SPL Crossover User Manual

Professional Fidelity
Mastering Grade Listening
Crossover – Quickstart
Active analog -way crossover
User manual and additional information: spl.audio
EN
Crossover – Quickstart Crossover – Quickstart
LOW OUTPUT
LOW OUTPUT
Serial
Number
Made in Germany
Crossover
~ 115V AC / ~230V AC, 50 Hz / 60 Hz, P max. 50 W
AVIS: RISQUE DE CHOC ÉLEC TRIQUE • NE PAS OUVRIR
RISK OF ELECTRIC SHOC K
DO NOT OPEN
CAUTION
RL RL RL
L
L
RLR
INPUT
INPUT
1 3
2 4
Connect to SPL Performer Amplifier (s) for remote power on/off
AMP CTL/ 12V TRIGGER
AMP CTL/ 12V TRIGGER
IN OUT OUT
MID-HI OUTPUT
MID-HI OUTPUT
LR
RCA
230V AC:
T 630mA
L 250 V
115V AC:
T 1.2 A
L 250 V
FUSE
FUSE
R
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over
4. Reinstall
VOLTAGE SELECTION
VOLTAGE SELECTION
VOLTAiR
120V DC Audio Rail
ON
LOW CUT
StereoMono
2412
PHASE
LOW MID-HI
5
0
6
0
7
0
8
5
1
0
0
1
2
0
ROLL-OFF
| dB
Crossover
X-OVER
OUT
20HzOffOnOff
VU
MID-HILOW
Input
Active Crossover
0
1
8
0
L
O
W
L
E
V
E
L
|
d
B
X
-
O
V
E
R
|
H
z
5
0
6
0
7
0
8
5
1
0
0
1
2
0
X
-
O
V
E
R
|
H
z
P
H
A
S
E
|
Ø
°
-
1
0
-
9
.
5
-
8
.
5
-
6
.
7
-
5
.
2
-
4
.
2
-
3
.
2
-
2
.
3
-
1
.
5
-
0
.
5
0
1
.
0
1
.
6
2
.
5
3
.
5
4
.
5
5
.
5
6
.
7
8
.
0
9
.
5
1
0
VU
120
6
Var
-180°
Var
Off
AMP CTL Input
10
Start up
Read the security advices on page !
Make sure that the selected mains voltage of the Crossover is according to the mains voltage of your region.
Make sure that the mains switch on the rear of the Crossover is set to O (O=O/On=I).
The standby switch on the front panel has to be set to
(standby).
Connect the supplied power cord to the Crossover and an appropriate mains socket outlet.
If the supplied power cord does not match your mains socket outlet, please contact your dealer.
Turn o all devices you wish to connect to the Crossover.
With the RCA button on the rear you select the RCA input. If pressed, the RCA input is active, otherwise the XLR input is used. Connect the outputs of your preamplier to the inputs of the Crossover. Please use appropriate audio cables (XLR, RCA).
Audio cables not included in the scope of delivery.
Connect the input of your subwoofer power amplier(s) to the LOW Output of the Crossover.
You can connect a stereo, two mono or one mono power amplier to the Crossover. In case of a mono subwoofer application, switch the LOW Mono/Stereo Switch to Mono – both LOW Outputs L and R feed the mono signal. Audio cables not included in the scope of delivery.
Connect the input of your main power amplier(s) to the MID-HI Output of the Crossover.
Audio cables not included in the scope of delivery.
If you own an SPL device supporting AMP CTL output(s) you can trigger standby and operation. Therefore connect the AMP CTL output of the SPL device with a mono mini jack cable to the AMP CTL input of the Crossover.
The Standby switch has to be set to ON in order to control the Crossover Standby via AMP CTL. Mono mini jack cable not included in the scope of delivery.
You may also use other V trigger controller. The Crossover is in operation mode when a switching voltage of  Volt DC is applied to the AMP/CTL input. As soon as the  Volt DC is removed, the Crossover switches back to standby mode. Use a mono mini jack cable where the tip is plus and the sleeve is minus.
1
2
3
4 5
6
7
8
9
10
Tip Sleeve
XLR Audio Inputs
MID-HI Output
Standby Switch
LOW Output
Mains Voltage
Mains Switch
Mains Connector
LOW Mono/Stereo Switch
RCA Input Selector
7
9
104
8
2
3
EN
DE
5
8
7
Crossover – Quickstart Crossover – Quickstart
VOLTAiR
120V DC Audio Rail
ON
LOW CUT
StereoMono
2412
PHASE
LOW MID-HI
5
0
6
0
7
0
8
5
1
0
0
1
2
0
ROLL-OFF
| dB
Crossover
X-OVER
OUT
20HzOffOnOff
VU
MID-HILOW
Input
Active Crossover
0
1
8
0
L
O
W
L
E
V
E
L
|
d
B
X
-
O
V
E
R
|
H
z
5
0
6
0
7
0
8
5
1
0
0
1
2
0
X
-
O
V
E
R
|
H
z
P
H
A
S
E
|
Ø
°
-
1
0
-
9
.
5
-
8
.
5
-
6
.
7
-
5
.
2
-
4
.
2
-
3
.
2
-
2
.
3
-
1
.
5
-
0
.
5
0
1
.
0
1
.
6
2
.
5
3
.
5
4
.
5
5
.
5
6
.
7
8
.
0
9
.
