for Air Purifying Respirator (APR), Continuous Flow Supplied Air Respirator
(CF–SAR), and Powered Air Purifying Respirator (PAPR) Congurations
Air Purifying Respirator
Front Adapter Cap
Air Purifying Respirator
Low Prole Nozzle Plug
CF-Supplied Air Respirator
Side-mount Breathing Tube
SURVIVAIR Opti-Fit
™
Convertible Facepiece
CF-Supplied Air Respirator
Front-mount Breathing Tube
Powered Air Purifying
Respirator Mask-mount Blower
Powered Air Purifying
Respirator Belt-mount Blower
CF-Supplied Air Respirator
P100 Filter Escape
DO NOT USE your respirator until you read and completely understand this
instruction manual. You are required to inspect the adapter prior to putting it
into service. Please refer to the inspection procedures in this manual. Failure
to comply with this warning may result in personal injury, illness, or death.
Copyright SPERIAN Respiratory Protection USA, LLC
April 2008 All Rights Reserved
P/N 764099 REV D 03/09
WARNING
AN ISO 9001
REGISTERED
COMPANY
SPERIAN Respiratory Protection USA, LLC
3001 South Susan St., Santa Ana, CA 92704
Toll-Free 888.APR.SCBA or 714.545.0410
Fax 714.850.0299
www.sperianprotection.com
NIOSH APPROVAL CAUTIONS AND LIMITATIONS
The Cautions and Limitations applicable to the air purifying respirator (APR), continuous ow supplied air respirator
(CF-SAR), and powered air purifying respirator (PAPR) congurations are listed below:
Operating CongurationCautions and Limitations
Air Purifying Respirator (APR)ABCHJLMNOPS
Continuous Flow Supplied Air Respirator (SAR)ABCDEGHJLMNOPS
Powered Air Purifying Respirator (PAPR)ABCFHIJLMNOPS
Cautions and Limitations Key:
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
D - Air line respirators can be used only when the respirators are supplied with respirable air meeting the requirements
of CGA G-7.1 Grade D or higher quality.
E - Use only the pressure ranges and hose lengths specied in the User’s Instructions.
F - Do not use respirator if airow is less than four cfm (115 lpm) for tight tting facepieces or six cfm (170 lpm) for hoods
and/or helmet.
G - If airow is cut off, switch to lter and/or cartridge and immediately exit to clean air.
H - Follow established cartridge and canister change schedules or observe ESLI to ensure that cartridges and canisters
are replaced before breakthrough occurs.
I - Contains electrical parts which have not been evaluated as an ignition source in ammable or explosive atmospheres
by MSHA/NIOSH.
J - Failure to properly use and maintain this product could result in injury or death.
L - Follow the User’s Instructions for changing cartridges, canisters and/or lters.
M - All approved respirators shall be selected, tted, used, and maintained in accordance with MSHA, OSHA, and other
applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the conguration as specied by
the manufacturer.
O - Refer to Users Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
S - Special or critical User’s Instructions and/or specic use limitations apply. Refer to User’s Instructions before donning.
