Spring Well CSF1, CSF4 Installation Instructions Manual

Page 1
1
WHOLE HOUSE FILTER &!
SALT-FREE WATER SOFTENER
MODELS: CSF1, CSF4
Installation Instructions
800-589-5592
WWW.SPRINGWELLWATER.COM
You get the best of both worlds when you combine the benefits of our high-tech SpringWell FutureSoft and environmentally-friendly salt-free water softener and our
whole house water filter, which uses the highest quality coconut shell catalytic carbon that targets the contaminants that we find in our water supplies today!
Page 2
"
2
Additional Parts Included
PLEASE READ INSTRUCTIONS FULLY BEFORE INSTALLATION.
Be sure to follow all applicable plumbing codes. The system must be installed on main water supply line.
CAUTION: Do not install on well water unless you have spoken to a customer service representative first.
1. Bypass Valve
2. 1” MNPT Fittings (x2)
3. Mounting Bracket for Pre-Filter
4. Hose Bib Assembly
5. Pre-Filter Housing
6. Spanner Wrench for Pre-Filter Housing
7. O-Ring for Pre-Filter Housing with Lube
8. Sediment Filter
123
4
567
8
Page 3
3
Product Specs
FS1
Tank Width
6”
Tank Height
35” (39” with head)
Service Flow
12 GPM
Max Pressure
75 PSI
Operating Temps
35 - 110 F
Connection Size
1”
For replacement filters, please visit: www.springwellwater.com/replacements
CF1
Tank Width
9”
Tank Height
48” (52” with head)
Flow Rate
9 GPM Service
Connection Size
1”
Operating Pressure
25-80 PSI
Operating Temperatures
36 - 120 F
Pre-Filter Change / Replacement
Every 6-9 Months
Media Change / Replacement
Every 6 Years or 1 Million Gallons
CF4
Tank Width
10”
Tank Height
54” (58” with head)
Flow Rate
11 GPM Service
Connection Size
1”
Operating Pressure
25-80 PSI
Operating Temperatures
36 - 120 F
Pre-Filter Change / Replacement
Every 6-9 Months
Media Change / Replacement
Every 6 Years or 1 Million Gallons
FS4
Tank Width
9”
Tank Height
48” (52” with head)
Service Flow
15 GPM
Max Pressure
75 PSI
Operating Temps
35 - 110 F
Connection Size
1”
Page 4
"
4
Level Tanks
If the tank is not perfectly straight, carefully lift the tank straight up a few inches and
tap it on the ground until the tank stands vertical and fits snuggly into the tank boot.
Page 5
5
Carbon Soak Instructions
IMPORTANT!
The carbon media inside the filter system MUST soak in water for a MINIMUM of 2 days before installation.
To do so set the tank on a level surface in an area where it can get wet around the tank.
Locate the bypass valve with the red arrows and the 1” PVC elbows. Install bypass valve to head of tank hand tight. Be sure the bypass valve is in the “on” position.
Now install PVC elbow to inlet side.
Locate the hose bib assembly and connect it to the Inlet side. Connect a water hose to the opposite end of the hose bib assembly.
Turn the water on slowly to about halfway on and wait until the water comes out of the outlet side. Disconnect the hose and put the bypass valve in bypass mode, then set tank aside in a safe place for 2 days.
Page 6
"
6
FutureSoft Soak Instructions
Set the tank on a level surface in an area where it can get wet around the tank. Locate the bypass valve with the red arrows and the 1” PVC elbows. Install bypass valve to head of tank hand tight. Now install PVC elbow onto the Inlet side. Locate the hose bib assembly and connect it to the Inlet side. Connect a water hose to the opposite end of the hose bib assembly. Put the bypass valve in the “on” position. Turn the water on slowly to about halfway on and wait until water comes out of the Outlet side. Disconnect hose and put the bypass valve in bypass mode, then set tank aside in a safe place for 2 days.
IMPORTANT!
The media inside the filter system MUST soak in water for a MINIMUM of 2 days before installation.
Page 7
"
7
Carbon Rinse Instructions
1. After the carbon has soaked for 2 days take the bypass valve out of
bypass into the service mode.!
2. Locate the hose bib assembly and connect it to the Inlet side. Connect
a water hose to the opposite end of the hose bib assembly.!
3. Turn the water on slowly and only halfway on and allow the water to run
for 15-20 minutes.!
4. Turn water off and disconnect the water hose.
5. Connect water the hose to outlet side and turn the water on slowly to
full strength.
6. Allow water to run for 5 minutes.
7. Disconnect the hose and connect to the inlet side.
8. Turn water on slowly halfway, run for 10 minutes.
9. Disconnect the hose bib assembly.
Note: At this point all of the carbon dust should
be completely out of the carbon bed. However, there can be some residual dust which you will sometimes see in toilets and toilet tanks. This is completely normal and should clear within a day or two.
Page 8
"
8
After the FutureSoft media has soaked for 2 days locate the hose bib assembly again and connect it to the Inlet side of the tank head. Connect a water hose to the opposite end of the hose bib assembly. Put the bypass valve to the in service mode. Turn the water on slowly and only halfway on and allow the water to run for 15-20 minutes. Turn water off and disconnect the water hose. Connect water hose to Outlet side of the filter head and turn water on slowly to full strength. Allow water to run for 5 minutes. Disconnect hose and connect to the Inlet side of the tank head. Turn water on slowly and to halfway on, run for 10 minutes. Disconnect the hose bib assembly.
FutureSoft Rinse Instructions
Page 9
1"5"3"2"4"
9
Pre-Filter Setup/Install
This is the point where you will need to shut the main water supply off and adapt your plumbing in and through the system. We recommend you plumb a shut off valve before the pre-filter housing. Locate the area where
the system is going to be installed. Locate aluminum pre-filter mounting bracket with hex bolts and washers. Mount the pre-filter bracket to the wall (hex bolts into wall with washers). Note that the bracket should be screwed into the
studs in the wall as the weight of the pre-filter once soaked in water will add weight. (approximately 24 pounds) Now connect the pre-filter housing
head to the mounting bracket with the hex bolts provided. Plumb the water from the main water supply into the Inlet side of the pre-filter head. Install lubed o-ring in groove on top of the blue pre-filter housing. Locate pre-filter and install it onto small pipe stand inside the housing. Screw the housing to the head as tight as you can without the pre-filter housing wrench. Now take the wrench and tighten down hand tight
Page 10
10
Complete Install
Once the plumbing is complete its time to start the system up. Double check all connections. The valve nuts should only be hand tight. Slowly turn the main water supply back on. Check for leaks. If there are no leaks slowly turn the bypass valves to the on position. Go to a faucet inside and slowly turn the cold water on about halfway and let it run for about 5 minutes. Turn off the faucet and you have now completed the install.
Now you can enjoy your new Whole House Water Filtration System &
(Example using SharkBite Fittings)
Page 11
11
Warranty Information
For more information on our warranty, please visit www.springwellwater.com/warranty/