OPERATING INSTRUCTIONS
Form # 379 4/06
MODEL: ET6207
LONG LEAD 4-RANGE VOLTAGECONTINUITY TESTER
BEFORE USE:
READ ALL OPERATING INSTRUCTIONS BEFORE USE. Use extreme caution when checking
electrical circuits to avoid injury due to electrical shock. Sperry Instruments assumes basic
knowledge of electricity on the part of the user and is not responsible for any injury or
damages due to improper use of this tester.
OBSERVE and follow all standard industry safety rules and local electrical codes. When
necessary call a qualified electrician to troubleshoot and repair the defective electrical circuit.
SPECIFICATIONS:
Operating Range: 80-480 VAC/DC, 60 Hz; CAT III 600V
Indicators: Visual Only
Operating Environment: 32° - 104° F (0 - 32° C)
Altitude up to 2000 meters. Indoor use.
Pollution degree 2. Accordance with IED-664.
Cleaning: R
emove grease and grime with clean, dry cloth.
80% RH max., 50% RH above 30° C
OPERATION:
To test for voltage insert test leads into outlet or carefully touch test leads to electrical
contacts or circuit to be tested. If voltage is present the neon indicators in the correct range
will glow. Use the highest illuminated range for the correct voltage. The brightness of the
bulbs will increase as the voltage increases.
To test for the live side of an electrical outlet insert one probe into the ground plug of the
outlet while inserting the other probe in the alternate sides of the outlet. The neon
indicator(s) will glow when the probe makes contact with the live side.
SINGLE HAND OPERATION:
Sperry’s unique design allows for convenient single hand testing of outlets when the probes
are secured side-by-side on the tester housing. Just insert the probes into the outlet and if
voltage is present the neon indicator(s) will glow.
To test for continuity just place the probe tips on the circuit to be tested.
If continuity (continuous circuit with no br
light.
Batteries: This tester requires two 1.5 Volt button cell batteries (LR44, SR44, A76, G13,
AG13, GP76A, 257, D357, V13GA) for the continuity function. To test if the batteries are
good and the continuity test function is operating properly touch the two test leads together.
If the continuity indicator does not light then replace the batteries by r
cover on the back of the tester.
eaks) is present the continuity indicator LED will
emoving the battery
CAUTION – REFER TO THIS MANUAL BEFORE USING THIS
TESTER.
Double Insulation: The tester is protected throughout by double insulation or
reinforced insulation.
Test Equipment Depot - 800.517.8431 -
99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com
©2006 SPERRY INSTRUMENTS, INC.