Product specific applicationComplex, high-power machines
Component nameATV71
Motor power kW22 kW at 380...480 V 3 phases
Motor power hp30 hp at 380...480 V 3 phases
Motor cable length
[Us] rated supply voltage380...480 V (- 15...10 %)
Network number of phases3 phases
Line current42 A for 480 V 3 phases 22 kW / 30 hp
EMC filterIntegrated
Assembly styleWith heat sink
Apparent power32.9 kVA at 380 V 3 phases 22 kW / 30 hp
Prospective line Isc<= 22 kA, 3 phases
Nominal output current40 A at 4 kHz 460 V 3 phases 22 kW / 30 hp
Maximum transient current72 A for 60 s 3 phases 22 kW / 30 hp
Output frequency0.1...599 Hz
Nominal switching frequency4 kHz
Switching frequency1...16 kHz adjustable
Asynchronous motor control profileENA (Energy adaptation) system for unbalanced loads
Type of polarizationNo impedance for Modbus
50 A for 380 V 3 phases 22 kW / 30 hp
48 A at 4 kHz 380 V 3 phases 22 kW / 30 hp
79.2 A for 2 s 3 phases 22 kW / 30 hp
4...16 kHz with derating factor
Flux vector control (FVC) with sensor (current vector)
Sensorless flux vector control (SFVC) (voltage or current vector)
Voltage/Frequency ratio (2 or 5 points)
May 01, 2017
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
1
Complementary
Product destinationAsynchronous motors
Supply voltage limits323...528 V
Supply frequency50...60 Hz (- 5...5 %)
Network frequency47.5...63 Hz
Speed range1...100 for asynchronous motor in open-loop mode, without speed feedback
Speed accuracy+/- 0.01 % of nominal speed for 0.2 Tn to Tn torque variation in closed-loop mode with encoder
Torque accuracy+/- 15 % in open-loop mode, without speed feedback
Transient overtorque220 % of nominal motor torque +/- 10 % for 2 s
Braking torque<= 150 % with braking or hoist resistor
Synchronous motor control profileVector control without speed feedback
Regulation loopAdjustable PI regulator
Motor slip compensationAdjustable
Local signalling1 LED red presence of drive voltage
Output voltage<= power supply voltage
InsulationElectrical between power and control
Type of cableWith a NEMA Type1 kit : 3-strand UL 508 cable at 40 °C, copper 75 °C PVC
1...50 for synchronous motor in open-loop mode, without speed feedback
1...1000 for asynchronous motor in closed-loop mode with encoder feedback
feedback
+/- 10 % of nominal slip for 0.2 Tn to Tn torque variation without speed feedback
+/- 5 % in closed-loop mode with encoder feedback
170 % of nominal motor torque +/- 10 % for 60 s every 10 minutes
30 % without braking resistor
Automatic whatever the load
Not available in voltage/frequency ratio (2 or 5 points)
Suppressable
With an IP21 or an IP31 kit : 3-strand IEC cable at 40 °C, copper 70 °C PVC
Without mounting kit : 1-strand IEC cable at 45 °C, copper 70 °C PVC
Without mounting kit : 1-strand IEC cable at 45 °C, copper 90 °C XLPE/EPR
overload and short-circuit protection
Internal supply, 24 V DC, voltage limits 21...27 V, <= 200 mA for overload and short-circuit protection
AI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bits
AI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, impedance 30000 Ohm,
resolution 11 bits
Al2 2 ms, +/- 0.5 ms for analog input(s)
LI1...LI5 2 ms, +/- 0.5 ms for discrete input(s)
LI6 (if configured as logic input) 2 ms, +/- 0.5 ms for discrete input(s)
AO1 2 ms, tolerance +/- 0.5 ms for analog output(s)
R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s)
R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s)
AI2 +/- 0.6 % for a temperature variation 60 °C
AO1 +/- 1 % for a temperature variation 60 °C
AO1 +/- 0.2 %
AO1 software-configurable logic output 10 V <= 20 mA
AO1 software-configurable voltage 0...10 V DC, impedance 470 Ohm, resolution 10 bits
Data format8 bits, 1 stop, even parity for Modbus on front face
Number of addresses1...247 for Modbus
Method of accessSlave for CANopen
MarkingCE
Operating positionVertical +/- 10 degree
Height420 mm
Depth236 mm
Width230 mm
Product weight21 kg
FunctionalityFull
Specific applicationOther applications
Option cardCC-Link communication card
R2A, R2B configurable relay logic NO, electrical durability 100000 cycles
R1, R2 on resistive load, 5 A at 30 V DC, cos phi = 1,
R1, R2 on inductive load, 2 A at 250 V AC, cos phi = 0.4,
R1, R2 on inductive load, 2 A at 30 V DC, cos phi = 0.4,
PWR : safety input 24 V DC, impedance: 1500 Ohm conforming to ISO 13849-1 level d
LI1...LI5 : programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm
LI6 : switch-configurable PTC probe 0...6, impedance: 1500 Ohm
LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 0)
LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 0)
LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 0)
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Drive against input phase loss
Drive break on the control circuit
Drive input phase breaks
Drive line supply overvoltage
Drive line supply undervoltage
Drive overcurrent between output phases and earth
Drive overheating protection
Drive overvoltages on the DC bus
Drive short-circuit between motor phases
Drive thermal protection
Motor motor phase break
Motor power removal
Motor thermal protection
Display unit 0.1 Hz
Modbus
1 RJ45 for Modbus on terminal
Male SUB-D 9 on RJ45 for CANopen
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal
9600 bps, 19200 bps for Modbus on front face
8 bits, odd even or no configurable parity for Modbus on terminal
1...127 for CANopen
Controller inside programmable card
DeviceNet communication card
Ethernet/IP communication card
3
Fipio communication card
I/O extension card
Interbus-S communication card
Interface card for encoder
Modbus Plus communication card
Modbus TCP communication card
Modbus/Uni-Telway communication card
Overhead crane card
Profibus DP communication card
Profibus DP V1 communication card
Environment
Noise level59.9 dB conforming to 86/188/EEC
Dielectric strength3535 V DC between earth and power terminals
Electromagnetic compatibilityConducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3
StandardsEN 55011 class A group 2
Product certificationsCSA
Pollution degree2 conforming to EN/IEC 61800-5-1
IP degree of protectionIP20
Vibration resistance1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-10...50 °C without derating
Ambient air temperature for storage-25...70 °C
Operating altitude<= 1000 m without derating
5092 V DC between control and power terminals
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
EN 61800-3 environments 1 category C3
EN 61800-3 environments 2 category C3
EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3-3 class 3C1
IEC 60721-3-3 class 3S2
UL Type 1
C-Tick
GOST
NOM 117
UL
3 conforming to UL 840
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
5...95 % without dripping water conforming to IEC 60068-2-3
1000...3000 m with current derating 1 % per 100 m
Offer Sustainability
Sustainable offer statusGreen Premium product
RoHS (date code: YYWW)Compliant - since 0946 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REAChReference contains SVHC above the threshold - Go to CaP for more details
Go to CaP for more details
Product environmental profileAvailable
Product environmental
Product end of life instructionsAvailable
Product environmental
Contractual warranty
Warranty period18 months
4
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.