i
SURVIVAIR Opti-Fit™ Convertible Facepiece
TABLE OF CONTENTS
NIOSH APPROVAL CAUTIONS AND LIMITATIONS ....................................................i
TABLE OF CONTENTS .........................................................................ii
I. INTRODUCTION.............................................................................1
II. SAFETY PRECAUTIONS......................................................................1
III. DESCRIPTIONS OF RESPIRATOR OPERATING CONFIGURATIONS .................................1
A. Air Purifying Respirator (APR) Conguration ...................................................1
B. Supplied Air Respirator (CF-SAR) Conguration ................................................1
C. Powered Air Purifying Respirator (PAPR) Conguration ...........................................2
IV. General Warnings for All Respirator Congurations .................................................2
V. RESPIRATOR OPERATING CONFIGURATIONS SCHEMATIC ........................................5
VI. PARTS LIST ...............................................................................6
Table 1. Air Purifying Respirator (APR) Filters and Cartridges ........................................8
Table 2. Continuous Flow Supplied Air Respirator (CF-SAR) Air Hose Components .......................8
Table 3. Powered Air Purifying Respirator (PAPR) Belt-Mounted Cartridges .............................8
VII. FACEPIECE PREPARATION USING INCLUDED ITEMS............................................9
VIII. OPERATING INSTRUCTIONS FOR SPECIFIC RESPIRATOR CONFIGURATIONS .....................10
A. Air Purifying Respirator (APR) Conguration ..................................................10
1. Installing Chemical Cartridges and Particulate Filters ......................................... 11
2. Donning Instructions for APR Conguration.................................................12
3. Fit Check Instructions for APR Conguration ................................................13
4. How to Use the Respirator ..............................................................13
5. Dofng Instructions for APR Conguration..................................................13
6. Chemical and Particulate Filter Service Life and Replacement ..................................13
B. Continuous Flow Supplied Air Respirator (CF-SAR) Congurations.................................15
1. Air Supply ...........................................................................16
This manual provides instructions for the use and maintenance of the various respirator operating congurations achievable with the SURVIVAIR Opti-Fit™ Convertible full facepiece respirator models 7540, 7640, 7740,
7541, 7641, and 7741. The base conguration of the
SURVIVAIR Opti-Fit facepiece allows use as an air purifying respirator (APR) in conjunction with S Series par-
ticulate lters, gas and vapor cartridges, and cartridge/
lter combinations as required for specic contaminant
protection. Additional components can be attached to
the SURVIVAIR Opti-Fit Convertible to easily convert it
to a front or side hose connection continuous ow supplied air respirator (CF-SAR) and mask or belt mounted
powered air purifying respirator (PAPR) congurations.
Before using a respirator in a contaminated work
place, you must, at a minimum, understand the elements of a respirator program, your work place, and
the contaminants you are trying to protect yourself
against. Determining the applicability of a respirator
is difcult. You must be able to calculate the service
life of the cartridges, determine the type and concentration of contaminants, and determine whether
the contaminants have poor warning properties,
etc. If you do not have a complete understanding
of the use of respirators, you must seek the aid of
a certied industrial hygienist or contact SPERIAN.
You must read and understand this manual and be
trained in the proper use of the respirator before
wearing it in a contaminated atmosphere.
II. SAFETY PRECAUTIONS
The Warnings, Cautions, and Notes contained in this
instruction sheet have the following signicance
WARNING
Maintenance or operating procedures
and techniques that may result in serious personal injury, serious personal illness, or death if not carefully followed.
CAUTION
Maintenance or operating procedures and
techniques that may result in damage to
equipment and/or minor to moderate personal injury if not carefully followed.
NOTE
Maintenance or operating procedures and
techniques or information considered impor-
tant enough to emphasize.
III. DESCRIPTIONS OF RESPIRATOR OPERATING
CONFIGURATIONS
The SURVIVAIR Opti-Fit full facepiece contains two
connectors on each side of the lens for attaching par-
ticle lters, gas/vapor cartridges or air hoses, as well
as a front adapter for a supplied air breathing hose or
powered air purifying blower. This range of connections
allows the SURVIVAIR Opti-Fit Convertible facepiece
to be congured, through the use of additional components, as a supplied air respirator (CF-SAR) or powered
air purifying respirator (PAPR).
The full facepiece is designed with a wide lip silicone
skirt and ve point head strap harness (models 7540,
7640, and 7740). The facepiece is also available with
a Headnet™ retention system (models 7541, 7641, and
7741). All facepieces contain a lens treated with an
abrasion resistant coating. The facepiece is available
in three sizes, small, medium and large. While a nose
cup is standard, the facepiece may be equipped with an
optional spectacles kit, clear or tinted lens covers and
neck strap kit.
The connection versatility of the SURVIVAIR Opti-Fit™
Convertible full facepiece and available components and
accessories (see Section VI, Parts List) allow it to be as-
sembled into the following operating congurations:
A. Air Purifying Respirator (APR) Conguration
The side port connectors are used to attach S series
particulate lters, gas and vapor cartridges, and cartridge/lter combinations as required for a specic con-
taminant protection. The front adapter can be removed
and replaced with a plug to reduce the front prole of
the mask.
