A safe operation of SENSILEVEL products is assured when they are properly installed, commissioned,
used and maintained by qualied personnel according to the operation instructions (see section
11 of present instruction paper). Compliance with installation and safety general instructions must
also be observed during piping and plant erection together to an appropriate use of equipment and
facilities for safety.
Note: products supplied by Spirax Sarco are classied as components and, it general, they
aren't subjected to the European Machinery Directive 2006/42/EC.
1.1 Type of Application
The suitability of Sensilevel has to be veried for the specic usage and application according to
product tag and technical specications and to installation and maintenance instructions. The products
of the below indicated list comply with the requirements of the European Directive 2014/68/EU
(Pressure Equipment Directive - PED) and are marked. They pertain to the following categories
of the Pressure Equipment Directive.
Product
Gas / Liquid
Group 1 e 2
2202A - 2202B 2
2206A - 2207A 2
2206B - 2207B - 2207C - 2207D 3
I) Products have been specically designed for hazardous and not hazardous uids that are
included in Group 1 and 2 of the above mentioned European Directive.
II) Verify suitability of material and the minimum and maximum values of pressure and temperature.
If the maximum operating limit conditions of the product are lower than those of the system
where it has to be used or if an improper operation of the product might cause a dangerous
excess of pressure and temperature, make sure to include in the system a safety device to
prevent limits overcoming.
III) Determine the correct position of the installation and the ow direction of the uid.
IV) Our products cannot cope with external stress induced by the system in which they operate.
The installer is responsible of stress analysis and of adequate precautions to be taken in order
to minimize the external stress.
V) Remove protective covers from all connections prior to installation.
1.2 Accessibility
Ensure safe access and, if necessary, a work platform before starting to work on the product. Use
suitable lifting mechanisms as necessary.
1.3 Lighting
Ensure sufcient lighting, particularly where detailed work or work in poorly accessible areas is required.
1.4 Dangerous gases or liquids present in the pipeline
Take account of pipeline content or what it may have recently contained. Pay attention to: inammable
materials, substances dangerous to health, temperature extremes.
1.5 Dangerous environmental situations and area
Take account of areas at risk of explosion, lack of oxygen (e.g. tanks or pits), dangerous gases,
temperature extremes, hot surfaces, re hazard (e.g. during welding), excessive noise, moving
machinery.
These products comply with the requirements of the European Directive 2014/34/EU (ATEX) for
the use of equipments in potentially explosive atmospheres.
In a classied area do not access the housing when powered and do not use tools that could
cause sparks.