Square D LC1K0910F7 Data Sheet

Page 1
Product data sheet
Characteristics
LC1K0910F7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 110 V AC coil
Range of product TeSys K
Range TeSys
Product or component type Contactor
Product name TeSys K
Device short name LC1K
Device application Control
Contactor application Resistive load
Motor control
Complementary
Utilisation category AC-3
Poles description 3P
Pole contact composition 3 NO
[Ie] rated operational current 9 A at <= 440 V AC AC-3 for power circuit
Control circuit type AC 50/60 Hz
[Uc] control circuit voltage 110 V AC 50/60 Hz
Motor power kW 2.2 kW at 400 V AC 50/60 Hz AC-4
Auxiliary contact composition 1 NO
Overvoltage category III
[Ith] conventional free air thermal current
Sep 21, 2017
AC-4 AC-1
20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit 16 A (<= 70 °C) at 690 V AC AC-1 for power circuit
2.2 kW at 220...230 V AC 50/60 Hz AC-3 4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3
20 A at <= 50 °C for power circuit 10 A at <= 50 °C for signalling circuit
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
1
Page 2
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
Rated breaking capacity 110 A at 415 V conforming to IEC 60947
Associated fuse rating 25 A gG at <= 440 V for power circuit
Average impedance 3 mOhm at 50 Hz - Ith 20 A for power circuit
Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA 30 VA at 20 °C
Hold-in power consumption in VA 4.5 VA at 20 °C
Heat dissipation 1.3 W
Control circuit voltage limits 0.2...0.75 Uc at <= 50 °C drop-out
Operating rate 3600 cyc/h
Auxiliary contacts type Type instantaneous (1 NO)
Signalling circuit frequency <= 400 Hz
Minimum switching current 5 mA for signalling circuit
Minimum switching voltage 17 V for signalling circuit
Operating time 10...20 ms coil de-energisation and NO opening
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Non overlap distance 0.5 mm
Mechanical robustness Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27
110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
0.8...1.15 Uc at <= 50 °C operational
10...20 ms coil energisation and NO closing
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Environment
Product certifications CSA
Protective treatment TC conforming to IEC 60068
Operating altitude 2000 m without derating in temperature
Flame retardance V1 conforming to UL 94
UL
TC conforming to DIN 50016
Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 0640 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product environmental
Product end of life instructions Available
End of life manual
2
Page 3
Contractual warranty
Warranty period 18 months
3