SPX Hankison DHW 13, Hankison DHW 30, Hankison DHW 7, Hankison DHW 35, Hankison DHW 50 Instruction Manual

...
Page 1
INSTRUCTION MANUAL
DHW Series
Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm
FORM NO.: 3215738 R EVISION: 07/2014 READ AND U NDE RSTAND THIS MANUAL PRI OR TO OPERATING OR SERVICI NG THI S PRODUCT.
Page 2
Contents
WARRANTY .......................................................................... 11
IMPORTANT READ PRIOR TO STARTING THIS EQUIPMENT
UNPACKING
This shipment has been thoroughly checked, packed and inspected before leaving our plant. It was received in good condition by the carrier and was so acknowledged.
1) Check for Visible Loss or Damage. If this shipment shows evidence of loss or damage at time of delivery to you, insist that a notation of this loss or damage be made on the delivery receipt by the carrier’s agent.
2) Check for Concealed Loss or Damage. When a shipment has been delivered to you in apparent good order, but concealed damage is found upon unpacking, notify the carrier immediately and insist on his agent inspecting the shipment. Fifteen days from receipt of shipment is the maximum time limit for requesting such inspection. Concealed damage claims are not our responsibility as our terms are F.O.B. point of shipment.
1.0 General Information
CAUTION
A. Pressurized devices-
This equipment is a pressure containing device.
• Donotexceedmaximumoperatingpressureasshown
on equipment serial number tag.
• Makesureequipmentisdepressurizedbeforeworking
on or disassembling it for servicing.
B. Electrical-
This equipment requires electricity to operate.
• Installequipmentincompliancewithnationalandlocal
electrical codes.
C. Breathing air-
• Airtreatedbythisequipmentmaynotbesuitablefor
breathing without further purification. Refer to OSHA standard 1910.134 or other applicable standards for the requirements for breathing quality air.
2
Page 3
2.0 Description
Push to by-pass dryer
2.1 Function
Dual tower regenerative desiccant dryers are utilized to dry compressed air to dew points below the freezing point of water or reduce the moisture content to low levels for use in critical process applications.
Air is dried by using two identical towers, each containing a desiccant bed. While one tower is on-stream drying the com­pressed air, the other tower is off-stream being regenerated (reactivated, i.e., dried out).
Desiccant dryers lower the dew point by adsorbing most of the water vapor present onto the surface of the desiccant. Adsorption occurs until an equilibrium is reached between the partial pressure of the water vapor in the air and that on the surface of the desiccant.
Desiccant can then be regenerated by desorbing the water collected on its surface. Regeneration occurs by expanding a portion of the dried air to atmospheric pressure. This very dry air (called purge air) causes the moisture to desorb from the desiccant and then carries the desorbed water out of the dryer.
2.2 Operation
Compressed air enters the dryer and is directed to TOWER 1 through valve (A) and then exits the dryer through shuttle valve (B). A portion of the dried air is throttled to near atmo­spheric pressure by means of an orifice (C). This extremely dry, low pressure air flows through and regenerates the desiccant in TOWER 2 and is then exhausted through purge/ repressurization valve (D) and exhaust muffler (E) to atmo­sphere.
After a set time, the automatic solid state timer closes purge/repressurization valve (D) allowing TOWER 2 to repres­surize slowly.
At the end of 2 minutes, valve (F) opens and Tower 1 depres­surizes. The main air flow is now dried by TOWER 2 while TOWER 1 is regenerated.
2.3 Air By-Pass Assembly
An optional air by-pass assembly is available for all models. When ordered with the dryer, the by-pass assembly is factory installed inside the dryer cabinet. Make sure the by-pass assembly is in the desired mode: "Dry" (compressed air flow through the dryer) or "By-pass" (compressed air by-passes the dryer).
2.3.1 Models 7 and 13
The by-pass assembly includes a by-pass valve with a manu­ally operated spool. One end of the spool is marked "Push to Dry" and the other end is marked "Push to Bypass". To select the desired mode, remove the locking pin, push and fully depress the appropriately marked end of the spool, and install the locking pin in the opposite end.
