delta Primary, 208Y/120 Secondary, Aluminum Windings
15 EE15T3HB 97.0% 6–2.5%2+4– 80 220 5.1% 45 220 17D
30 EE30T3HB 97.5% 6–2.5%2+4– 80 220 3.7% 45 368 18D
45 EE45T3HB 97.7% 6–2.5%2+4– 80 220 2.1% 45 585 20D
75 EE75T3HB 98.0% 6–2.5%2+4– 80 220 3.3% 50 620 21D
TRANSFORMERS
112.5 EE112T3HB 98.2% 6–2.5%2+4– 80 220 3.7% 50 835 22D
150 EE150T3HB 98.3% 6–2.5%2+4– 80 220 3.1% 50 980 24D
225 EE225T3HB 98.5% 6–2.5%2+4– 80 220 4.2% 55 1349 25D
300 EE300T68HB 98.6% 4–2.5%2+2– 80 220 4.8% 55 2400 30D
500 EE500T68HB 98.7% 4–2.5%2+2– 80 220 3.6% 60 2964 30D
480 V Delta Primary, 208Y/120 Secondary, Copper Windings
15 EE15T3HBCU 97.0% 6–2.5%2+4– 80 220 4.7% 45 260 17D
30 EE30T3HBCU 97.5% 6–2.5%2+4– 80 220 2.7% 45 418 18D
45 EE45T3HBCU 97.7% 6–2.5%2+4– 80 220 1.8% 45 642 20D
75 EE75T3HBCU 98.0% 6–2.5%2+4– 80 220 2.5% 50 725 21D
112.5 EE112T3HBCU 98.2% 6–2.5%2+4– 80 220 2.2% 50 910 22D
150 EE150T3HBCU 98.3% 6–2.5%2+4– 80 220 2.3% 50 1125 24D
225 EE225T3HBCU 98.5% 6–2.5%2+4– 80 220 3.6% 55 1425 25D
300 EE300T68HBCU 98.6% 4–2.5%2+2– 80 220 4.3% 55 2400 30D
500 EE500T68HBCU 98.7% 4–2.5%2+2– 80 220 5.0% 60 2578 30D
Catalog No.
Minimum
Efficiency @ 35%
75° C
Full Capacity
Taps
Degree C
Temp. Rise
Insulation
Class
%IZ Sound Level dB
Weight (lbs)
schneider-electric.us
Enclosure
Enclosure
6-16
© 2019 Schneider Electric
All Rights Reserved
Transformers—Obsolete Instrument 600 Volt Class
Class 7400 / Refer to Catalog 7400CT0601
schneider-electric.us
Obsolete—January 1, 2016
EE NL and NLP Series Transformers
International products—for export use only.
•
Three-phase dry type transformers, 480 Delta to 208Y/120
•
Aluminum or copper windings
•
Electrostatic shield
•
Class 220 insulation
•
Double size neutral terminal for additional customer neutral cables
•
Additional coil capacity to compensate for higher non-linear load loss
•
cULus Listed
•
Table 6.37: EE Three Phase; 60HZ; 480 V Delta Primary, 208Y/120 Secondary; cULus Listed
kVA
NL Series for Typical Non-Linear Load Services, K-4 Rated, Aluminum Windings
15 EE15T3HFISNL 97.0% 6–2.5%2+4– 115 220 4.0% 45 256 17D
30 EE30T3HFISNL 97.5% 6–2.5%2+4– 115 220 4.6% 45 320 18D
45 EE45T3HFISNL 97.7% 6–2.5%2+4– 115 220 3.3% 45 515 20D
75 EE75T3HFISNL 98.0% 6–2.5%2+4– 115 220 4.4% 50 535 21D
112.5 EE112T3HFISNL 98.2% 6–2.5%2+4– 115 220 5.2% 50 800 22D
150 EE150T3HFISNL 98.3% 6–2.5%2+4– 115 220 3.4% 50 1110 24D
225 EE225T3HFISNL 98.5% 6–2.5%2+4– 115 220 4.4% 55 1349 25D
