Sprayon SC2302000 User Manual

EL™2302 Electronic Contact Cleaner Aerosol
Not available. Aerosol.
US / Canada: (216) 566-2917 Mexico: SETIQ 01-800-00-214-00 / (52) 55-5559-1588 24 hours / 365 days a year
SAFETY DATA SHEET
Section 1. Identification
:
: :
:
:
Sprayon Products Group 101 W. Prospect Avenue, Cleveland, Ohio 44115
Relevant identified uses of the substance or mixture and uses advised against
Paint or paint related material.
SC2302000
SC2302000
:
:
US / Canada: (800) 247-3266 Mexico: Not Available
:
US / Canada: (216) 566-2902 Mexico: Not Available
:
US / Canada: (800) 424-9300 Mexico: SETIQ 01-800-00-214-00 / (52) 55-5559-1588 24 hours / 365 days a year
Section 2. Hazards identification
FLAMMABLE AEROSOLS - Category 1 GASES UNDER PRESSURE - Compressed gas SKIN CORROSION/IRRITATION - Category 2 SERIOUS EYE DAMAGE/ EYE IRRITATION - Category 2A SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Respiratory tract irritation) - Category 3 SPECIFIC TARGET ORGAN TOXICITY (SINGLE EXPOSURE) (Narcotic effects) ­Category 3 SPECIFIC TARGET ORGAN TOXICITY (REPEATED EXPOSURE) - Category 2 ASPIRATION HAZARD - Category 1
:
Signal word
:
Danger
Hazard pictograms
:
GHS label elements
Percentage of the mixture consisting of ingredient(s) of unknown oral toxicity: 8% Percentage of the mixture consisting of ingredient(s) of unknown dermal toxicity: 57.9% Percentage of the mixture consisting of ingredient(s) of unknown inhalation toxicity: 50%
:
This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200).
Date of issue/Date of revision
:
4/12/2019
Date of previous issue
:
6/13/2018
Version
:91/15
SC2302000
EL™2302 Electronic Contact Cleaner Aerosol
SHW-85-NA-GHS-US
Section 2. Hazards identification
Precautionary statements
Prevention
:
Wear protective gloves. Wear eye or face protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not spray on an open flame or other ignition source. Use only outdoors or in a well-ventilated area. Do not breathe dust or mist. Wash hands thoroughly after handling. Pressurized container: Do not pierce or burn, even after use.
Response
:
Get medical attention if you feel unwell. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or physician if you feel unwell. IF SWALLOWED: Immediately call a POISON CENTER or physician. Do NOT induce vomiting. IF ON SKIN: Wash with plenty of soap and water. Take off contaminated clothing and wash it before reuse. If skin irritation occurs: Get medical attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical attention.
Storage
:
Store locked up. Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F. Store in a well-ventilated place.
Disposal
Dispose of contents and container in accordance with all local, regional, national and international regulations.
:
None known.
Extremely flammable aerosol. Contains gas under pressure; may explode if heated. Causes serious eye irritation. Causes skin irritation. May be fatal if swallowed and enters airways. May cause respiratory irritation. May cause drowsiness or dizziness. May cause damage to organs through prolonged or repeated exposure.
:
Hazard statements
Please refer to the SDS for additional information. Keep out of reach of children. Keep upright in a cool, dry place. Do not discard empty can in trash compactor.
Supplemental label elements
DELAYED EFFECTS FROM LONG TERM OVEREXPOSURE. Contains solvents which can cause permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents can be harmful or fatal. WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. FOR INDUSTRIAL USE ONLY.
:
Section 3. Composition/information on ingredients
Ethanol
≥25 - ≤50
64-17-5
Methyl Acetate
≥10 - ≤25
79-20-9
Light Aliphatic Hydrocarbon Solvent
≥10 - ≤25
64742-49-0
Carbon Dioxide
≤10
124-38-9
2-Propanol
≤10
67-63-0
Lt. Aliphatic Hydrocarbon Solvent
≤3
64742-89-8
Methyl Cyclohexane
≤3
108-87-2
Ingredient name
CAS number
% by weight
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health and hence require reporting in this section.
:
Not available.
CAS number/other identifiers
:
Occupational exposure limits, if available, are listed in Section 8.
Mixture
Any concentration shown as a range is to protect confidentiality or is due to batch variation.
