IP degree of protectionIP20 conforming to EN/IEC 61800-5-1
Degree of protectionUL type 1 with UL type 1 conformity kit
Type of coolingFan
Network number of phases1 phase
[Us] rated supply voltage200...240 V (- 15...10 %)
Supply frequency50...60 Hz (- 5...5 %)
Motor power kW2.2 kW for heavy duty
Motor power hp3 hp for heavy duty
Line current23.9 A at 200 V for heavy duty
Prospective line Isc<= 1 kA
Apparent power4.8 kVA at 240 V for heavy duty
Continuous output current11 A at 4 kHz for heavy duty
Maximum transient current16.5 A during 60 s for heavy duty
Asynchronous motor control profileVoltage/Frequency ratio, 2 points
Synchronous motor control profileVector control without sensor
Speed drive output frequency0.1...599 Hz
Synchronous motors
20.1 A at 240 V for heavy duty
Voltage/Frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/Frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Feb 09, 2017
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
1
Page 2
Nominal switching frequency4 kHz
Switching frequency4...16 kHz with current derating
SS1 (safe stop 1)
SMS (safe maximum speed)
SLS (safe limited speed)
GDL (guard door locking)
Modbus
Communication module: CANopen SUB-D 9
Communication module: CANopen open style terminal block
Communication module: EtherCAT RJ45
Communication module: DeviceNet
Communication module: Ethernet/IP
Communication module: Profibus DP V1
Communication module: Profinet
Communication module: Ethernet Powerlink
Complementary
Output voltage<= power supply voltage
Permissible temporary current boost1.5 x In during 60 s for heavy duty
Speed range1...100 with asynchronous motor in open-loop mode
Speed accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
Torque accuracy+/- 15 %
Transient overtorque170...200 % of nominal motor torque
Braking torque< 170 % with braking resistor during 60 s
Regulation loopAdjustable PID regulator
Motor slip compensationAutomatic whatever the load
Refresh timeLogic input (DI1...DI6): 8 ms (+/- 0.7 ms)
Minimum switching currentRelay output (R1, R2): 5 mA at 24 V DC
Maximum switching currentRelay output (R1) on resistive load (cos phi = 1: 3 A at 250 V AC
Specific applicationMachinery
1 LED red for CANopen error
1 LED red for drive fault
188 mm with EMC plate
Bipolar differential voltage (AI2): +/- 10 V DC, impedance 30000 Ohm, resolution 10 bits
Current (AI3): 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration),
impedance 250 Ohm, resolution 10 bits
Programmable as pulse input 20 kpps (DI5): 24...30 V DC: level 1 PLC
Switch-configurable PTC probe (DI6): 24...30 V DC
Safe torque off (STO): 24...30 V DC, impedance 1500 Ohm
Positive logic (source): : DI1...DI6, < 5 V (state 0) > 11 V (state 1)
Analog input AI1, AI2, AI3: +/- 0.5 % for a temperature of 25 °C
Analog output AQ1: +/- 1 % for a temperature of 25 °C
Analog output AQ1: +/- 2 % for a temperature of -10...60 °C
Relay output (R1A, R1B, R1C): 2 ms
Relay output (R2A, R2C): 2 ms
Relay output (R1) on resistive load (cos phi = 1: 4 A at 30 V DC
Relay output (R1, R2) on inductive load (cos phi = 0.4: 2 A at 250 V AC
Relay output (R1, R2) on inductive load (cos phi = 0.4: 2 A at 30 V DC
Relay output (R2) on resistive load (cos phi = 1: 5 A at 250 V AC
Relay output (R2) on resistive load (cos phi = 1: 5 A at 30 V DC
Environment
IsolationBetween power and control terminals
Insulation resistance> 1 mOhm at 500 V DC for 1 minute to earth
Noise level48 dB conforming to 86/188/EEC
Power dissipation in W109.6 W (fan) at 200 V, 4 kHz
Volume of cooling air16 m3/h
Operating positionVertical +/- 10 degree
Electromagnetic compatibilityConducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
3
Page 4
1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
Shock resistance15 gn during 11 ms conforming to EN/IEC 60068-2-27
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-10...50 °C without derating
Ambient air temperature for storage-25...70 °C
Operating altitude<= 1000 m without derating
StandardsEN/IEC 61800-3
Product certificationsCSA
MarkingCE
5...95 % without dripping water conforming to IEC 60068-2-3
RoHS (date code: YYWW)Compliant - since 1610 - Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
REAChReference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
4
Page 5
Product data sheet
Dimensions Drawings
Dimensions
Views: Right - Front - Front with EMC Plate
ATV320U22M2C
5
Page 6
Product data sheet
ATV320U22M2C
Mounting and Clearance
Mounting Types
Mounting Type A: Individual with Ventilation Cover
Only Possible at Ambient Temperature Less or Equal to 50 °C (122 °F)
Mounting Type B: Side by Side, Ventilation Cover Removed
Mounting Type C: Individual, Ventilation Cover Removed
For Operation at Ambient Temperature Above 50 °C (122 °F)
6
Page 7
Product data sheet
ATV320U22M2C
Connections and Schema
Connection Diagrams
Diagram with Line Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with
standard IEC/EN 60204-1.
(1)Line choke (if used)
(2)Fault relay contacts, for remote signaling of drive status
Diagram with Switch Disconnect
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with
standard IEC/EN 60204-1.
(1)Line choke (if used)
(2)Fault relay contacts, for remote signaling of drive status