300 EE300T68HFISNL 98.6% 6–2.5%2+4– 115 220 4.8% 55 1750 30D
500 EE500T68HFISNL 98.7% 4–2.5%2+2– 115 220 4.2% 60 2295 31D
NL Series for Typical Non-Linear Load Services, K-4 Rated, Copper Windings
15 EE15T3HFISCUNL 97.0% 6–2.5%2+4– 115 220 4.7% 45 260 17D
30 EE30T3HFISCUNL 97.5% 6–2.5%2+4– 115 220 3.4% 45 395 18D
45 EE45T3HFISCUNL 97.7% 6–2.5%2+4– 115 220 5.2% 45 730 20D
75 EE75T3HFISCUNL 98.0% 6–2.5%2+4– 115 220 6.5% 50 640 20D
112.5 EE112T3HFISCUNL 98.2% 6–2.5%2+4– 115 220 3.8% 50 935 22D
150 EE150T3HFISCUNL 98.3% 6–2.5%2+4– 115 220 4.6% 50 1300 24D
225 EE225T3HFISCUNL 98.5% 6–2.5%2+4– 115 220 3.6% 55 1450 24D
300 EE300T68HFISCUNL 98.6% 6–2.5%2+4– 115 220 4.7% 55 2450 25D
500 EE500T68HFISCUNL 98.7% 4–2.5%2+2– 115 220 5.0% 60 31D
NLP Series for Typical Non-Linear Load Services, K-13 Rated, Aluminum Windings
15 EE15T3HFISNLP 97.0% 6–2.5%2+4– 115 220 4.0% 45 256 17D
30 EE30T3HFISNLP 97.5% 6–2.5%2+4– 115 220 4.6% 45 375 18D
45 EE45T3HFISNLP 97.7% 6–2.5%2+4– 115 220 3.3% 45 500 20D
75 EE75T3HFISNLP 98.0% 6–2.5%2+4– 115 220 3.3% 50 560 21D
112.5 EE112T3HFISNLP 98.2% 6–2.5%2+4– 115 220 4.7% 50 800 22D
150 EE150T3HFISNLP 98.3% 6–2.5%2+4– 115 220 3.4% 50 1110 24D
225 EE225T3HFISNLP 98.5% 6–2.5%2+4– 115 220 4.4% 55 1335 25D
300 EE300T68HFISNLP 98.6% 6–2.5%2+4– 115 220 4.4% 55 2350 30D
500 EE500T68HFISNLP 98.7% 4–2.5%2+2– 115 220 5.0% 60 3200 31D
NLP Series for Typical Non-Linear Load Services, K-13 Rated, Copper Windings
15 EE15T3HFISCUNLP 97.0% 6–2.5%2+4– 115 220 3.8% 45 260 17D
30 EE30T3HFISCUNLP 97.5% 6–2.5%2+4– 115 220 3.4% 45 430 18D
45 EE45T3HFISCUNLP 97.7% 6–2.5%2+4– 115 220 4.5% 45 730 20D
75 EE75T3HFISCUNLP 98.0% 6–2.5%2+4– 115 220 6.5% 50 640 20D
112.5 EE112T3HFISCUNLP 98.2% 6–2.5%2+4– 115 220 3.7% 50 985 22D
150 EE150T3HFISCUNLP 98.3% 6–2.5%2+4– 115 220 4.4% 50 1135 24D
225 EE225T3HFISCUNLP 98.5% 6–2.5%2+4– 115 220 3.6% 55 1477 24D
300 EE300T68HFISCUNLP 98.6% 6–2.5%2+4– 115 220 3.5% 55 2650 30D
500 EE500T68HFISCUNLP 98.7% 4–2.5%2+2– 115 220 5.5% 60 — 31D
Catalog No.
Minimum
Efficiency @ 35%
75° C
Full Capacity
Taps
Degree C
Temp. Rise
Insulation Class %IZ
Sound Level
dB
Weight (lbs)
Enclosure
© 2019 Schneider Electric
All Rights Reserved
TRANSFORMERS
6
6-17
Instrument 600 Volt Class Transformers—Obsolete
Class 7400 / Refer to Catalog 7400CT0601
schneider-electric.us
Obsolete—January 1, 2016
NOTE: International products—for export use only.