Locking Pin
IN
OUT
Figure 2a – Air Bypass Assembly
Models 7 and 13
2.3.2 Models 20, 25, 30, 35, and 50
The by-pass assembly includes two manually operated three­way valves. To select "Dry" mode, rotate the valve handles so that the arrows point away from each other. To select "By-Pass" mode, rotate the valve handles so that the arrows point toward each other.
Dry Mode
Models 7 and 13 Optional by-pass
Push to Dry
C
B
TOWER
1
A
F
TOWER
2
D
E
Figure 1 – Flow Schematic
Models 7 through 50
TOWER
C
B
1
A
F
TOWER
2
D
E
By-Pass Mode
Figure 2b – Air Bypass Assembly
Models 20 through 50
3
Page 4
3.0 Installation
3.1 Dimensions, Connections, Weight
MODEL
NUMBER
7 13 20 25 30 35 50
DIMENSIONS in (mm) CONNECTIONS
A B C D E F H J K M INLET OUTLET
31.09 (790)
31.09 (790)
31.09 (790)
37.94 (964)
37.94 (964)
37.94 (964)
37.94 (964)
2.46
(62.5)
17.52 (445)
17.52 (445)
17.52 (445)
24.37 (619)
24.37 (619)
24.37 (619)
24.37 (619)
E
F
AIR INLET
1.15 (29)
1.15 (29)
1.15 (29)
1.68 (43)
1.68 (43)
1.68 (43)
1.68 (43)
DIFFERENTIAL PRESSURE
INSTRUCTION TAG
15.23 (387)
15.23 (387)
15.23 (387) 21 (533) 21 (533) 21 (533) 21 (533)
INDICATOR
FIELD MOUNTED
PREFILTER
INLET
AUTOMATIC DRAIN
6.69 (170)
6.69 (170)
6.69 (170)
8.54 (217)
8.54 (217)
8.54 (217)
8.54 (217)
ON/OFF SWITCH
TOWER
INDICATING
LIGHTS
3.74 (95)
3.74 (95)
3.74 (95)
6.73 (171)
6.73 (171)
6.73 (171)
6.73 (171)
30.5 (775)
30.5 (775)
30.5 (775)
31.6 (803)
31.6 (803)
31.6 (803)
43.3 (1100)
C D
3.74 (95)
3.74 (95)
3.74 (95)
4.25 (108)
4.25 (108)
4.25 (108)
4.25 (108)
5.31 (135)
5.31 (135)
5.31 (135)
6.22 (158)
6.22 (158)
6.22 (158)
6.22 (158)
27.5 (699)
27.5 (699)
27.5 (699)
27.5 (699)
27.5 (699)
27.5 (699)
39.3 (998)
1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F)
A B
SERIAL
P2
NO. TAG
P1
(INSIDE COVER)
1.69 (43)
H
FIELD MOUNTED
AFTERFILTER
OUTLET
M
PURGE MUFFLER
WEIGHT
lb (kg)
1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F) 1/2" NPT (F)
MOUNTING SLOT DETAIL
55 (25) 60 (27) 71 (32) 93 (42) 93 (42) 99 (45)
132 (60)
1/8" R.
5/8"
1/4" R.
BACK OF ENCLOSURE
ELECTRICAL ENTRY
Maximum Operating Pressure: 150 psig, 10.5 kgf/cm
6' POWER CORD (SEE NOTE 1)
2
Maximum Operating Temperature: 120°F, 49°C
SEE MOUNTING SLOT DETAIL
K
2.36 (60)
NOTE:
1. Dimension "A" applies only to units equipped with optional prefilter and afterfilter package.
2.36 (60)
F
J
Specific dimensions of filters available upon request.