B.Continuous Flow Supplied Air Respirator
(CF-SAR) Conguration
With one side port connector port capped with a supplied screw cap, a high volume, low pressure breathing tube can be attached to the second side connector
to provide a constant ow of air to the facepiece when
connected to an external air source. An alternate connection option uses a breathing tube connected to the
front adapter with both side port connectors capped. An
optional Vortex air cooler may also be connected in-line
to provide cool air to the facepiece.
NOTE
The Vortex air cooler cannot be used in
conjunction with ambient air pump supply
systems.
The SURVIVAIR Opti-Fit™ Convertible can also be con-
gured as a CF-SAR with P100 lter cartridges and the
breathing tube connected to the front adapter. When the
air line hose is disconnected from the air line quick coupler, a check valve in the air line couple assembly prevents leakage of contaminated air through the facepiece
hose, and the wearer’s air is drawn through the P100
lters. This feature allows for safe entry, exit or escape
from a dangerous area in case of air supply failure.
For all CF-SAR congurations, when used at pressures
specied in the tables in Section VIII, Part B.8, air is de-
livered to the facepiece at a rate between 115 and 425
liters per minute (4-15 cubic feet per minute [cfm]).
1
SURVIVAIR Opti-Fit™ Convertible Facepiece
WARNING
The pressure within the full facepiece
continuous ow supplied air respirator
(CF-SAR) remains positive under most
working conditions, but as with all respirators, negative pressure excursions are
possible. Conditions when a respirator
can experience negative facepiece pressures include, but are not limited to:
1) the respirator is improperly worn,
2) the respirator is not used in accordance with the instructions, or
3) the respirator is over-breathed during
heavy work rates. The respirator will
provide reduced protection when operated in a negative pressure mode. Failure to comply with this warning may result in personal injury, illness, or death.
The ANSI Z88.2-1992 assigned protection factor (APF)
for full facepiece continuous ow atmosphere supplying respirators is 1000. An APF of 1000 means that this
device, when properly used, will reduce exposure by a
factor of 1000.
C. Powered Air Purifying Respirator (PAPR)
Conguration
The SURVIVAIR Opti-Fit™ Convertible full facepiece
can be congured into a mask-mounted or belt-mounted powered air purifying respirator. In the mask-mount-
ed conguration, a high efciency (HE) lter/blower
mounts directly to the nozzle of the facepiece and deliv-
ers air to the facepiece at a ow rate greater than 115
liters per minute (4 cubic feet per minute). The blower
is powered by a belt mounted rechargeable nickel cadmium battery pack equipped with an ON/OFF switch.
This conguration is NIOSH approved and SPERIAN
recommended for respiratory protection against dusts,
fumes and mists, including asbestos-containing dusts
and mists, particulate radionuclides, and radon daughters attached to dusts, fumes and mists.
The belt-mounted PAPR respirator uses the SURVIVAIR
Opti-Fit™ Convertible facepiece, a rubber breathing
tube, a belt mounted blower with three (3) cartridges or
lters and a rechargeable Nickel Cadmium (NiCad) battery pack. Filtered breathing air is provided to the face-
piece at a ow rate greater than 170 liters per minute
(6 cubic feet per minute). To maintain NIOSH approval,
only the equipment and accessories listed on the appropriate NIOSH approval label may be used together.
IV. GENERAL WARNINGS FOR ALL RESPIRATOR
CONFIGURATIONS
The following general warnings must be observed for
proper operation of all air purifying (APR), continuous
ow supplied air (CF-SAR) and powered air purifying
(PAPR) respirator congurations. Additional warnings for
specic operating congurations are listed in Section VIII,
Parts A, B, and C, and must also be observed for proper
operation of the respective respirator conguration.
General Warnings for All Respirator Congurations:
WARNING
● Your employer (or you, if you do not
have an employer) is responsible for
establishing that this respirator is
suitable for the user’s application.
● SPERIAN cannot predict what will
happen to this respirator in every potential environment. Materials can be
chemically attacked if exposed to the
wrong environment and may exhibit
excessive corrosion or other forms
of damage. Permeation or penetration
of gases, liquids or particles through
the materials could be excessive. Extremes of temperature might cause
thermal degradation. Each of these
things, or a combination of them, could
create conditions in which this respirator would be dangerous to use.