5
1
0
VU
120
6
Var
-180°
Var
Off
LOW OUTPUT
LOW OUTPUT
Serial
Number
Made in Germany
Crossover
~ 115V AC / ~230V AC, 50 Hz / 60 Hz, P max. 50 W
AVIS: RISQUE DE CHOC ÉLEC TRIQUE • NE PAS OUVRIR
RISK OF ELECTRIC SHOC K
DO NOT OPEN
CAUTION
RL RL RL
L
L
RLR
INPUT
INPUT
1 3
2 4
Connect to SPL Performer Amplifier (s) for remote power on/off
AMP CTL/ 12V TRIGGER
AMP CTL/ 12V TRIGGER
IN OUT OUT
MID-HI OUTPUT
MID-HI OUTPUT
LR
RCA
230V AC:
T 630mA
L 250 V
115V AC:
T 1.2 A
L 250 V
FUSE
FUSE
R
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over
4. Reinstall
VOLTAGE SELECTION
VOLTAGE SELECTION
VU Meter
14 1813
AMP CTL Output
AMP CTL Input
11
16
If you own SPL Performer power ampliers or other ampliers using V trigger inputs you can connect the AMPCTL outputs of the Crossover with mono mini jack cables to the AMP CTL of the ampsto trigger on and standby. Up to  ampliers can be triggered together.
Mono mini jack cable not included in the scope of delivery.
Power up
Turn down the volume of the connected devices.
Switch on mains switch on the back of the Crossover (On = I).
The right VU Meter is dimly lit red.
Operation
Switch the Crossover from standby into operation by setting the standby switch to ON.
Both VU Meters now lights up brightly.
Standby
Switch the Crossover into standby by setting the standby switch to ( = Standby).
If the Crossover is connected via AMP CTL input with an SPL device supporting AMP CTL output(s), the Crossover is triggered between standby and operation together with the SPL device.
The Standby Switch has to be set to ON in order to control the Crossover Standby via AMP CTL.
Power down
Turn down the volume of the connected devices.
Switch o mains switch on the rear of the Crossover (O = O).
The VU Meters no longer lights up.
11
12
13
14
15
16
17
18
Standby Switch
Mains Switch
1514
13 18
EN
DE
Crossover – Quickstart Crossover – Quickstart
VOLTAiR
120V DC Audio Rail
ON
LOW CUT
StereoMono
2412
PHASE
LOW MID-HI
5
0
6
0
7
0
8
5
1
0
0
1
2
0
ROLL-OFF
| dB
Crossover
X-OVER
OUT
20HzOffOnOff
VU
MID-HILOW
Input
Active Crossover
0
1
8
0
L
O
W
L
E
V
E
L
|
d
B
X
-
O
V
E
R
|
H
z
5
0
6
0
7
0
8
5
1
0
0
1
2
0
X
-
O
V
E
R
|
H
z
P
H
A
S
E
|
Ø
°
-
1
0
-
9
.
5
-
8
.
5
-
6
.
7
-
5
.
2
-
4
.
2
-
3
.
2
-
2
.
3
-
1
.
5
-
0
.
5
0
1
.
0
1
.
6
2
.
5
3
.
5
4
.
5
5
.
5
6
.
7
8
.
0
9
.
5
1
0
VU
120
6
Var
-180°
Var
Off
LOW PHASE Control
20
LOW Section Setup
Choose the LOW crossover frequency (Linkwitz Riley low pass lter) with the LOW X-OVER switch: , , , ,  or Hz. The roll-o is  dB/octave.
Use the PHASE switch and the PHASE control to shi the LOW signal phase from
-° to +° for phase aligning subwoofer and main speaker positions.
If you switch the LOW Mono/Stereo Switch to Mono – both LOW Outputs L and R feed a LOW mono signal.
The output level of the subwoofer can be varied from -dB to +dB with the LOW Level control.
MID-HI Section Setup
Choose a MID-HI crossover frequency (Linkwitz Riley high pass lter) with the MID-HI X-OVER switch: , , , ,  or Hz.
Select the roll-o with the ROLL-OFF Switch:  or  dB/octave.
Normally the crossover frequency is equal to the LOW setting.
The MID-HI crossover can be disabled with the MID-HI X-OVER On/O switch in case the top speakers shall operate full range.
Basic Controls
The Crossover is equiped with a Hz low cut lter. If on (Hz) the input signal is ltered below Hz by dB/octave for both frequency ranges – LOW and MID-HI.
With the VU meter sensitivity switch you can lower the displayed VU levels by  or dB in case you are running hot signal levels.
You can select the VU meter source: the LOW frequency range, the MID-HI frequency range or the input signal.
19
20
21
22
23
24
25
26
27
28
LOW X-OVER Switch
LOW Level Control
LOW Mono/Stereo Switch
LOW PHASE Switch
20
19
22
21
VOLTAiR
120V DC Audio Rail
ON
LOW CUT
StereoMono
2412
PHASE
LOW MID-HI
5
0
6
0
7
0
8
5
1
0
0
1
2
0
ROLL-OFF
| dB
Crossover
X-OVER
OUT
20HzOffOnOff
VU
MID-HILOW
Input
Active Crossover
0
1
8
0
L
O
W
L
E
V
E
L
|
d
B
X
-
O
V
E
R
|
H
z
5
0
6
0
7
0
8
5
1
0
0
1
2
0
X
-
O
V
E
R
|
H
z
P
H
A
S
E
|
Ø
°
-
1
0
-
9
.
5
-
8
.
5
-
6
.
7
-
5
.
2
-
4
.
2
-
3
.
2
-
2
.
3
-
1
.
5
-
0
.
5
0
1
.
0
1
.
6
2
.
5
3
.
5
4
.
5
5
.
5
6
.
7
8
.
0
9
.
5
1
0
VU
120
6
Var
-180°
Var
Off
MID-HI X-OVER Switch
MID-HI ROLL OFF Switch
24
23
MID-HI X-OVER On/O Switch
25
EN
DE
LOW CUT
26
VU Meter Input Switch
28
VU Meter Sensitivity
27
Loading...
+ 7 hidden pages