Spreco Silentwind Instruction For Use & Installation Instructions

instructions for use / installation manual
SILENTWIND
2
We thank you having bought our product . You have decided on a new generation of windgenerator. Compared to traditional windgenerators the essential advantages of our product are safety, security, efficiency and very little noise emission. You will also profit from our experience of more than 30 years with various windgenerators used offshore sailing. For long distance cruising the availability of electric energy without the possibility of grid connection is essential .
Fair winds at any time
The Spreco Team
Please note that this manual is part of the product and must be read closely. Please study the information carefully before installing the Silentwind generator. This manual should always be kept near the product and passed on to future owners.
This manual is addressed to the person installing the Silentwind generator. This person should be familiar with electric wiring and the use of appropiate tools. Otherwise the Silentwind generator should be installed by a specialist.
3
Contents:
1. Operation and use 4
2. Safety instructions 4
2.1. Mechanical risks 5
2.2. Electrical risks 6
2.3. Installation risks 6
3. Technical data 6
3.1. Windgenerator 6
3.1.1. Electrical data 6
3.1.2. Mechanical data 6
3.2. Charge controller 6
3.2.1 Electrical data 7
3.2.2 Mechanical data 7
3.3. Dimensions 7
3.4. Power diagram 8
4. List of enclosed parts 8
5. Operation description 9
6. Diameters of cables 9
7. Installation 9
8. Getting started 11
9. Run and stop 12
10. Charging indicator 12
11. Check ups 12
11.1. Blades 12
11.2. Screw terminals 13
11.3. Bearings / Gaskets 13
11.4. Corrosion protection 13
11.5. Mounting construction 13
11.6. Electrical system 13
12. Maintenance 13
13. Trouble shooting 14
14. Attachment / sketches 16
15. Warranty 19
16. Warranty note 21
4
1. Operation and use
It´s most efficient to use the regenerative electric sources of both wind and sun combined to charge your batteries so that you can make use of daylight and wind for 24 hours. Our hybrid charge regulator is suitable for both sources. You can also charge the batteries of an electric vehicle with this unit. Further applications are: Any application without grid connection, research units, traffic management systems, emergency systems, street lamps, billboard illumination, projects in developing countries, wireless LAN access points, holiday homes with inverters for independent provision of electricity wherever there is no grid connection available or too complicated to install. The Silentwind generator is ultralight and aerodynamic so that it is possible to connect various windgenerators in case your need for energy is high. As noise emission is very low you can opereate the Silentwind generator in neighbourhoods and on sailing yachts without annoying your neighbours. Our charge regulater is suitable both for 12 and 24 volt usage and can be connected to the Silentwind generator and solar panel. Another advantage of the Silentwind generator ist hat it does not have any inbuilt electronics which means that there is hardly any maintenance work on the mounted windgenerator. The electric power is led down to the charge regulator by three cables. The hand laminated carbon fiber blades were successfully tested in a wind tunnel up to wind speeds of 35m/s 63 knots according to DIN EN 61400-2. Therefor you need not worry about the Silentwind generator in any storm conditions. For maintenance work there is an additional manual stop switch.
2. Safety instructions
Due to the high RPM and the electric energy that windgenerators generate their use may be dangerous. Therefore carefully read the following safety instructions.
2.1. Mechanical risks
For various reasons the turning rotor system must be handled with caution. You cannot see the end of the blades in high wind speeds so that you do not recognise the inherent danger. Due to their aerodynamic shape the blades have very sharp edges that may hurt you in high wind conditions. Never ever try to touch the
turning rotor system ! Never ever try to stop the turning rotor system manually.
Make sure that you install the windgenerator in a position that nobody can touch the blades. Especially on boats ensure a sufficient height above deck. The blades are produced from carbon fibre which is extremely solid even in high wind speeds. Therefore keep away from the turning blades in any case. However they can break because of ropes or other parts touching the blades in very strong winds. If one of the blades is damaged, activate the brake function manually with the stop switch of the charge regulator. If one of the blades is damaged, the rotor system will be out of balance which may be a risk for the whole mounting construction. This has to be considered before mounting the windgenerator in a safe position.
5
Before you install the windgenerator on a mast construction make sure that the 3­phase wiring is disconnected from the charge regulator or fix one blade so that the system cannot turn. You can also connect the 3 AC wires to block the system whilst mounting. Another possibility to install the system is to screw the hub with the blades to the shaft at the very end of the mounting procedure. The mast must be well fixed so that it is safe in strong wind and sea conditions. Please ask a professional who is able to assess the load that the system generates in strong wind conditions.
2.2. Elecrical risks
An idle running windgenerator can generate an AC voltage of 40 volt AC /15amp per phase. Only connect all components if you are familiar with electric wiring. The high voltage can cause serious injuries and fire if you do not pay attention to safety. Never ever touch the open end of the wires. The currents on charging the batteries can reach more than 30 A DC. The whole wiring electric components and connection points must be able to carry a current of 40 A. Find information about suitable cable dimensions on page 9
Warning: Wires with insufficient diameters can cause fire.
Make sure that the wires are run so that mechanical damages cannot occur. A damaged cable is a severe safety risk. Install a fuse to the batteries positive pole as closel as possible to the battery. In any case a short circuit of the poles must be avoided.
Warning: A short circuit can cause fire and explosion. Never ever install batteries where sparks can cause this risk. Always ensure sufficient ventilation!
The electrical installation should be carried out by persons with suitable skills who know what they do. Before a storm the Silentwind generator should be manually stopped with the stop switch on the charge regulator. In case of storms we recommend to fix one rotorblade to the mast because of the risk of flying objects.
6
2.3. Installation risks
Only use mounting constructions that can take the load of the generator and the blast pressure of the wind in any condition.
Working on the mounting unit should only be carried out on a calm day. Make sure that nobody is close to the mast.
Disconnect the battery from the charge regulator when working at the system. The turning of the blades must be avoided by fixing one blade to the mast.
3. Technical data
3.1. Windgenerator
3.1.1. Electrical data
Type of generator
Permanent magnet generator, 3 phases, Neodymium-magnets Rated voltage
12 VDC Rated power
400 Watt Rated peak power at
13,5 m/s Start up speed
2,2 m/s Start of charging
3 m/s Charge indicator
Blue LED on the buttom of housing
3.1.2. Mechanical date
Safety test in wind tunnel
122 km/h without failure Rotordiameter
1,15m Number of blades
3 Weight of blades
140g/blade Material of blades
Carbon fibre, hand laminated RPM range
480 – 1420 RPM weight
6,8kg (Generator) Package dimensions
740x370x220mm weight: 9,8kg Colour
white RAL 9010, powder coated Warranty
36 months
3.2. Charge regulator
Charge and power management of the provided external hybrid-charge controller Type 1: W+S 1 Maximum voltage adjustable for acid, gel and AGM batteries. Brake mode: electronically or manually with inbuilt Stopp switch for maintenance work (see enclosed manual)
7
3.2.1. Electrical data
System voltage
12/24 VDC Max. input current windgenerator
30 A Max. input current solar
10 A ( 100Wp) LCD + LED displays
W, V, A, kWh, Ah, load data
3.2.2 Mechanical data
weight
1,15kg (regulator) Package dimensions
190x120x65mm Warranty
24 months
3.3. Dimensions
Loading...