2. Connection sizes valid with or without filters.
3. Weight applies to unit only, add 6-1/2 lbs. (3 kg) to weight for optional filter package when specified.
Figure 3 Dimensional Drawing
4
Page 5
3.2 Electrical Specifications
A
12 1
2C
DESICCANT
DRYER
COMPRESSOR
AFTERCOOLER
SEPARATOR
A
B
D
PREFILTERS
AFTERFILTERS
MODEL WATTS
7 13 20 25 30 35 50
27.5
27.5
27.5
31.8
31.8
33.0
17.0
ELECTRICAL
CONNECTION
L1 L2 E
GROUND
LEGEND
All Models
All Models SW1 On/Off Switch
SOL.1
SOL.2
SOL 1 Left Purge Valve
SOL 2 Right Purge Valve
G
FG S2 A2 FG S1 A2 FG AC1 AC2
1
2
3
4
SOL.1 OUT
SOL.2 OUT
PCB
3.3 Dryer Location in a Compressed Air System
NOTE: Air Compressor should be adequately sized to handle
air system demands as well as purge loss. Failure to take this into account could result in overloading air compressors and/or insufficient air supply downstream.
NOTE: It is desirable to install dryer where compressed air is at the lowest possible temperature (downstream of aftercoolers) and the highest possible pressure (upstream of pressure reducing valves) without exceeding the maximum working pressure.
A. Aftercooler/separator - Compressed air entering dryer
must be cooled to at least 120°F (49°C). Use aftercooler and separator if higher temperatures are present.
G
L1
L2
SW1
Figure 4 Electrical Hook-up
MAIN POWER
NOTE: Installation of a refrigerated dryer ahead of a pres-
sure-swing desiccant dryer does not increase desiccant dryer capacity or reduce purge flow requirements. How­ever, if necessary, a cooling unit can be installed ahead of the desiccant dryer to reduce the inlet air temperature to the dryer, producing a correspondingly lower outlet dew point.
B. Prefilters - Adequate filtration is required upstream of
the dryer in order to protect the desiccant bed from contamination. The following filters are recommended:
1. Air Line Filter - On compressed air systems utiliz­ing non-lubricated (oil-free) air compressors, use to protect desiccant bed from solid and liquid contami­nation. On systems with lubricated compressors, if bulk liquid is present, use as a prefilter ahead of the oil aerosol removal filter.
2. Oil Aerosol Removal Filter - On systems with lubri­cated compressors, use to remove oil aerosols and protect desiccant bed from oil contamination.
C. Desiccant dryer
5
Page 6
D. Afterfilters - To ensure downstream air purity (prevent
desiccant dust from traveling downstream) adequate filtration down-stream of the dryer is required. De­pending on the degree of purity you require from your compressed air system, the following filters are recom­mended:
1. Air Line Filter - Use as an afterfilter to remove desic­cant fines and protect downstream components from solid particles 1 micron and larger. Filters for finer solid particle filtration are available.
2. Oil Vapor Adsorber - Use as an afterfilter to remove oil vapor and its subsequent taste and odor and to protect downstream components from solid particles
0.01 micron and larger.
NOTE: By-pass lines and isolation valves are recom-
mended so that maintenance work can be performed without shutting off the air supply.
IMPORTANT: The compressed air supply inlet should be periodically checked to ensure that equipment design specifications are not exceeded. Normally the compressor installation includes intercoolers, aftercoolers, separators, receivers, or similar equipment which adequately pretreat the compressed air supply in order to avoid excessively high air temperatures and liquid slugging of down-stream equip­ment.
3.4 PreFilter and AfterFilter Installation
If supplied, install Prefilter and Afterfilter.
NOTE: When installing, hold bulkhead fitting on dryer with wrench and thread filter on by hand.
A. Install prefilter (F04-HF-DG1) ahead (upstream) of dryer.
Use nipple supplied to connect filter to inlet port of dryer.
B. Install afterfilter (F04-PF-TG1) downstream of dryer. Use
nipple supplied to connect filter to outlet port of dryer.
NOTE: Observe arrows on differential pressure gauge to ensure proper flow direction through filter.