● Before entering a hazardous environment while wearing this respirator,
you must conduct safe, scientic
tests to determine if the environment
could render the equipment unsafe.
Results of this testing should be well
documented. Seek the help of a certi-
ed safety professional or industrial
hygienist. DO NOT USE this equipment if the user would be endangered
in any way through environmentally
induced degradation of the materials
in the apparatus.
● All persons using this SPERIAN
breathing apparatus must be made
aware of its limitations. We cannot
be responsible for any damage to
property, personal injury, or death in
which environmental exposure is a
contributing factor.
● Do not use this respirator if anything
comes between the facepiece and
your face (e.g., hair, bandanna, head
covering, etc.). This condition will
prevent a good facepiece seal and
may allow the leakage of contaminants into the facepiece.
● Do not use this respirator in environments where the concentrations of contaminants are unknown or are immediately dangerous to life or health (IDLH).
IDLH atmospheres are dened as:
a. Those that the wearer could not
breathe for short periods.
b. Those from which the wearer
could not escape without the aid
of a respirator.
c. Those which have an immediate or
delayed adverse effect on health.
● Do not use this respirator at ambient
temperatures above 130°F (55°C).
2
SURVIVAIR Opti-Fit™ Convertible Facepiece
WARNING─Continued
● Do not use this respirator where en-
vironmental conditions could cause
the respirator facepiece to be dislodged or slip.
● Immediately return to a non-contaminated area if:
You taste or smell contaminants, a.
or if your eyes, nose, or throat
become irritated.
Breathing becomes difcult.b.
The air you are breathing be-c.
comes uncomfortably warm.
You feel nauseous or dizzy.d.
You notice a loss or decrease in e.
airow.
The facepiece moves, slips, or f.
leaks.
● This respirator does not protect exposed areas of the body. Some contaminants can be absorbed directly
through the skin while others may
irritate exposed areas.
● This respirator does not provide protection from hazardous rays or harm-
ful noise. Always wear proper head
and ear protection.
● This respirator must not be used
underwater, for fumigation, interior structural fire fighting, abrasive
blasting operations, or in areas where
high heat, sparks, or flames could
contact the respirator. If this respirator will be used during welding, it
is the user’s responsibility to obtain
the proper equipment for protection
against sparks, optical radiation, and
impact. This respirator will not pro-
tect you against these hazards.
● This respirator must be used in con-
junction with a written respirator
program meeting the requirements
of the OSHA Standard for Respiratory Protection, 29 CFR 1910.134,
available from the U.S. Department
of Labor, Occupational Safety and
Health Administration. The program
must include procedures for evaluating air contaminants and selecting
appropriate respirators; procedures
for proper use of respirators; procedures for testing the facepiece fit of
respirators; procedures for cleaning,
disinfecting, inspecting, maintaining,
and storing respirators; procedures
for determining if workers are physically and medically capable of wearing respirators; and procedures for
training employees in the use and
care of respirators and in recognizing the hazards associated with con-
taminants in the work place.
WARNING─Continued
● Do not wear this respirator if a satis-
factory fit, as determined by a qualitative or quantitative fit test, cannot
be obtained. See ANSI Z88.2, latest
issue, and OSHA 29 CFR 1910.134,
latest edition. Beards, stubble, or
sideburns will prevent a good facepiece seal, and facial hair may interfere with valve function. Do not use
this respirator unless you are clean
shaven. Absence of one or both dentures can seriously affect the fit of
the respirator.
● This respirator will reduce, but will
not eliminate the inhalation of contaminants. Some sensitive individuals may experience health problems when exposed to even minute
amounts of contaminants. This respirator will not prevent health problems to those individuals.
● Use of components other than those
listed on the NIOSH approval label
and in this manual, or as authorized
by SPERIAN, or modification of this
respirator in any manner will void
the NIOSH certification and invalidates all SPERIAN’s warranties for
the respirator.
● Always read and follow the instructions listed in the Material Safety
Data Sheet for the chemicals that are
present in the work area.
● Do not use if you have a preexisting
skin condition (for example, folliculitus or vitiligo) until you obtain clearance from a medical doctor.
