Product data sheet
Characteristics
LP2K09103BD
TeSys K reversing contactor - 3P - AC-3 <= 440 V
9 A - 1 NO - 24 V DC coil
Main
Range of product TeSys K
Range TeSys
Product name TeSys K
Product or component type Reversing contactor
Device short name LP2K
Device application Control
Contactor application Motor control
Utilisation category AC-1
Device presentation Preassembled with reversing power busbar
Poles description 3P
Pole contact composition 3 NO
[Ue] rated operational voltage 690 V AC 50/60 Hz for power circuit
[Ie] rated operational current 9 A at <= 440 V AC AC-3 for power circuit
Motor power kW 4 kW at 380...415 V AC 50/60 Hz
Control circuit type DC standard
Control circuit voltage 24 V DC
Auxiliary contact composition 1 NO
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
Resistive load
AC-3
AC-4
<= 690 V AC 50/60 Hz for signalling circuit
20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit
16 A (<= 70 °C) at 690 V AC AC-1 for power circuit
4 kW at 440 V AC 50/60 Hz
4 kW at 480 V AC 50/60 Hz
4 kW at 500...600 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
2.2 kW at 220...230 V AC 50/60 Hz
May 10, 2017
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
1

[Ith] conventional free air thermal
current
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
Rated breaking capacity 110 A at 415 V conforming to IEC 60947
[Icw] rated short-time withstand current 90 A <= 50 °C 1 s power circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
Average impedance 3 mOhm at 50 Hz - Ith 20 A for power circuit
[Ui] rated insulation voltage 690 V for signalling circuit conforming to IEC 60947-4-1
Electrical durability 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
Interlocking type Mechanical
Mounting support Plate
Standards BS 5424
Product certifications CSA
Connections - terminals Spring terminals 1 cable(s) 0.75...1.5 mm² - cable stiffness: solid
Operating time 10 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability 5 Mcycles
Operating rate 3600 cyc/h
20 A at <= 50 °C for power circuit
10 A at <= 50 °C for signalling circuit
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
85 A <= 50 °C 5 s power circuit
80 A <= 50 °C 10 s power circuit
60 A <= 50 °C 30 s power circuit
45 A <= 50 °C 1 min power circuit
40 A <= 50 °C 3 min power circuit
80 A 1 s signalling circuit
90 A 500 ms signalling circuit
110 A 100 ms signalling circuit
20 A <= 50 °C >= 15 s power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
690 V for signalling circuit conforming to IEC 60947-5-1
600 V for signalling circuit conforming to UL 508
600 V for power circuit conforming to CSA C22.2 No 14
600 V for signalling circuit conforming to CSA C22.2 No 14
690 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit conforming to UL 508
1.3 Mcycles 9 A AC-3 at Ue <= 440 V
Rail
IEC 60947
NF C 63-110
VDE 0660
UL
Spring terminals 1 cable(s) 0.75...1.5 mm² - cable stiffness: flexible - without cable end
30...40 ms coil energisation and NO closing
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Complementary
Control circuit voltage limits 0.8...1.15 Uc at <= 50 °C operational
Inrush power in W 3 W at 20 °C
Hold-in power consumption in W 3 W at 20 °C
Heat dissipation 3 W
Auxiliary contacts type Type instantaneous 1 NO
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Non overlap distance 0.5 mm
2
0.1...0.75 Uc at <= 50 °C drop-out

Insulation resistance > 10 MOhm for signalling circuit
Environment
IP degree of protection IP2x conforming to VDE 0106
Protective treatment TC conforming to IEC 60068
Ambient air temperature for operation -25...50 °C
Ambient air temperature for storage -50...80 °C
Operating altitude 2000 m without derating in temperature
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
Height 58 mm
Width 90 mm
Depth 57 mm
Product weight 0.48 kg
TC conforming to DIN 50016
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Shocks contactor opened, on X axis 10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis 6 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on X axis 15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis 10 Gn for 11 ms IEC 60068-2-27
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 0706 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product environmental
Product end of life instructions Available
End of life manual
Contractual warranty
Warranty period 18 months