AFTERFILTER
MUFFLER
To Downstream Air Lines
From Compressor
PREFILTER
NIPPLE NIPPLE
P1
P2
CUSTOMER ASSEMBLY
INSTRUCTIONS
These instructions MUST be followed prior to mounting of dryer enclosure.
1. Connect prefilter and afterfilter to enclosure (if applicable).
2. Mount dryer.
3. Connect to inlet, outlet, and purge connections. (see NOTE)
NOTE: If the equipment is to dry (or reactivate with) a gas
other than air, the outlets of the safety valve, reactivation gas outlet line, blow down valves, etc. are to piped away to a safe location (by purchaser). In piping away gas, do not pipe upward without adequate arrangements to prevent trapping condensation.
4. Install moisture indicator downstream of dryer outlet (if applicable).
3.5 Wall-mounting
Four holes are provided in rear of cabinet. Attach cabinet to wall using four (4) screws. User is responsible for select­ing screws of the appropriate strength and ensuring the wall mounting surface can safely support the weight of the dryer (See Section 3.1).
3.6 Piping
Connect air line from compressor to inlet of prefilter or dryer. Connect downstream air line to outlet of afterfilter or dryer.
3.7 Electrical connection
Check to see that power supply to dryer is the same as the power requirements indicated on the identification label. Install plug into receptacle of proper voltage or hardwire to pigtails and ground screw inside cabinet.
3.8 Muffler Installation
Install muffler (packaged separately inside dryer shipping box) to fitting on side of cabinet.
3.9 Moisture Indicator Installation
Install the moisture indicator (shipped separately inside of cabinet) directly into the pipe line anywhere in air/gas system where moisture level is to be monitored. If indica­tor is installed parallel to main line, make sure enough of a restriction exists in main line to force adequate flow through indicator.
Figure 5
6
3.10 Initial desiccant charge
The dryer is shipped complete with desiccant and ready to operate after piping and electrical connections are made.
Page 7
4.0 Operation
4.1 Start-up
A. During the initial start-up, slowly pressurize dryer to full
line pressure and check entire system for leaks. Depres­surize and correct any leaks.
B. Energize the Dryer On-Off switch located on the enclo-
sure cover (Power-on light should illuminate).
NOTE: If dryer is installed with either internally or externally mounted air by-pass valve, make certain that by-pass valve is closed to prevent untreated air from flowing downstream.
4.2 Inlet, Purge, and Outlet Flows @ 100 psig (7 kgf/cm2)
A. Inlet Flows
1. Maximum Inlet Flow at Rated Conditions For maximum inlet flow at rated conditions refer to
Table 1.
TABLE 1 Inlet and Purge Flows @ 100 psig
MODEL INLET FLOW (1)
-40°F (-40°C) -100°F (-73°C) Average Maximum
7 13 20 25 30 35 50
1. Inlet flows are established in accordance with CAGI (Compressed Air and Gas Institute) standard ADF-200, Dual Stage Regenerative Desiccant Compressed Air Dryers - Methods for Testing and Rating. Conditions for rating dryers are: inlet pressure - 100 psig (7 kgf/cm2); inlet temperature - saturated at 100°F (38°C).
2. Average Purge Flow is the total amount of air used to purge and repressurize off-stream towers averaged over the cycle time. Maximum Purge Flow is the flow rate through the off-stream tower during that portion of the cycle the purge/repressurization valve is open.
7.3 (12) 13 (22) 20 (34) 25 (42) 30 (51) 35 (59) 50 (85)
scfm (m3/h)
5.6 (9.5) 10 (17) 16 (27) 20 (34) 24 (41) 28 (48) 40 (68)
PURGE FLOW (2)
scfm (m3/h)
1.5 (2.5)
2.7 (4.6)
4.2 (7.1)
5.1 (8.7)
6.2 (11)
7.2 (12)
10.2 (17)
2.0 (3.4)
3.7 (6.3)
5.5 (9.3)
6.8 (12)
8.2 (14)
9.6 (16)
13.6 (23)
2. Maximum inlet flow at various pressures To determine maximum inlet flow at inlet pressures
other than 100 psig (7kgf/cm2), multiply inlet flow from Table 1 by multiplier from Table 2 that corre­sponds to system pressure at inlet of dryer.
