SPT WA-6022S, WA-1022S, WA-1222S, WA-8022S User Manual

WINDOW AIR CONDITIONERS
WA-6022S: 6,000 BTU
WA-8022S: 8,000 BTU WA-1022S: 10,000 BTU WA-1222S: 12,000 BTU
MULTI-STEP SPEED ELECTRONIC CONTROL
Important Safety Instructions ..........................1-3
Installation Instructions......................................4-7
Normal Sounds.................................................8
TA B LE O F C O N T E N T S
Air Conditioner Features..............................8-10
Remote Control............................................11-13
Troubleshooting Tip......................................14
Before using your air conditioner, please read this manual carefully and keep it for future reference.
IMPORTANT SAFETY INSTRUCTIONS
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Please note the following symbols:
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Never do this.
WARNING
!
Plug in power plug properly.
Otherwise, it may cause electric shock or fire due to excess heat generation.
!
breaker and a dedicated power circuit.
Incorrect installation may cause fire and electric shock.
!
!
Always ensure proper grounding.
Incorrect grounding may cause electric shock.
!
Do not open the unit during operation
Do not operate or stop the unit by inserting or removing the power plug.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Do not use the socket if it is loose or damaged.
Always do this.
Do not damage or use an unspecified power cord.
It may cause electric shock or fire. If the power cord is damaged, it must be replaced by the manufacturer or an authorised service center or a similarly qualified person in order to avoid a hazard.
Do not direct airflow directly at room occupants.Always install circuit
This is not beneficial to one’s health.
!
Do not modify power cord length or share the outlet with other appliances.
It may cause electric shock or fire due to heat generation.
Unplug unit immediately if strange sound, smell or smoke is emitting from unit.
It may cause electric shock.
!
Keep firearms away.
It may cause fire.
!
If there was a gas leak from another appliance, ventilate the room thoroughly before operating the unit.
It may cause explosion, fire and, burns.
It may cause fire and electric shock.
Keep power cord away from heat sources
It may cause fire and electric shock.
It may cause fire and electric shock.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Do not disassemble or modify the unit.
It may cause failure and electric shock.
1
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
When removing and cleaning the filter, be cautious of sharp edges and corners.
It may cause an injury.
Do not use strong detergent such as wax or thinner to clean the unit.
Appearance may deteriorate due to change of product color or scratching of its surface.
!
Stop operation and close the window during a storm or hurricane.
Opened window may lead to interior damage of furniture, floor, and others.
!
Clean filters once every two weeks. Be sure filter is replaced properly.
Operation without filters may cause failure.
Do not situate a pet or house plant in front of unit’s direct air flow.
This could injure the pet or plant.
Do not clean the air conditioner with water or spray bottle.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
!
Before cleaning and maintenance, be sure power is turned off and plug is disconnected.
Do not clean unit while operating. May cause fire, electric shock or injury.
!
Remove plug from outlet by grasping the plug, never pull on the cord.
It may cause electric shock and damage.
!
Keep room well ventilated if used together with a stove, etc.
An oxygen shortage may occur.
Not intended for special purposes.
Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. May cause deterioration of quality, etc.
!
!
Inspect brackets frequently to ensure no damages occurred due to prolonged exposure to elements.
If bracket is damaged, there is concern of damage due to falling of unit.
!
Unplug from power source if unit is not to be used for a long time.
It may cause failure of product or fire.
Do not block air inlets and outlets.
Do not place heavy object on the power cord and ensure that the cord is not compressed.
It may cause failure of appliance or accident.
!
Use caution when unpacking and installing. Sharp edges can cause injury.
There is danger of fire or electric shock.
!
If water enters the unit, turn the unit off and unplug from outlet. Contact a qualified service technician.
CAUTION
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
2
Do not consume the water drained from the air conditioner.
It contains contaminants and could make you sick.
The appliance shall be installed in accordance with national wiring regulations.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Contact an authorized service technician for repair or maintenance of this unit. Contact the manufacturer or an installer if you have questions regarding installation of this unit.
IMPORTANT SAFETY INSTRUCTIONS
NOTE:
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details. In the event that the power supply cord is damaged, it cannot be repaired, it must be replaced with a cord from the manufacturer.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Do not , un der any circ um stances, cut, remo ve , or bypass the gr ou nding prong.
Power supply c ord with 3 -p rong grounding pl ug and cu rr ent detection dev ice
WARNING
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Your Safety
WARNING
Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
· Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the the cabinet and behind the grille.
· If the air conditioner i s t o b e in stalled in a w indow, yo u w ill pr obably w ant to cl ean both sides of the g lass f irst. I f th e w indow is a tri ple-track ty pe w ith a sc reen pa nel included, remove the screen completely before installation.
· Be sure the air c onditioner h as b een s ecurely a nd c orrectly in stalled a ccording to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
· When handling the air conditioner, be careful to avoid cuts f rom s harp m etal f ins (front and rear coils).
Prevent Accidents
WARNING
Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
· Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
· Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
· Do not run air conditioner without side protective cover in place. This could result in mechanical damage within the air conditioner.
· Do not use an extension cord or an adapter plug.
Electrical Information
Oper ation of Curr ent Device
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this is also indicated by a light on the plug head.)
NOTE:
· Do not use this device to turn the unit on or off.
· Always make sure the RESET button is pushed in for correct operation.
· The power supply must be replaced if it fails to reset when TEST button is pushed or when it cannot be reset. A new one can be obtained from the manufacturer.
· If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the manufacturer.
NOTE: This air conditioner is designed to operate under the following conditions:
Outdoor temp:
Cooling
Indoor temp:
Note: Perfo rmance may be redu ced outside of the se operating t emperatures.
° °
64-109 F/18-43 C
° °
62-90 F/17-32 C
3
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these
instructions for local inspector’s use.
IMPORTANT- Observe all
governing codes and ordinances.
Note to Installer- Be sure to leave these
instructions with the Consumer.
Note to Consumer- Keep these
instructions for futrue reference.
Skill level- Installation of this appliance
requires basic mechanical skills.
Completion time- Approximately 1 hour.
We recommend that two people install this product. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electircian.
When handling the unit, be careful to avoid cuts from sharp metal edges and aluminum fins located on the front and rear coils.
TOOLS YOU WILL NEED
Phillips screwdriver
Leveler
TOOLS YOU MAY USE
WINDOW REQUIREMENTS
Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches(584mm to 914mm). Lower sash must have sufficient vertical opening for installation (Table 1)
OFFSET
EXTERIOR WALL
INNER WINDOW SILL
INTERIOR WALL
Model
Min. Vertica l Opening
WA-6022S/WA-8022S WA-1022S/WA-1222S
14” (356mm)
Table 1
H
Slotted screwdriver
Pencil
Ruler or tape measure
Scissors or knife
NOTE:
Save carton and these installation instructions for future reference. The carton is the best way to store unit during winter or when not in use.
15.5” (394m m)
4
Loading...