Sperry instruments CS500A User Manual

Page 1
12/03 Form #414
MODEL CS500A
CIRCUIT BREAKER FINDER
The job of locating electrical circuits (AC circuits of 110
- 125 volts) is now made quick and easy. No more guessing or trial and error when it comes to locating the correct circuit breaker or fuse supplying electrical power to an outlet or lighting fixture.
WARNING: Always check that the Circuit Breaker Finder battery and unit are operating properly before proceeding.
PREPARING TO USE THE CIRCUIT BREAKER FINDER: BATTERY INSTALLATION
1. Remove battery cover.
2. Connect 9V battery as shown in Fig. 1.
We recommend environmentally safe ‘Green’ batteries.
3. Insert connected battery into battery compartment.
4. Re-install battery cover. UNIT TEST
1. Plug transmitter into electrical wall outlet with the
power on.
2. Turn receiver on just until click is heard and the LED lights. This is the maximum sensitivity setting.
3. Place receiver near transmitter as shown in Fig. 2. If receiver is working and the wall outlet’s power is on, the receiver will produce a distinctive beep at approximately 6 times per second and the LED will flash.
USING THE CIRCUIT BREAKER FINDER: LOCATING CIRCUIT BREAKER OR FUSE
CONTROLLING A WALL OUTLET
1.
Plug transmitter into a wall outlet with the power on.
2. Check unit as in “Unit Test” section.
Nota: en ciertos casos,
o
4.906.938
Fig.1
Fig.2
Fig.3
. 1
1788
®
Page 2
12/03 Brochure n° 414
MODÉLE CS500A
CHERCHEUR DE DISJONCTEUR
La tâche de localiser les circuits électriques (circuits CA de 110 à 125V) est maintenant rapide et facile. Plus de devinettes ni de tâtonnements lorsqu’il s’agit de localiser le bon disjoncteur ou fusible qui fournit l’alimentation électrique à une prise de courant ou à un appareil d’éclairage.
AVERTISSEMENT: Toujours s’assurer que la pile et l’unité du chercheur de disjoncteur fonctionment correctement avant de commencer.
PRÉPARATION DU CHERCHEUR DE DISJONCTEUR POUR UTILISATION: INSTALLATION DE LA PILE
1. Enlever le couvercie de pile.
2. Brancher la pile de 9 V tel que montré à la
figure 1. Nous recommandons les piles “vertes” sans danger pour l’environnement.
3. Insérer la pile branchée dans le logement de pile.
4. Remettre en place le couvercle de pile. ESSAI DE L’UNITÉ
1. Brancher l’émetteur dans une prise murale
électrique sous tension.
2. Mettre le récepteur sous tension jusqu’à ce qu’un déclic se fasse entendre et que le voyant DEL s’allume. Il s’agit là du réglage maximal de sensibilité.
3. Placer le récepteur près de l’émetteur tel que montré à la figure 2. Si le récepteur fonctionne et que la prise murale est sous tension, le récepteur fera entendre un bip distinctif environ 6 fois par sec onde et le voyant DEL clignotera.
UTILISATION DU CHERCHEUR DE DISJONCTEUR: LOCALISATION D’UN DISJONCTEUR OU D’UN
FUSIBLE COMMANDANT UNE PRISE MURALE
1. Brancher l’émetteur dans une prise murale
sous tension.
2. Vérifier l’appareil en suivant la section sur l’essai de l’unité.
3. Go to circuit breaker panel box and place flat surface of tapered end of receiver at a right angle and directly on circuit breaker or fuse, as shown in Fig. 3.
4. Slowly move receiver up and down over the row or rows of circuit breakers or fuses while continually lowering the receiver’s sensitivity by rotating the wheel away from the panel box until only one (1) breaker or fuse causes the receiver to beep. (Note: In certain instances an adjacent breaker or fuse may cause a beep due to the routing of the wires in the panel.)
5. After you have located the right breaker or fuse, you can turn off the circuit and the receiver will stop beeping.
6. Check that the red light on the transmitter in the outlet is off to confirm you have turned off the correct breaker or fuse.
OUTLETS CONTROLLED BY WALL SWITCH
1. Your Circuit Breaker Finder is the easiest way to determine if a wall outlet is controlled by a wall switch.
2. Simply turn the wall switch OFF.
3. Plug the transmitter into the outlet being tested.
4. Repeat the Unit Test.
5. If the receiver does not beep, that portion of the outlet is controlled by the wall switch.
CAUTION: Use extreme care when you work around electric circuits. Asevere shock hazard exists. Your Circuit Breaker Finder is not intended to replace good electrical practices, but to assist you in knowing how your home or workplace is wired.
LIMITED ONE YEAR WARRANTY
Made from recycled paper.
Patent No. 4,906,938
MADE IN CHINA
3. Aller à la boîte du panneau de disjoncteurs et placer
4. Déplacer lentement le récepteur vers le haut et vers
5. Après avoir localisé le bon disjoncteur ou fisuble,
6. S’assurer que le témoin rouge sur l’émetteur dans
PRISES DE COURANT COMMANDÉES PAR UN INTERRUPTEUR MURAL
1. Le chercheur de disjoncteur offre la façon la plus
2. Mettre simplement la prise murale à la position
3. Brancher l’émetteur dans la prise à l’essai.
4. Reprendre l’essai de l’unité.
5. Si le récepteur ne fait pas entendre de bip,
MISE EN GARDE: Prendre des précautions extrêmes
lorsqu’on travaille à proximité de circuits électriques. Il existe un risque de choc électrique grave. Le chercheur de disjoncteur n’est pas conçu pour remplacer les bonnes pratiques en électricité, mais pour aider à connaître la manière une maison ou un lieu de travail est câblé.
2150 Joshua’s Path, Suite 302, Hauppauge, N.Y. 11788
1-800-645-5398 • 1-631-231-7050
Fax: 1-631-434-3128
Fig.1
Fig.2
Fig.3
A.W. SPERRY INSTRUMENTS INC.
The Professional’s Choice
®