3. Maximum inlet flow at various temperatures To determine maximum inlet flow at inlet tempera-
tures other than 100°F (38°C), multiply inlet flow from Table 1 by multiplier from Table 3 that corresponds to system temperature at inlet of dryer.
B. Purge Flow
For maximum and average purge flows at 100 psig (7 kgf/cm2) refer to Table 1.
1. Maximum Purge Flow Maximum Purge Flow (MFP) is the amount of purge
flowing through the off-stream tower when the purge/repressurization valve is open. After the purge/ repressurization valve closes, the purge flow will gradually decrease as the off-stream tower repres­surizes to line pressure. Refer to Table 1 for Maximum Purge Flows at 100 psig (7kgf/cm2).
TABLE 2 Capacity Correction Factor for various inlet pressures
INLET
PRESSURE
Multiplier 0.31 0.42 0.54 0.73 0.83 1.00 1.09 1.17 1.26 1.35 1.44
TABLE 3 Capacity Correction Factor for various inlet temperatures
INLET
TEMPERATURE
Multiplier 1.00 0.98 0.96 0.93 0.89
TABLE 4 Purge Flow Correction Factor for various inlet pressures
INLET
PRESSURE
Multiplier 0.55 0.64 0.73 0.82 0.91 1.00 1.09 1.17 1.26 1.35 1.44
TABLE 5 Outlet pressure dew points at Moisture Indicator color change
INLET TEMP. °F
OUTLET P.D.P. °F
psig 50 60 70 80 90 100 110 120 130 140 150
kgf/cm23.5 4.2 4.9 5.6 6.3 7.0 7.7 8.4 9.1 9.8 10.5
°F 100 and below 105 110 115 120
°C 38 and below 41 43 46 49
psig 50 60 70 80 90 100 110 120 130 140 150
kgf/cm23.5 4.2 4.9 5.6 6.3 7.0 7.7 8.4 9.1 9.8 10.5
(°C)
(°C)
35 (2)40(4)50(10)60(16)70(21)80(27)90(32)
-34
-28
(-37)
(-33)
-22
(-30)
100 (38)
-16
-10
(-27)
(-23)-4(-20)3(-16)9(-13)15(-9)21(-6)
110
(43)
120 (49)
7
Page 8
2. Average Purge Flow The Average Purge Flow (APF) is the actual amount of
flow averaged over the entire purge/repressurization cycle. It includes the maximum purge flow (MFP) for a set amount of the purge/repressurization time and the volume of air used for repressurization. Refer to Table 1 for Average Purge Flows at 100 psig.
3. Purge flows at pressures other than 100 psig To determine Maximum or Average Purge Flow at inlet
pressures other than 100 psig, multiply purge flow at 100 psig from Table 1 by the multiplier from Table 4 that corresponds to system pressure at inlet to dryer.
C. Outlet Air Flow
1. Minimum Outlet Flow Determine minimum outlet flow available from dryer
by subtracting Maximum Purge Flow from inlet flow to dryer.
NOTE: Air compressor should be adequately sized to
handle air system demands as well as purge loss. Fail­ure to do so could result in overloading air compres­sors and/or insufficient air supply downstream.
2. Average Outlet Flow Determine average outlet flow available by subtracting
Average Purge Flow from inlet flow to dryer.
NOTE: Average outlet flow may be used to determine
available downstream air supply if a storage vessel (re­ceiver tank) of sufficient volume is available between dryer and point of air usage. Otherwise use 3.2.3.1 To compute downstream air available.
EXAMPLE:
Find maximum inlet flow, maximum and average purge flows, and minimum and average outlet flows for a 13 scfm unit operated at 120 psig. Dryer will operate with an inlet air flow of 14 scfm.