● This respirator must be worn and
used as specified in SPERIAN’s instructions. No respirator can provide complete protection from all
conditions. Use extreme care for
emergency conditions.
● Some individuals are sensitive to
chemicals (e.g., isocyanates, latex,
oil mists, etc.) or may have some
type of respiratory disorder (e.g.
asthma, chronic obstructive airway
disease, etc.). If you are sensitive to
any chemical or have a respiratory
disorder, you may have a severe reaction at contaminant levels well below
accepted health levels, such as the
OSHA Permissible Exposure Limit
(PEL), ACGIH Threshold Limit Value
(TLV), or the NIOSH Recommended
Exposure Limits (REL). Many chemicals (e.g., isocyanates, Mercury, etc.)
have no physical warning properties
and you cannot taste or smell the
contaminants even though they may
3
SURVIVAIR Opti-Fit™ Convertible Facepiece
WARNING─Continued
be present in the respirator facepiece. This respirator will reduce, but
will not eliminate the possibility of
contaminants entering the facepiece
and causing a severe reaction. Do not
use this respirator until you obtain
clearance from a medical doctor.
● Users must clean and maintain this
respirator only in accordance with
SPERIAN’s instructions. Accessories
not offered by SPERIAN may degrade
performance, and will void NIOSH
certification.
● The respirator facepiece assembly
contains natural rubber latex, which
may cause allergic reactions in some
individuals. Discontinue use if you
experience an allergic reaction.
● Discontinue use if you experience
skin irritation or discoloration.
● This product may provide less than
adequate protection if improperly
used, which may result in personal
injury, illness, or death.
● For use by trained, qualified personnel
only.
● Do not use this respirator if it has
been left exposed in a contaminated
environment as contaminants could
collect on the inside of the facepiece
and be inhaled when the gas mask is
donned.
● Routinely used respirators must be
inspected before and after each use.
Stored emergency respirators must
be inspected after each use and at
least every 30 days. A written record
must be kept of emergency respirator inspections.
FAILURE TO OBSERVE ALL WARNINGS MAY RESULT IN PERSONAL INJURY, ILLNESS, OR DEATH.
4
SURVIVAIR Opti-Fit™ Convertible Facepiece
V. RESPIRATOR OPERATING CONFIGURATIONS SCHEMATIC
Cartridges and
Filters See
cartridge table
in Section VI
for available
cartridge part
numbers.
Side-mount
Tube and Belt
Kits*:
Light Duty
P/N 981415
Heavy Duty
P/N 981416
SURVIVAIR Opti-Fit
Convertible Facepiece
5-Pt. Strap
Small/Medium/Large
754000/764000/774000
Mesh Headnet
Small/Medium/Large
754100/764100/774100
™
APR
Air Purifying
Respirator (APR)
SURVIVAIR Opti-Fit
Facepiece
Side-mount Tube
CF-Supplied Air
Respirator (CF-SAR)
PAPR
CF-SAR
Front- mount
Tube and
Screw Caps
Kit*:
P/N 981205
Front- mount
Tube and P100
Filters
Kit*:
981209
Mask- mount
PAPR
Kit
520075
SURVIVAIR Opti-Fit
Facepiece Front-
mount Tube CF-SAR
5-Pt. Strap S/M/L
981500/981501/981503
Mesh Headnet™ S/M/L
981550/981551/981553
SURVIVAIR
Opti-Fit Facepiece
P100 Escape
CF-Supplied Air
Respirator (CF-SAR)
SURVIVAIR Opti-Fit
Facepiece
Mask-mount PAPR
5-Pt. Strap S/M/L
520500/520600/520700
Mesh Headnet™ S/M/L
520520/520620/520720
* All continuous ow supplied air respirator (CF-SAR) and powered air purifying respirator (PAPR) kit components are
available individually. See Parts List in Section VI.
