Spy Tec LR32BOX User Manual

LR32BOX audio recorder
User manual Version 1.02
This recorder let‘s you to record any audio or human conversation in high quality and store all on micro SDHC card. The state of art technology with very low power consumption allows you to record very long records when the battery is powering the module. This recorder is equipped with very high sensitive microphone and wide dynamic range and is able to record conversation from distance over 30 feet (10 meters). All stored recordings are accessible on micro SDHC card by using Record Manager developed for Windows operating system. This software includes fast overview of each record and simple editing functions, including serach for active sound in long records. For protection of stored data it is possible to set password access for all stored recordings. Integrated real time clock should start recording in any specific period of each day or at any specific date. All recorded data are stored with time marks, which gives you very good overview in case of long time recording.
Technical data:
Dimension: 28x33x15mm Battery types: 4x button cell 1.5V, alkaline AG-13 or Zinc Air
ZA675, PR44 Power supply voltage: 3,0-6,0V Maximum recording time: 528 hours (22 days) at 16kHz (with 16GB card) Card type: Micro SDHC card Signal-to-noise ratio: 65dB Sample rate: 22kHz, 16kHz, 11kHz, 8kHz, 5.5kHz Bit width: 16bit Built-in microphone sensitivity: 10-15m Battery life in stand-by mode: 90 days (with alkaline batteries) Voice activated recording yes AGC function: user selectable automatic gain control or fixed
microphone gain Exporting format: by using included software, WAV format Scheduled recording: selectable daily period, week period or calendar Operating mode select: slide switch Microphone type: high quality Knowles EK23 series
Battery life in recording mode for Zinc-Air battery type measured in hours:
Battery life in recording mode for alkaline battery type measured in hours:
For extending battery life should be used voice acitivated recording mode. This option may extend this time significantly.
Operating instructions
For controlling all functions is used one slide switch and multifunctional LED.
Before using the recorder you must have ready formatted SDHC card with FAT32 file system. Card must be formatted with FAT32 file system only and can’t contain any
other files or folders, than image files, created by the recorder and can’t be used by other equipment, like PDA, digital camera, etc... When the card is used for the first time
and doesn't contain any files, the recorder will first create all image files required for the recording. This process will start after you insert the card and turn the slide switch to ON. The LED will start flashing quickly for approximately 2 minutes (depending on a card size, for 32GB card could be a longer time). When it's done, the normal recording will start. Each card contains one or several files named “rcimage.raw”, “rcimage.ra1”, etc. All those files are used by the Record Manager to open your records. Each audio record is stored into those files and no other separate file will appear on the card. Do not remove or insert the card, when the recording or the initial card formatting is in progress.
Start and stop the recording
Before the recording starts, the LED flashing sequence will follow. When the LED flashes 5 times, it means some failure of the micro SD card and the recording didn’t start. When it flashes only ones, the card is full and recording can’t be started. Flashing 2 to 4 times indicates available memory space. (4 flashes – more than 75% space available, 3 flashes – more than 50% space available, 2 flashes – less than 25% space available). The recorder should store up to 255 records. If this count has exceeded, the card is considered as full. When the recording is in progress, the LED makes short flashes each 2 seconds. This function should be disabled for discrete recording. When the voice activated recording is enabled, the LED flashes only, when the sound level is above selected threshold and recording is in progress. The recording is stopped when the card is full or by moving the slide switch to OFF position. Stop sequence is indicated by 3 LED flashes.
Power supply for recorder
The recorder should be powered by small coin cell batteries with any chemistry (Zinc-Air batteries gives the longest recording time in comparing the smallest size). When Zinc-Air batteries are used, the sticker must be removed first. Keep in mind that this type of battery has a self-discharge effect. When the sticker is removed, the batteries are discharging regardless if the battery is inserted in the recorder or not. The usual usage limit is about 2-3 weeks after removing the sticker.
Types of supported SDHC cards
The recorder supports a wide range of micro SDHC cards, however we recommend you to use our included card for best performance. The cards from the other brands should consume more power and this should affect the power consumption significantly in recording mode. Maximum supported card size is 32GB.
