Square D LRD3365 Data Sheet

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Product data sheet
LRD3365
TeSys LRD thermal overload relays - 80...104 A - class 10A
Main
Range TeSys
Product name TeSys LRD
Product or component type
Device short name LRD
Relay application Motor protection
Product compatibility LC1D80
Network type AC
Overload tripping class Class 10A conforming to IEC 60947-4-1
Thermal protection ad­justment range
[Ui] rated insulation voltage
Differential thermal overload relay
LC1D95
DC
80...104 A
600 V power circuit conforming to UL 600 V power circuit conforming to CSA 1000 V power circuit conforming to IEC 60947-4-1
Complementary
Network frequency 0...400 Hz
Mounting support Under contactor
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
[Ith] conventional free air thermal current 5 A for signalling circuit
Permissible current 0.06 A at 440 V DC-13 for signalling circuit
[Ue] rated operational voltage 690 V AC 0...400 Hz
[Uimp] rated impulse withstand voltage 6 kV
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Blue push-button for reset mode
Temperature compensation -20...60 °C
Connections - terminals Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness:
Tightening torque Power circuit : 9 N.m - on screw clamp terminals
Height 123 mm
Width 75 mm
Depth 121 mm
Product weight 0.51 kg
Rail with specific accessories Plate with specific accessories
0.72 A at 500 V AC-15 for signalling circuit
Red push-button stop
solid - without cable end Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end Power circuit : screw clamp terminals 1 cable(s) 4...35 mm² - cable stiffness: solid
- without cable end Power circuit : screw clamp terminals 1 cable(s) 4...35 mm² - cable stiffness: flex­ible - with cable end Power circuit : screw clamp terminals 1 cable(s) 4...35 mm² - cable stiffness: flexi­ble - without cable end
Control circuit : 1.7 N.m - on screw clamp terminals
Dec 4, 2015
1
Environment
Standards ATEX D 94/9/CE
Product certifications ATEX INERIS
Protective treatment TH conforming to IEC 60068
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature for operation -20...60 °C without derating conforming to IEC 60947-4-1
Ambient air temperature for storage -60...70 °C
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks 15 Gn for 11 ms IEC 60068-2-7
Dielectric strength 6 kV at 50 Hz conforming to IEC 60255-5
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14
BV CCC CSA DNV GL GOST RINA UL LROS
Vibrations 6 Gn IEC 60068-2-6
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW)
REACh Reference not containing SVHC above the threshold
Product environmental profile
Product end of life instructions Need no specific recycling operations
Compliant - since 0849 - Schneider Electric declaration of conformity
Available Download Product Environmental