Assembly
Connect the 1/8” NPT to an air supply between 80 and 90 PSI.
Cylinder life can be lengthened by using a commercial air line mist lubricator.
Lubrication
Tool Maintenance
The MK9P tool has been designed to require no maintenance by the operator.
Nosepiece
Soft Trigger
Swivel Hook
Soft Grip
1/8” NPT Male Air Supply Connector
Cam Knob (cable tie selection)
Fine Adjust Knob (cable tie tension adjustment)
Troubleshooting
Problem
Probable Cause Solution
Tool will not operate.
Will not cut cable tie.
Cable tie is breaking when applied.
Tool rod won’t return
to forward position.
Poor cutting action.
Check air supply connection to be sure tool is receiving air.
Check air supply regulator for proper adjustment.Increase pressure if necessary.
Release trigger and squeeze again.
Install Blade.
Check the 2 selector knobs for proper setting for cable tie being applied.
Depress and hold trigger while removing materials from nose area.
Replace blade (See page 3).
Re-install blade.
No air pressure.
Low air pressure.
Tool has reached end of stroke.
Blade missing.
Tension setting too high.
Material wedged in nose area.
Dull or damaged Blade.
Blade installed backwards.
MK9P (lower air connection) shown
HellermannTyton Canada
Phone: (905) 882-8024, (800) 661-2461 Fax: (905) 882-1624, (800) 390-3904 Email: sales@hellermanntyton.ca
HellermannTyton Mexico
Phone: (33-3) 659-7020, 011-52-33-3-659-7020 (From U.S.) Fax: (33-3) 659-6939 Email: info@hellermanntyton.com.mx
HellermannTyton North American Corporate Headquarters
7930 N. Faulkner Rd, PO Box 245017 Milwaukee, WI 53224 Phone: (414) 355-1130, (800) 537-1512 Fax: (414) 355-7341, (800) 848-9866 Email: corp@htamericas.com
A QS9000 & ISO 14001 Registered Company
www.hellermann.tyton.com
© HellermannTyton Corporation INSTMK9P — January 2005 — Printed in the U.S.A.
To replace blade - Follow Steps 1-3 and reassemble.
-+
- +
Operating Instructions - 1 2 3
Adjustment Instructions - A B C
1
2
3
A
B
C
.19” (2.5mm) .50” (12.7mm)
1-4 5-8
View from top of tool
MK9PUA (upper air connection) shown
A
width of cable tie
B
cable tie selection
C
tension adjustment
Blade Replacement - Removal of Tie Ejector
Tension Adjustment Lock - Move screw to desired position
Step 1
Step 2
Step 3
Note blade orientation
Blade Part # MK9P-109
UNLOCKED
Factory setting
LOCKED
Fine adjustment tension knob
Rotate set screw clockwise to lock cam knob