Square D ATV212HD15N4 Data Sheet

Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Torque accuracy +/- 15 %
Transient overtorque 120% of nominal motor torque +/- 10 % 60 s
Asynchronous motor control profile Flux vector control without sensor, standard
Motor slip compensation Automatic whatever the load
Local signalling DC bus energized 1 LED red)
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit 1 IEC cable 113°F (45°C), copper 90 °C / XLPE/EPR
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.00in² (2.5mm²) / AWG 14
Tightening torque 5.31lbf.in (0.6N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10A overload and
Analogue input number 2
Analogue input type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits
Sampling duration 2ms +/- 0.5 ms F discrete
Response time FM 2 ms +/- 0.5 ms analog
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C
Linearity error VIA +/- 0.15 % of maximum value input
Analogue output number 1
Analogue output type FM switch-configurable voltage 0...10 V DC 7620Ohm 10 bits
Discrete output number 2
Discrete output type Configurable relay logic FLA, FLC) NO - 100000cycles
Minimum switching current 3mA 24 V DC configurable relay logic
Maximum switching current 5A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm
Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Voltage/frequency ratio, 2 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio - Energy Saving, quadratic U/f Voltage/frequency ratio, 5 points
Not available in voltage/frequency ratio motor control Adjustable
Without mounting kit 1 IEC cable 113°F (45°C), copper 70 °C / PVC With UL Type 1 kit: 3 wire(s)UL 508 cable at 40°C, copper 75 °C / PVC
L1/R, L2/S, L3/T terminal 0.04in² (25mm²) / AWG 3
39.83lbf.in (4.5N.m), 40 lb.in L1/R, L2/S, L3/T)
short-circuit protection Internal supply 24 V DC 21…27V), <200A overload and short-circuit protection
VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits VIB configurable PTC probe 0...6 probes 1500 Ohm VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
2ms +/- 0.5 ms R discrete 2ms +/- 0.5 ms RES discrete
3.5ms +/- 0.5 ms VIA analog 22ms +/- 0.5 ms VIB analog
FLA, FLC 7 ms +/- 0.5 ms discrete FLB, FLC 7 ms +/- 0.5 ms discrete RY, RC 7 ms +/- 0.5 ms discrete
+/- 0.6 % VIB) for a temperature variation 60 °C +/- 1 % FM) for a temperature variation 60 °C
VIB +/- 0.15 % of maximum value input FM +/- 0.2 % output
FM switch-configurable current 0...20 mA 970Ohm 10 bits
Configurable relay logic FLB, FLC) NC - 100000cycles Configurable relay logic RY, RC) NO - 100000cycles
5A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) 2A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) 2A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
R programmable 24 V DC level 1 PLC 4700 Ohm RES programmable 24 V DC level 1 PLC 4700 Ohm
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
2
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 3200 s
Braking to standstill By DC injection
Protection type Overheating protection drive
Dielectric strength 3535V DC between earth and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit 0.1 Hz
Communication port protocol BACnet
Connector type 1 open style
Physical interface 2-wire RS 485
Transmission frame RTU
Transmission rate 9600 bps or 19200 bps
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Number of addresses 1…247
Communication service Time out setting from 0.1 to 100 s
Option card Communication card for LonWorks
Operating position Vertical +/- 10 degree
Width 9.65in (245mm)
Height 12.99in (330mm)
Depth 7.48in (190mm)
Net Weight 25.68lb(US) (11.65kg)
Power dissipation in W 625W
Air flow 54420.42Gal/hr(US) (206m3/h)
Functionality Mid
Specific application HVAC
IP degree of protection IP21
Variable speed drive application selection
Motor power range AC-3 15…25kW 380…440V 3 phase
Motor starter type Variable speed drive
Automatic based on the load
Thermal power stage drive Short-circuit between motor phases drive Input phase breaks drive Overcurrent between output phases and earth drive Overvoltages on the DC bus drive Break on the control circuit drive Against exceeding limit speed drive Line supply overvoltage and undervoltage drive Line supply undervoltage drive Against input phase loss drive Thermal protection motor Motor phase break motor With PTC probes motor
5092V DC between control and power terminals
Analog input 0.024/50 Hz
Modbus METASYS N2 APOGEE FLN LonWorks
1 RJ45
Read device identification (43) Monitoring inhibitable Write single register (06) Write multiple registers (16) 2 words maximum Read holding registers (03) 2 words maximum
Compressor for scroll Building - HVAC Fan Building - HVAC Pump Building - HVAC
15…25kW 480…500V 3 phase
Environment
Electromagnetic compatibility Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 Conducted radio-frequency immunity test level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test IEC 61000-4-11
Pollution degree 2 IEC 61800-5-1
IP degree of protection IP20 on upper part without blanking plate on cover EN/IEC 61800-5-1
Vibration resistance 1.5 mm 3…13Hz)EN/IEC 60068-2-6
Shock resistance 15 gn 11ms IEC 60068-2-27
Environmental characteristic Classes 3C1 IEC 60721-3-3
Noise level 54dB 86/188/EEC
Operating altitude 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network
Relative humidity 5…95% without condensation IEC 60068-2-3
Ambient air temperature for operation -10…40°C (without derating)
Ambient air temperature for storage -13…158°F (-25…70°C)
Standards IEC 61800-3 category C2
Product certifications CSA
Marking CE
IP20 on upper part without blanking plate on cover EN/IEC 60529 IP21 EN/IEC 61800-5-1 IP21 EN/IEC 60529 IP41 on upper part EN/IEC 61800-5-1 IP41 on upper part EN/IEC 60529
1 gn 13…200Hz)EN/IEC 60068-2-8
Classes 3S2 IEC 60721-3-3
with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating
5…95% without dripping water IEC 60068-2-3
40…50°C (with derating factor)
EN 61800-3 category C3 IEC 61800-3 category C3 IEC 61800-5-1 EN 61800-3 environments 2 category C1 EN 55011 class A group 1 IEC 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 1 category C3 EN 61800-5-1 UL Type 1 IEC 61800-3 environments 2 category C3 EN 61800-3 category C2 EN 61800-3 environments 1 category C3 IEC 61800-3 EN 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C1 EN 61800-3 IEC 61800-3 environments 2 category C1 EN 61800-3 environments 1 category C1
UL C-tick NOM 117
Ordering and shipping details
Category 22157 - ATV212 1 - 25 HP 460 VOLT
Discount Schedule CP4D
GTIN 00785901944089
Nbr. of units in pkg. 1
Package weight(Lbs) 25.52lb(US) (11.58kg)
Returnability Yes
Country of origin ID
Packing Units
Unit Type of Package 1 PCE
4
Package 1 Height 10.83in (27.5cm)
Package 1 width 15.55in (39.5cm)
Package 1 Length 11.81in (30cm)
Package 2 Weight 131.35lb(US) (59.58kg)
Offer Sustainability
Sustainable offer status Green Premium product
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which
REACh Regulation REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and
is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
EU RoHS Declaration
never end up in rubbish bins.
Contractual warranty
Warranty 18 months
5
Loading...