Record Manager
The software Record Manager is used for handling all records and configuration of the recorder. All funcions are described in a separate manual for this application. This software is a common application used for all of our recorders and only a configuration (or only a part of the configuration) is a specific part for each recorder type. This part is described below. Before you start changing the configuration, keep in mind all the configuration is stored on microSD card. The recorder will use the new configuration only when the card is inserted back to the recorder and the recorder starts the recording. This is important for the scheduled recording or a real time clock settings to first activate the recording by using a slide switch. This action will not only activate the recording, but it will load the new configuration into the recorder, including the real time synchronization, when it has been saved in a configuration.
All configuration is stored in image file on microSD card. The configuration should be changed in main menu by selecting „Options -> Recorder settings“. This windows is divided into 4 following sections:
The first general part is used to select recording sample rate. To achieve the best quality you should use 16kHz or 22kHz, but this mode takes more power from the battery and will use most of the space for storing the data. For best performance check table showing battery life and memory capacity for each specific mode.
Audio page is used for voice activated recording. When this option is enabled, recorder is recording only when it detects sound above selected threshold level. Minimum level means the highest sensitivity. Delay is specifying the time, for how long recording continues after this sound level is not detected anymore. Recommended value is 5 seconds or more. When LED is enabled to flash during recording, it is flashing only when recording is in progress and not when the recorder is in idle mode waiting for exceeding the selected threshold level. This mode saves significantly the battery energy resulting much longer time of operation. For microphone volume control is implemented AGC function. The recorder should be used in noisy environment or to monitor large rooms, where all silent sounds are required to be recorded. When AGC checkbox is checked, this function is enabled and recorder automatically adjust microphone volume according detected sound level. Maximum microphone volume indicates the maximum volume used by AGC function. When AGC function is disabled, this selected volume is fixed for all the time.
Recorder is equipped with internal real time clock and recording scheduler. If you want to use time activated recording, you can choose from 3 options. Daily timer enables recording
scheduler to start and stop recording at the specified time period, which repeats every day. Single timer is used to start and stop only once at given time and date. The last is weekly timer, where you can specify a different time periods for each day of a week. Every time set to 00:00 is ignored, which enables to schedule recording for example over the midnight. Please note, every time you remove the batteries or the batteries are too weak to operate the recorder, the real time clock is lost and must be synchonized again.
The last part of a configuration contains various options. LED should be disabled in this window to allow discrete mode of operation. Only flashes during recording are disabled. Indication of power up, start and stop sequence is not affected by this option. The real time clock is synchronized according the preset time stored on micro SD card. When you select in this window power-up date and time, this date and time is synchronized inside the recorder when the card is inserted into a recorder and the recorder is powered up by inserting the batteries. All recordings should be password protected by using password protection.
Password protection
When the password protection is enabled and the password is entered, all recorded audio will be protected by using this password. When you open the image file, you’ll have to type correct password to open all audio records.
Export of records
Each record should be exported and stored to your local hard drive in WAV format. To do this, select from one exporting options in main menu „Records“. All records are stored to selected directory, which you can change by menu item „Select directory for export“. Long records should be split into more files. Use option in menu “Records->Maximum size of exported file” to specify maximum size of each exported WAV file.
FAQ:
Q: Can’t start recording – LED flashes only once and the card is not full. A: The card contains 255 records. For next recording you must delete at least last record from the list or format the card.
Q: Card can’t be initialized, LED always flashes 5 times. A: Card is not micro SDHC type or is not properly inserted or the power supply can’t give sufficient current to initialize the card.
Q: The beginning time of recording is incorrect. A: This time is always equivalent to the real time clock, which are synchronized from the card. This problem should happen, when the batteries were removed or the card was removed and clocks are resynchronized again with wrong time.
Q: Recorder was operating and the power source has been suddenly interrupted. A: For this case the last record will be stored properly without any problems.
Loading...