Step 1: Find Maximum Inlet Flow by multiplying Maximum Inlet Flow at Rated Conditions from
Table 1 by Inlet Pressure Correction Factor from Table 2 and Inlet Temperature Correction Factor from Table 3: 13 x 1.17 x 1.00 = 15.2 scfm.
Step 2: Find Maximum Purge Flow by multiplying
Maximum Purge Flow at 100 psig from Table 1 by Purge Flow Correction Factor from Table 4:
3.7 x 1.17 = 4.3 scfm, the maximum purge flow.
Step 3: Find Average Purge Flow by multiplying Average
Purge Flow at 100 psig from Table 1 by Purge Flow Correction Factor from Table 4: 2.7 x 1.17= 3.2 scfm, the average purge flow.
Step 4: Find Minimum Outlet Flow available by subtracting
Maximum Purge Flow (Step 2) from inlet flow of 14 scfm: 14 - 4.3 = 9.7 scfm.
Step 5: Find Average Outlet Flow available by subtracting
Average Purge Flow (Step 3) from inlet flow of 14 scfm: 14 - 3.2 = 10.8 scfm.
4.3 Operating Conditions
A. Maximum Working Pressure: 150 psig (10.5 kgf/cm2)
B. Minimum Working Pressure: 50 psig (3.5 kgf/cm2)
It is recommended that the air dryer be operated at the
highest available pressure not exceeding the maximum working pressure since the dryer capacity increases and % of purge air decreases at higher pressures.
C. Maximum Operating Temperature: 120°F (49°C)
4.4 Operational Check Points
A. Check periodically that there is power to the unit - Power
on light is on.
B. If unit is equipped with optional moisture indicator, check
at least once a day. Outlet relative humidity of the desic­cant dryer is indicated by the color change humidity indi­cator. Green indicates R.H. below 3% and yellow indicates R.H. above 3%. Table 5 indicates outlet dew point when moisture indicator changes from green to yellow at vari­ous inlet temperatures. During startup the indicator may be yellow, however, it should begin to change to green within 4 hours.
C. If supplied with optional prefilter/afterfilter. Check that
indicators are in green area. If indicator is in red area ele­ment replacement is necessary.
4.5 Dryer Shutdown
To shut down the dryer, de-energize using the on-off switch (Power-on light extinguished). Unit will remain pressurized.
4.6 Depressurization
To depressurize unit A. Open by-pass valve (if one is installed) and close inlet and
outlet valves.
B. Run timer through a complete tower change cycle or
until all air has been exhausted from the dryer.
All
Models
All
Models
SOL1 Left Purge Valve Closed Closed Closed Open
SOL2 Right Purge Valve Closed Open Closed Closed
LED Left Tower Flashing On Flashing Off
LED Right Tower Flashing Off Flashing On
8
4 MINUTE CYCLE TIMING CHART
Cycle Time (min:sec)
0:00 - 0:30 0:30 - 2.00 2:00 - 2:30 2:30 - 4:00
Page 9
5.0 Maintenance
CAUTION: The heatless desiccant dryer is a pressure contain­ing device. Depressurize before servicing. (See section 4.6.)
5.1 Desiccant Replacement
IMPORTANT: The use of the correct replacement desiccant
is necessary for proper drying operation. Never use hygro­scopic salts of the type commonly used in “deliquescent” type dryers.
A. Frequency of Desiccant Replacement - Desiccant should
be replaced whenever the required dew point cannot be maintained while the dryer is being operated within its design conditions and there are no mechanical malfunc­tions.
NOTE: Desiccant life is determined by the quality of the
inlet air. Proper filtering of the inlet air will extend the life of the desiccant.
B. Procedure for Desiccant Replacement
1. Depressurize and de-energize the dryer.
2. Remove front panel from cabinet.
3. Disconnect tubing from top and bottom of desic­cant towers and unscrew strainer assemblies. Remove the mounting screws from the outlet shuttle valve mounting bracket to aid in disconnecting the tubing at the top of the towers.