Date of issue/Date of revision
:
4/12/2019
Date of previous issue
:
6/13/2018
Version
:92/15
SC2302000
EL™2302 Electronic Contact Cleaner Aerosol
SHW-85-NA-GHS-US
Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Aspiration hazard if swallowed. Can enter lungs and cause damage. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Section 4. First aid measures
Eye contact
Skin contact
Inhalation
Ingestion
:
:::
Notes to physician
:
Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Description of necessary first aid measures
Specific treatments
:
No specific treatment.
Most important symptoms/effects, acute and delayed
Inhalation
:
Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness. May cause respiratory irritation.
Can cause central nervous system (CNS) depression. May be fatal if swallowed and enters airways.
:
Ingestion Skin contact
:
Causes skin irritation.
Causes serious eye irritation.
:
Eye contact
Over-exposure signs/symptoms
Skin contact Ingestion
Inhalation
Adverse symptoms may include the following: respiratory tract irritation coughing nausea or vomiting headache drowsiness/fatigue dizziness/vertigo unconsciousness
Adverse symptoms may include the following: nausea or vomiting
Adverse symptoms may include the following: irritation redness
:
:
:
Eye contact
:
Adverse symptoms may include the following: pain or irritation watering redness
Potential acute health effects
Indication of immediate medical attention and special treatment needed, if necessary
Date of issue/Date of revision
:
4/12/2019
Date of previous issue
:
6/13/2018
Version
:93/15
SC2302000
EL™2302 Electronic Contact Cleaner Aerosol
SHW-85-NA-GHS-US
Section 4. First aid measures
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation.
See toxicological information (Section 11)
Section 5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Hazardous thermal decomposition products
Decomposition products may include the following materials: carbon dioxide carbon monoxide
Extremely flammable aerosol. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed.
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Use an extinguishing agent suitable for the surrounding fire.
Extinguishing media
:
: :
None known.
Suitable extinguishing media
:
Unsuitable extinguishing media
:
:
Section 6. Accidental release measures
Environmental precautions
Personal precautions, protective equipment and emergency procedures
:
:
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. In the case of aerosols being ruptured, care should be taken due to the rapid escape of the pressurized contents and propellant. If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Small spill
:
Methods and materials for containment and cleaning up
For non-emergency personnel
For emergency responders
:
If specialized clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For non­emergency personnel".
Date of issue/Date of revision
:
4/12/2019
Date of previous issue
:
6/13/2018
Version
:94/15
SC2302000
EL™2302 Electronic Contact Cleaner Aerosol
SHW-85-NA-GHS-US
Section 6. Accidental release measures
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.
Large spill
:
Section 7. Handling and storage
Advice on general occupational hygiene
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Store in accordance with local regulations. Store away from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Protect from sunlight. Store locked up. Eliminate all ignition sources. Use appropriate containment to avoid environmental contamination. See Section 10 for incompatible materials before handling or use.
:
:
Protective measures
Put on appropriate personal protective equipment (see Section 8). Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use. Do not breathe vapor or mist. Do not swallow. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous.
:
Precautions for safe handling
Ethanol
ACGIH TLV (United States, 3/2018).
STEL: 1000 ppm 15 minutes.
NIOSH REL (United States, 10/2016).
TWA: 1000 ppm 10 hours. TWA: 1900 mg/m³ 10 hours.
OSHA PEL (United States, 5/2018).
TWA: 1000 ppm 8 hours. TWA: 1900 mg/m³ 8 hours.
Methyl Acetate
ACGIH TLV (United States, 3/2018).
TWA: 200 ppm 8 hours. TWA: 606 mg/m³ 8 hours. STEL: 250 ppm 15 minutes. STEL: 757 mg/m³ 15 minutes.
NIOSH REL (United States, 10/2016).
TWA: 200 ppm 10 hours. TWA: 610 mg/m³ 10 hours. STEL: 250 ppm 15 minutes. STEL: 760 mg/m³ 15 minutes.
OSHA PEL (United States, 5/2018).
TWA: 200 ppm 8 hours. TWA: 610 mg/m³ 8 hours.
Light Aliphatic Hydrocarbon Solvent
None.
Carbon Dioxide
ACGIH TLV (United States, 3/2018). Oxygen
Section 8. Exposure controls/personal protection
Ingredient name
Exposure limits
Control parameters
Occupational exposure limits (OSHA United States)
Date of issue/Date of revision
:
4/12/2019
Date of previous issue
:
6/13/2018
Version
:95/15
SC2302000
EL™2302 Electronic Contact Cleaner Aerosol
SHW-85-NA-GHS-US
Loading...
+ 10 hidden pages