Square D RM17TE00 Data Sheet

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Product data sheet
RM17TE00
multifunction control relay RM17-TE - range
183..528 V AC
Main
Range of product Zelio Control
Product or component type
Relay type Multifunction control relay
Product specific appli­cation
Relay name RM17TE
Relay monitored pa­rameters
Time delay Adjustable 0.1...10 s, 10 %
Switching capacity in VA
Measurement range 183...528 V AC
Modular measurement and control relays
For 3-phase supply
Asymmetry Phase failure detection Phase sequence Undervoltage and overvoltage in window mode
1250 VA
Complementary
Reset time 1500 ms for time delay
Maximum switching voltage 250 V DC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 5 A DC
[Us] rated supply voltage 208...480 V AC 3 phases
Supply voltage limits 183...528 V AC
Control circuit voltage limits - 12 %, + 10 % Un
Power consumption in VA <= 22 VA 400 V AC 50 Hz
Control circuit frequency 50...60 Hz +/- 10 %
Output contacts 1 C/O
Nominal output current 5 A
Hysteresis 2 %
Delay at power up <= 650 ms
Measuring cycle <= 150 ms measurement cycle as true rms value
Threshold adjustment voltage +2...+17 % in the range 480 V AC
Voltage range 480 V phase to phase
Adjustment of asymmetry threshold 5...15 % of Un selected
Measurement accuracy +/- 10 % of the full scale value
Repeat accuracy 3 % for time delay
Measurement error < 1 % over the whole range with voltage variation
Phase failure sensitivity 0.7 Un
Response time < 200 ms in the event of a fault
250 V AC
5 A AC
-2...-12 % in the range 208 V AC
-2...-17 % in the range 220 V AC
2...20 % of Un selected
440 V phase to phase 415 V phase to phase 400 V phase to phase 380 V phase to phase 220 V phase to phase 208 V phase to phase
0.5 % for input and measurement circuit
< 0.05 %/°C with temperature variation
Jul 8, 2016
1
Marking CE : 73/23/EEC
Overvoltage category III conforming to IEC 60664-1
Insulation resistance > 500 MOhm at 500 V DC conforming to IEC 60664-1
[Ui] rated insulation voltage 400 V conforming to IEC 60664-1
Supply frequency 50/60 Hz +/- 10 %
Operating position Any position without
Connections - terminals Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with ca-
Tightening torque 0.6...1 N.m conforming to IEC 60947-1
Housing material Self-extinguishing plastic
Status LED 1 LED yellow for relay ON
Mounting support 35 mm symmetrical DIN rail conforming to EN/IEC 60715
Electrical durability 100000 cycles
Mechanical durability <= 30000000 cycles
Operating rate <= 360 operations/hour under full load
Utilisation category DC-13 conforming to IEC 60947-5-1
Width 17.5 mm
Product weight 0.13 kg
CE : EMC 89/336/EEC
> 500 MOhm at 500 V DC conforming to IEC 60255-5
ble end Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 12, flexible cable with ca­ble end Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end Screw terminals 1 x 0.5...1 x 4 mm² - AWG 20...AWG 11, solid cable without ca­ble end
1 LED green for power ON
DC-12 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-12 conforming to IEC 60947-5-1
Environment
Electromagnetic compatibility Immunity for industrial environments conforming to EN/IEC 61000-6-2
Standards EN/IEC 60255-1
Product certifications CSA
Ambient air temperature for storage -40...70 °C
Ambient air temperature for operation -20...50 °C
Relative humidity 95 % at 55 °C conforming to IEC 60068-2-30
Vibration resistance 1 gn (f = 57.6...150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
Shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1
IP degree of protection IP30 (casing) conforming to IEC 60529
Pollution degree 3 conforming to IEC 60664-1
Dielectric test voltage 2 kV 1 min AC 50 Hz conforming to IEC 60664-1
Non-dissipating shock wave 4 kV conforming to IEC 61000-4-5
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Emission standard for industrial environments conforming to EN/IEC 61000-6-4
C-Tick GL GOST UL
0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
IP20 (terminals) conforming to IEC 60529
2 kV 1 min AC 50 Hz conforming to IEC 60255-5
4 kV conforming to IEC 60664-1 4 kV conforming to IEC 60255-5
Contractual warranty
Period 18 months