NOTE: Be prepared to catch the desiccant being
removed in a container. Desiccant will readily pour out when bottom strainer is removed.
4. Allow the spent desiccant to drain from the towers.
5. Replace bottom strainer assemblies.
6. Fill the desiccant drying towers as full as possible with dry desiccant.
7. Replace top strainer assemblies.
8. Reinstall tubing to top and bottom of desiccant towers.
C. Ensuring Desiccant Dryness
1. Replacement desiccant is shipped in air tight contain­ers. Keep containers closed until use to avoid mois­ture contamination. If desiccant is exposed to air it can be heated in an oven at 400°F for four hours before use, or the next procedure can be used.
2. If the dryer is not refilled with dry desiccant, it will be necessary to operate the dryer on 100% purge for ap­proximately twenty-four hours to dry the desiccant.
5.2 Prefilter/Afterfilter Maintenance
A. Element Replacement
1. For maximum filtration efficiency, replace element an­nually or when pressure drop reaches 4.3 psi (0.3 bar) (indicator in red area), whichever occurs first.
B. Procedure for Element Replacement
WARNING: THIS FILTER IS A PRESSURE CONTAINING DEVICE. DEPRESSURIZE BEFORE SERVICING.
1. Isolate filter (close inlet and outlet valves if installed) or shut off air supply.
2. Depressurize filter by slowly opening manual drain valve.
3. Remove bowl by unscrewing the bowl from the filter head using hand, strap wrench or C spanner, and pull­ing bowl straight down.
4. Clean filter bowl.
5. Replacing complete element.
a) Pull off old element and discard.
b) Make certain that the old and new element have
the same part number and the end caps are the same color.
c) Wipe the wall inside the filter head to remove any
dirt.
d) Lubricate the new element o-ring on the element
top cap.
e) Align the slot in the element top cap with the pro-
jection inside the filter head.
Projection
Element Slot
Amount of desiccant required for complete change
MODEL DESICCANT REQUIRED
lb (kg)
7 13 20 25 30 35 50
12.8
19.4
28.7
28.7
33.6
47.6
7
(3.2) (5.8)
(8.8) (13.0) (13.0) (15.2) (21.6)
O-Ring
Figure 6
f) Insert the element into the head making sure the
element slot and the projection inside the filter head remain aligned.
NOTE: Handle all elements by bottom end cap only.
9
Page 10
6. Replace housing o-ring (located at the top of the filter bowl) if needed. Make certain o-ring is generously lubricated (Use lubricant provided).
7. Reassemble bowl to head.
NOTE: Threaded bowl to head connection, generously
lubricate threads with a high grade/temperature lubri­cant 150°F (66°C). (Use lubricant provided)
C. Auto Drain Mechanism Replacement
Prefilter only: It is recommended that drain mechanism be replaced annually.
