Spire SP-ATX-650WTB-PFC-1 User Manual

APPROVAL SHEET
Power supply
MODEL NO: SP-ATX-650WTB-PFC-1
ENGINEER NO: SUATX0450Z0ECPEU110
Audited by
Checked by
Drafted by
Spire Corp.
Tel.: +86-755-26801567 Fax: +86-755-26801561
Version:A/0
Http://www.spire-corp.com Http://www.spirepower.com Http://www.spirecoolers.com
Spire Corp.
Approval Sheet Revisement Record
Article No: SP-AP-SU-A093
Version
Description
Chapter
A/0 N/A First Version N/A
Revised
Revised
Date
Drafted
by
Audited
by
ECN
No.
Version:A/0 Page 2 of 18
Http://www.spirepower.com & Http://www.spirecoolers.com
Http://www.spire-corp.com
Spire Corp.
Contents
1 Introduction………………………………………………………………5
1.1 Scope………………………………………………………………………5
1.2 General Description………………………………………………….……5
2 Electrical………………………………………………………………………5
2.1 AC Input…………………………………………………..………………5
2.1.1 Input Over current Protection……………………………………5
2.1.2 Inrush Current Limiting…………………………….………………6
2.1.3 Withstand Voltage……………………………......……………...6
2.1.4 Catastrophic Failure Protection……………………….…………..6
2.2 DC Output……………………………………………………….…………6
2.2.1 DC Voltage Regulation……………….……………………………6
2.2.2 Output DC Current Ranges……….………………………………7
2.2.3 Output Voltage Line Regulation. ………………..………….….…7
2.2.4 Cross Regulation…………………………………..……………….7
2.2.5 Efficiency ………………………………………………..................7
2.2.6 Output Ripple/Noise………………………………………………..8
2.2.7 Output Transient Response…………...…………………………..9
2.2.8 Capacitive Load …………………………………………………….9
2.2.9 Closed-loop Stability ……………………………………………….9
2.2.10 Power Sequencing………………………………………………...9
2.2.11 Voltage Hold-up Time…………………………………..………10
2.3 Timing / Housekeeping / Control…………………….…………………..10
2.3.1 PWR_OK……………………………………….…………………10
2.3.2 PS_ON#…………………………………………………..………11
2.3.3 +5VSB……………………..……………….……………….……11
2.3.4 Power-on Time…………………………………...………………11
2.3.5 Rise time………………………………………………………..…11
2.3.6 Overshoot at Turn-on /Turn-off…………………………..………11
2.3.7 Reset after Shutdown……………………………………………11
Version:A/0 Page 3 of 18
Http://www.spirepower.com & Http://www.spirecoolers.com
Http://www.spire-corp.com
Spire Corp.
2.4 Output Protection…………………………………………………………12
2.4.1 Over voltage Protection…………………………………………12
2.4.2 Over Current Protection…………………………………………12
2.4.3 Short-circuit Protection……………………………………………12
3 Mechanical……………………………………………………..……………12
3.1 AC Connector. ………………………………..…………………………12
3.2 DC Connector Pin Description…………………….……..……………13
4 Environmental…………………………..……………………………………14
4.1 Environmental (Operating)…………………..…………………………14
4.2 Environmental (Non-Operating)…………..……………………………14
5 Electromagnetic Compatibility…………………………..…………………14
5.1 EMI…………………………………………………..……………………14
6 Reliability……………………………………………………………………15
6.1 Component Derating………………………………………..……………..15
6.2 Mean Time Between Failures(MTBF)…………………..……………15
7 Correlative Certification compliance…………………………………..…………15
8 Connectors& cables diagram ……………………………………………16
9 Photograph …………………………………………………..…………………17
Version:A/0 Page 4 of 18
Http://www.spirepower.com & Http://www.spirecoolers.com
Http://www.spire-corp.com
1 Introduction
1.1 Scope
This specification defines the performance and characteristic for the model of
SP-ATX-650WTB-PFC-1 power supply.
1.2 General Description
SP-ATX-650WTB-PFC-1 is a switching power supply, 650W self-contained, AC to
DC power source supply suitable for mounting in PC.
1) SPCC 0.8MM ENCLOSURE
2) ONE 12CM FAN
3) Black Paint Case
4) Dimensions:140mm(L)X150mm(W)X85mm(H)
2 Electrical
Spire Corp.
2.1 AC Input
Table 1 list AC input voltage and frequency requirements for continuous operation.
Power Factor Correction (PFC)
SP-ATX-650WTB-PFC-1 (w/ Passive PFC) is facilitated with the universal input
200~240VAC Passive PFC with the PF value 0.65 ≧≦0.8
2.1.1 Input Over Current Protection
Parameter Min. Nom.
Vin Voltage 198 220-230 253
Vin Frequency 50 --- 60 Hzrms
(1)
Nominal voltages for test purposes are considered to be within ±1.0 V of nominal.
Table 1. AC Input Line Requirements
(1)
Max. Unit
The power supply is equipped with a non-reset-able fuse on the AC
input to limit power consumption on a failure within the power supply
module.
VACrm s
Input Fuse Rating:
Voltage 250 V
Current 6.3A
De-activation time 200 ms
Version:A/0 Page 5 of 18
Http://www.spirepower.com & Http://www.spirecoolers.com
Http://www.spire-corp.com
Spire Corp.
2.1.2 Inrush Current Limiting
Maximum inrush current from power-on (with power on at any point on the AC sine) and including, but not limited to, three line cycles, shall be limited to a level below the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not damage the power supply or cause the input fuse to blow.
2.1.3 Withstand Voltage
The power supply is capable of withstanding a maximum 1500 VDC
potential between the input and ground for a period of 1 second.
2.1.4 Catastrophic Failure Protection
If a component failure occurs, the power supply will not exhibit any of
the following:
1) Flame
2) Excessive smoke
3) Charred PCB
4) Fused PCB conductor
5) Startling noise
6) Emission of molten material
2.2 DC Output
2.2.1 DC Voltage Regulation
The DC output voltages are remain within the regulation ranges shown in Table
2 when measured at the load end of the output connectors under all line, Load,
and environmental conditions.
Table 2. DC Input Line Requirements
Output Range Min. Nom.(1) Max. Unit
+12V1DC ± 5% +11.40 +12.00 +12.60
+12V2DC ± 5% +11.40 +12.00 +12.60
+5VDC ± 5% +4.75 +5.00 +5.25
+3.3VDC ± 5% +3.14 +3.30 +3.47 Volts
Volts
Volts
Volts
-12VDC ± 10% -10.80 -12.00 -13.20
+5VSB ± 5% +4.75 +5.00 +5.25
1) ATX +12VDC peak loading, regulation at the + 12Vdc output can go to±10%.
Version:A/0 Page 6 of 18
Http://www.spirepower.com & Http://www.spirecoolers.com
Http://www.spire-corp.com
Volts
Volts
Loading...