Spiegelberg IAP 32.1, IAP-Monitor Operating Instructions Manual

Spiegelberg:
IAP-Monitor IAP 32.1
Operating-Instructions
Manufacturer
SpiegelbergSpiegelberg
SpiegelbergSpiegelberg
Spiegelberg (GmbH & Co.) KG(GmbH & Co.) KG
(GmbH & Co.) KG TT
TT
T
empowerkring 4empowerkring 4
empowerkring 4empowerkring 4
empowerkring 4
21079 Hamburg21079 Hamburg
21079 Hamburg21079 Hamburg
21079 Hamburg GermanyGermany
GermanyGermany
Germany
Phone:Phone:
Phone:Phone:
Phone:
+49-40-790-178-0+49-40-790-178-0
+49-40-790-178-0+49-40-790-178-0
+49-40-790-178-0
Fax:Fax:
Fax:Fax:
Fax:
+49-40-790-178-10+49-40-790-178-10
+49-40-790-178-10+49-40-790-178-10
+49-40-790-178-10
Email:Email:
Email:Email:
Email:
info@spiegelberg.deinfo@spiegelberg.de
info@spiegelberg.deinfo@spiegelberg.de
info@spiegelberg.de
http://wwwhttp://www
http://wwwhttp://www
http://www
.spiegelberg.de.spiegelberg.de
.spiegelberg.de.spiegelberg.de
.spiegelberg.de
BEDIAP32.1.91 V 2.0 © by Spiegelberg (GmbH & Co.) KG, 2003
Innovative Measurement Technology for Medicine
0297
CE-marking according to directive 93/42/EEC
Technical alterations reserved.
Pinout of DB 9 Socket
1: Uref Input 2: RxD 3: TxD 4: 5: Analog Output
For use as a voltage output pins 1 and 6 are connected by a jumper.
For use as a monitor output the excitation voltage is fed into the reference input and the analog output is scaled down by a resistive divider.
Data Transmission across the RS 232 C Interface
The IAP-Monitor responds to single ASCII bytes:
To the monitor
´A´
´B´
´C´
6: Uref Output (2,5 V) 7: Digital Gnd 8: 9: Analog Gnd.
Response
Mean pressure in ASCII string format, terminated by ´Carriage Return´.
Mean pressure in binary format, 1/10 mm Hg resolution, two´s complement, two bytes, high byte first.
Instantaneous pressure in binary format, 1/10 mm Hg resolution, two´s complement, two bytes, high byte first. Response only after new value is read in (every 10 ms).
9 2
Contents
Safety instructions Indication and Method Monitor Operation Cleaning Connections Faults Technical Specifications Accessories
2 3 4 5 6 7 8
10
Safety Instructions
The IAP-Monitor and the accom­panying catheters are designed for the measurement of intraabdominal pressure. The manufacturer accepts responsibility for the safety, reliability and performance of the monitor only if:
- the installation, extensions, readjustments, modifications and repairs are performed by authorized personnel,
- the electric installation of the room is in accordance with the national regulations concerning rooms used for medical purposes,
- the monitor is used in accordance with the operating instructions, and
- the monitor is used with the approved accessories.
WW
WW
W
arningarning
arningarning
arning
The device is not intended for use in areas where there is a danger of explosion.
WW
WW
W
arningarning
arningarning
arning
The device may be repaired only by persons or companies that are authorized to do so.
WW
WW
W
arningarning
arningarning
arning
The device is not intended for use during Electro­Surgery/Diathermy.
WW
WW
W
arningarning
arningarning
arning
Grounding reliability can only be achieved if the device is connected to an equivalent power cord marked „hospital grade“ or „hospital only“.
Loading...