5.3 Repair Parts
7 13 20 25 30 35 50
STRAINER (TOP & BOTTOM) 3209715 3209715 3209715 3209716 3209716 3209716 3209716
SHUTTLE VALVE BODY (OUTLET VALVE) 3244971 3244972 3244973 3244974 3244975 3244976 3244977
SHUTTLE (OUTLET VALVE) 3244978 3244979 3244980 3244981 3244982 3244983 3244984
SHUTTLE VALVE BODY (INLET VALVE) 7433646 7433646 7433647 7433647 7433647 7433647 3247592
SHUTTLE (INLET VALVE) 7433648 7433648 7433649 7433649 7433649 7433649 3247593
SWITCH (ON/OFF) 3245021 3245021 3245021 3245021 3245021 3245021 3245021
CONTROLS TIMER 115V 3247594 3247594 3247594 3247594 3247594 3247594 3247594
CONTROLS TIMER 230V 3247595 3247595 3247595 3247595 3247595 3247595 3247595
PURGE/REPRESSURIZATION VALVE 115V 3209763 3209763 3209764 3209764 3209764 3209764 3247596
PURGE/REPRESSURIZATION VALVE 230V 3209765 3209765 3209766 3209766 3209766 3209766 3247597
MAINTENANCE KIT*
Dryers Made After September 19, 2011 DHWJMKTA DHWJMKTB DHWJMKTC DHWJMKTD DHWJMKTD DHWJMKTE DHWJMKTF
Dryers Made Before September 19, 2011 DHWJMKT1 DHWJMKT2 DHWJMKT3 DHWJMKT4 DHWJMKT5 DHWJMKT6 DHWJMKT7
*MAINTENANCE KITS INCLUDES MUFFLER, CONDENSATE DRAIN, PREFILTER ELEMENT, AFTERFILTER ELEMENT, FILTER O-RINGS (2), DESICCANT
MODEL
10
Page 11
WARRANTY
The manufacturer warrants the product manufactured by it, when properly installed, operated, applied, and maintained in accordance with procedures and recommendations outlined in manufacturer’s instruction manuals, to be free from defects in material or workmanship for a period of one (1) year from the date of shipment to the buyer by the manufacturer or manufacturer’s authorized distributor, or eighteen months from the date of shipment from the factory, whichever occurs first, provided such de­fect is discovered and brought to the manufacturer’s attention within the aforesaid warranty period. The manufacturer will repair or replace any product or part determined to be defective by the manufacturer within the warranty period, provided such defect occurred in normal service and not as a result of misuse, abuse, neglect or accident.
The warranty covers parts and labor for the warranty period. Repair or replacement shall be made at the factory or the instal­lation site, at the sole option of the manufacturer. Any service performed on the product by anyone other than the manufacturer must first be authorized by the manufacturer. Normal maintenance items requiring routine replacement are not warranted. Unau­thorized service voids the warranty and any resulting charge or subsequent claim will not be paid. Products repaired or replaced under warranty shall be warranted for the unexpired portion of the warranty applying to the original product. The foregoing is the exclusive remedy of any buyer of the manufacturer’s product. The maximum damages liability of the manufacturer is the original purchase price of the product or part.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL, OR STATUTORY, AND IS EXPRESSED IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. THE MANUFACTURER SHALL NOT BE LIABLE FOR LOSS OR DAMAGE BY REASON OF STRICT LIABILITY IN TORT OR ITS NEGLIGENCE IN WHATEVER MANNER INCLUD­ING DESIGN, MANUFACTURE OR INSPECTION OF THE EQUIPMENT OR ITS FAILURE TO DISCOVER, REPORT, REPAIR, OR MODIFY LATENT DEFECTS INHERENT THEREIN. THE MANUFACTURER, HIS REPRESENTATIVE OR DISTRIBUTOR SHALL NOT BE LIABLE FOR LOSS OF USE OF THE PRODUCT OR OTHER INCIDENTAL OR CONSEQUENTIAL COSTS, EXPENSES, OR DAMAGES INCURRED BY THE BUYER, WHETHER ARISING FROM BREACH OF WARRANTY, NEGLI­GENCE OR STRICT LIABILITY IN TORT.
The manufacturer does not warrant any product, part, material, component, or accessory manufactured by others
and sold or supplied in connection with the sale of manufacturer’s products.
AUTHORIZATION FROM THE SERVICE DEPARTMENT IS NECESSARY BEFORE MATERIAL IS RETURNED TO THE FACTORY OR
IN-WARRANTY REPAIRS ARE MADE.
SERVICE DEPARTMENT : (724) 746-1100
11
Page 12
DHW SERIES
Pressure Swing Desiccant Compressed Air Dryer
Models 7 through 50 scfm
SPX
1000 Philadelphia Street
Canonsburg, PA 15317-1700 U.S.A.
P: (724) 745-1555
F: (724) 745-6040
E: hankison.americas@spx.com
www.spx.com/hankison
Improvements and research are continuous at SPX.
Specifications may change without notice.
ISSUED 07/2014 Form No.: 3215738 Revision: G
COPYRIGHT ©2014 SPX Corporation
Loading...