Characteristics
LC2K0901M7
TeSys K reversing contactor - 3P(3 NO) -AC-3<= 440 V 9 A - 220...230 VAC coil
Oct 19, 2016
1
Main
RangeTeSys
Product nameTeSys K
Product or component
type
Device short nameLC2K
Contactor applicationMotor control
Utilisation categoryAC-1
Device presentationPreassembled with reversing power busbar
Poles description3P
Power pole contact
composition
[Ue] rated operational
voltage
[Ie] rated operational
current
Motor power kW4 kW at 660...690 V AC 50/60 Hz
Control circuit typeAC 50/60 Hz
Control circuit voltage220...230 V AC 50/60 Hz
Auxiliary contact composition
[Uimp] rated impulse
withstand voltage
Overvoltage categoryIII
[Ith] conventional free
air thermal current
Irms rated making capacity
Rated breaking capacity
[Icw] rated short-time
withstand current
Associated fuse rating10 A gG for signalling circuit conforming to VDE
Average impedance3 mOhm at 50 Hz - Ith 20 A for power circuit
Reversing contactor
Resistive load
AC-3
AC-4
3 NO
<= 690 V AC 50/60 Hz for signalling circuit
690 V AC 50/60 Hz for power circuit
16 A (<= 70 °C) at 690 V AC AC-1 for power circuit
20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
4 kW at 500...600 V AC 50/60 Hz
4 kW at 480 V AC 50/60 Hz
4 kW at 440 V AC 50/60 Hz
4 kW at 380...415 V AC 50/60 Hz
2.2 kW at 220...230 V AC 50/60 Hz
1 NC
8 kV
10 A at <= 50 °C for signalling circuit
20 A at <= 50 °C for power circuit
110 A AC for signalling circuit conforming to IEC
60947
110 A AC for power circuit conforming to IEC 60947
110 A AC for power circuit conforming to NF C
63-110
70 A at 660...690 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
20 A <= 50 °C >= 15 s power circuit
110 A 100 ms signalling circuit
90 A 500 ms signalling circuit
80 A 1 s signalling circuit
40 A <= 50 °C 3 min power circuit
45 A <= 50 °C 1 min power circuit
60 A <= 50 °C 30 s power circuit
80 A <= 50 °C 10 s power circuit
85 A <= 50 °C 5 s power circuit
90 A <= 50 °C 1 s power circuit
0660
10 A gG for signalling circuit conforming to IEC
60947
25 A aM for power circuit
25 A gG at <= 440 V for power circuit
2
[Ui] rated insulation
voltage
Electrical durability1.3 Mcycles 9 A AC-3 at Ue <= 440 V
Tightening torque1.3 N.m - on screw clamp terminals - with screwdriv-
Operating time10...20 ms coil de-energisation and NO opening
Safety reliability levelB10d = 20000000 cycles contactor with mechanical
Mechanical durability5 Mcycles
Operating rate3600 cyc/h
600 V for signalling circuit conforming to CSA C22.2
No 14
600 V for power circuit conforming to CSA C22.2 No
14
600 V for signalling circuit conforming to UL 508
690 V for signalling circuit conforming to IEC
60947-5-1
690 V for signalling circuit conforming to IEC
60947-4-1
690 V for power circuit conforming to IEC 60947-4-1
600 V for power circuit conforming to UL 508
0.18 Mcycles 20 A AC-1 at Ue <= 440 V
Rail
IEC 60947
NF C 63-110
VDE 0660
UL
cable stiffness: flexible - with cable end
Screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid
Screw clamp terminals 1 cable(s) 0.34...2.5 mm² cable stiffness: flexible - with cable end
Screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
Screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid
er flat Ø 6 mm
1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
10...20 ms coil energisation and NO closing
load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load
conforming to EN/ISO 13849-1
Complementary
Control circuit voltage limits0.2...0.75 Uc at <= 50 °C drop-out
0.8...1.15 Uc at <= 50 °C operational
Inrush power in VA30 VA at 20 °C
Hold-in power consumption in VA4.5 VA at 20 °C
Heat dissipation1.3 W
Auxiliary contacts typeType instantaneous 1 NC
Signalling circuit frequency<= 400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Non overlap distance0.5 mm
Insulation resistance> 10 MOhm for signalling circuit
3
Environment
IP degree of protectionIP2x conforming to VDE 0106
Protective treatmentTC conforming to DIN 50016
Ambient air temperature for operation-25...50 °C
Ambient air temperature for storage-50...80 °C
Operating altitude2000 m without derating derating in temperature
Flame retardanceRequirement 2 conforming to NF F 16-102
Mechanical robustnessVibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Height58 mm
Width90 mm
Depth57 mm
Product weight0.39 kg
TC conforming to IEC 60068
Requirement 2 conforming to NF F 16-101
V1 conforming to UL 94
Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27
Offer Sustainability
Sustainable offer statusGreen Premium product
RoHS
Product environmental profile
Product end of life instructionsNeed no specific recycling operations
Compliant - since 0706 -Schneider Electric declaration of conformity
Available Download Product Environmental
4
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.