SPT
2 8/24/98
SPT9401
ELECTRICAL SPECIFICATIONS
TA = +25 °C, V
CC
= +5.0 V, VIN = 1.0 V
P-P
video signal, RL = 150 Ω, unless otherwise specified.
TEST TEST SPT9401
PARAMETERS CONDITIONS LEVEL MIN TYP MAX UNITS
Power Supply
Supply Current (ICC) No Input I 26.0 35.0 mA
V
CC
Voltage IV 4.5 5.0 5.5 V
Power Dissipation I 130 175 mW
Standby Current Pin 5 Grounded I 22.5 50.0 µA
Standby Power Dissipation Pin 5 Grounded I 113 µW
Digital Input
Digital Input (Low) Standby Pin 5 I 0.0 0.1 0.3 V
Digital Input (High) Standby Pin 5 I 1.8 2.0 V
CC
V
Bias Voltages
Bias Voltage Input Pins 2,4,6 I 2.0 2.3 2.6 V
Dynamic Performance
Voltage Gain I 5.4 5.9 6.4 dB
Total Harmonic Distortion f
IN
= 1 kHz I 0.2 1.0 %
Frequency Response f
IN
= 0.1 to 10 MHz V -0.5 dB
Cross Talk fIN = 1 MHz V -35 dB
ABSOLUTE MAXIMUM RATINGS (Beyond which damage may occur)
(1)
25 °C
Supply Voltages
VCC.......................................................................+6.0 V
Maximum Power Dissipation
P
D
....................................................................................
350 mW
Thermal Impedance (TA=+25 °C and above)
Θ
CA
............................................................................
2.8 mW/°C
Temperature
Operating Temperature ................................. 0 to +70 °C
Storage Temperature................................-55 to +150 °C
Note: 1. Operation at any Absolute Maximum Rating is not implied. See Electrical Specifications for proper nominal
applied conditions in typical applications.
TEST PROCEDURE
100% production tested at the specified temperature.
100% production tested at TA = +25 °C, and sample tested
at the specified temperatures.
QA sample tested only at the specified temperatures.
Parameter is guaranteed (but not tested) by design and
characterization data.
Parameter is a typical value for information purposes only.
100% production tested at T
A
= +25 °C. Parameter is
guaranteed over specified temperature range.
TEST LEVEL
I
II
III
IV
V
VI
TEST LEVEL CODES
All electrical characteristics are subject to the following
conditions:
All parameters having min/max specifications are guaranteed. The Test Level column indicates the specific
device testing actually performed during production and
Quality Assurance inspection. Any blank section in the
data column indicates that the specification is not tested
at the specified condition.