Table 6.38: Harmonic Mitigating, 480 Primary to 208zz/120 Secondary—UL Listed
kVA
480 V Delta Primary to 208/120 V Secondary with a 0° Phase Shift, 130° Rise
15 HM15T208NCU 97.0% 6–2.5% 2+4– 130 200 4.5% 45 310 17D
30 HM30T208NCU 97.5% 6–2.5% 2+4– 130 200 4.5% 45 340 17D
45 HM45T208NCU 97.7% 6–2.5% 2+4– 130 200 6.8% 45 418 18D
75 HM75T208NCU 98.0% 6–2.5% 2+4– 130 200 4.0% 50 642 20D
112.5 HM112T208NCU 98.2% 6–2.5% 2+4– 130 200 4.4% 50 725 21D
150 HM150T208NCU 98.3% 6–2.5% 2+4– 130 200 3.1% 50 915 22D
225 HM225T208NCU 98.5% 6–2.5% 2+4– 130 200 6.4% 55 1125 24D
300 HM300T208NCU 98.6% 4–2.5% 2+2– 130 200 5.6% 55 1535 25D
480 V Primary to 208/120 V Secondary with a +30° Phase Shift, 130° C Rise
15 HM15T255NCU 97.0% 3–5% 1+3– 130 200 3.9% 45 310 17D
30 HM30T255NCU 97.5% 3–5% 1+3– 130 200 4.5% 45 340 17D
45 HM45T255NCU 97.7% 3–5% 1+3– 130 200 6.6% 45 418 18D
75 HM75T255NCU 98.0% 3–5% 1+3– 130 200 4.7% 50 642 20D
112.5 HM112T255NCU 98.2% 3–5% 1+3– 130 200 5.2% 50 725 21D
150 HM150T255NCU 98.3% 3–5% 1+3– 130 200 5.2% 50 915 22D
225 HM225T255NCU 98.5% 3–5% 1+3– 130 200 6.4% 55 1125 24D
300 HM300T255NCU 98.6% 3–5% 1+3– 130 200 6.6% 55 1535 25D
480 V Delta Primary to 208/120 V Secondary with a +15° Phase Shift, 130° C Rise
15 HM15T251NCU 97.0% 6–2.5% 2+4– 130 200 2.7% 45 310 17D
30 HM30T251NCU 97.5% 6–2.5% 2+4– 130 200 2.4% 45 340 17D
45 HM45T251NCU 97.7% 6–2.5% 2+4– 130 200 4.5% 45 418 18D
75 HM75T251NCU 98.0% 6–2.5% 2+4– 130 200 4.1% 50 642 20D
112.5 HM112T251NCU 98.2% 6–2.5% 2+4– 130 200 4.1% 50 725 21D
150 HM150T251NCU 98.3% 6–2.5% 2+4– 130 200 3.2% 50 915 22D
225 HM225T251NCU 98.5% 6–2.5% 2+4– 130 200 5.6% 55 1125 24D
300 HM300T251NCU 98.6% 4–2.5% 2+2– 130 200 4.9% 55 1535 25D
480 V Delta Primary to 208/120 V Secondary with a -15° Phase Shift, 130° C Rise
15 HM15T259NCU 97.0% 6–2.5% 2+4– 130 200 2.7% 45 310 17D
30 HM30T259NCU 97.5% 6–2.5% 2+4– 130 200 2.4% 45 340 17D
45 HM45T259NCU 97.7% 6–2.5% 2+4– 130 200 4.8% 45 418 18D
75 HM75T259NCU 98.0% 6–2.5% 2+4– 130 200 4.1% 50 642 20D
112.5 HM112T259NCU 98.2% 6–2.5% 2+4– 130 200 4.1% 50 725 21D
150 HM150T259NCU 98.3% 6–2.5% 2+4– 130 200 3.2% 50 915 22D
225 HM225T259NCU 98.5% 6–2.5% 2+4– 130 200 5.6% 55 1125 24D
300 HM300T259NCU 98.6% 4–2.5% 2+2– 130 200 4.9% 55 1535 25D
Catalog No.
Minimum
Efficiency @ 35%
75° C
Full Capacity
Taps
Additional temperature rises are available; for part numbers, see the Schneider Electric Product Configurator.
Degree C
Temp. Rise
Insulation Class %IZ
Sound Level
dB
Weight (lbs)
Enclosure
6
TRANSFORMERS
6-18
© 2019 Schneider Electric
All Rights Reserved