Belt- mount
PAPR
Components
Blower Kit*:
500085
Breathing Tube:
B420030
5
SURVIVAIR Opti-Fit
Facepiece Kit Belt-mount
PAPR 5-Pt. Strap S/M/L
540510/540610/540710
Mesh Headnet™ S/M/L
541510/541610/541710
Blower/Battery Kit 500085
SURVIVAIR Opti-Fit™ Convertible Facepiece
VI. PARTS LIST
A. Please refer the Parts List Matrix in Part B for component descriptions and identication of their use with the
various operating congurations of the SURVIVAIR Opti-Fit Convertible Facepiece.
2b
APR
29
Headnet
™
Air Purifying Respirator
Cartridges
CF-SAR
SURVIVAIR Opti-Fit Convertible
Facepiece Models
5 Pt. Headstrap
7540/7640/7740
Mesh Headnet
™
7541/7641/7741
CF-Supplied Air
Respirator
Side-mount Breathing Tube
PAPR
CF-Supplied Air
Respirator
Front-mount Breathing Tube
CF-Supplied Air
Respirator
P100 Escape
Powered Air Purifying Respirator
Mask-mounted Blower
Powered Air Purifying Respirator
Belt-mounted Blower
6
SURVIVAIR Opti-Fit™ Convertible Facepiece
B. Parts List Matrix
SURVIVAIR
7
SURVIVAIR Opti-Fit™ Convertible Facepiece
Table 1. Air Purifying Respirator (APR) Filters and
Cartridges
Part No.Protection/Description
Filters
1050P100
1060Filter Pad, N95
1070Filter Pad, N99/R95
1190P100 Slimline
1195P100 Disk
Cartridges
100100Organic Vapors
100200Acid Gases
100300Organic Vapors and Acid Gases
100400Ammonia and Methylamine
100600Mercury Vapor and Chlorine
100800Multi-contaminant
1051Combination Organic Vapors and P100
1052Combination Acid Gases and P100
1053Combination Organic Vapors, Acid Gases, and P100
1054Combination Ammonia, Methylamine, and P100
1056Combination Multi-contaminant and P100
1058Combination Multi-contaminant and P100
Table 2. Continuous Flow Supplied Air Respirator
(CF-SAR) Air Hose Components
985241Light weight hose with OBAC couplings—25 feet
985242Light weight hose with OBAC couplings—50 feet
985244Light weight hose with OBAC couplings—100 feet
930810Quick coupler kit—style: Foster
930820Quick coupler kit—style: Schrader
930830Quick coupler kit—style: Hansen
930840Quick coupler kit—style: OBAC
Table 3. Powered Air Purifying Respirator (PAPR)
Belt-Mounted Cartridges
Part No.Item Description
150100OV Cartridge
150200AG Cartridge
150300OV/AG Cartridge
150400AM/MA Cartridge
158100OV/HEPA Cartridge
158200AG/HEPA Cartridge
158300OV/AG/HEPA Cartridge
158400AM/MA/HEPA Cartridge
108000HEPA Filter
APR Cartridge Considerations:
WARNING
The following is a partial list of materials
that have either poor warning properties, will develop high heats of reaction
with the sorbent in the canister, have
extremely short service times, or will
not be absorbed at all. Respirators cannot be used to protect you against many
of these chemicals. Contact a certied
industrial hygienist or SPERIAN if you
have any of these materials present in
the work place. The use of a respirator
for these materials may lead to personal
injury, illness, or death.
The SURVIVAIR Opti-Fit Convertible is shipped with
side connector port screw caps and a nozzle plug kit
that must be used to congure the facepiece for the
various operating congurations as detailed below.
8
SURVIVAIR Opti-Fit™ Convertible Facepiece
A. Air Purifying Respirator (APR)
The SURVIVAIR Opti-Fit Convertible is shipped from the
factory with the nozzle adapter (item 20, P/N 702045)
installed in the facepiece nozzle. This adapter must be
capped using the included adapter cap (item 24, P/N
420020) for the facepiece to be used as an APR respirator. When attaching the adapter cap, an audible click
should be heard (Figure 1).
Figure 1. Adapter Cap
Figure 4. Insert Nozzle Gasket into Facepiece
If a low prole nozzle setup is desired, the nozzle
adapter can be removed from the facepiece and the
nozzle plug kit installed in its place. Unscrew the nozzle
adapter from the facepiece by pressing down on the
adapter locking tab from inside the lens and turning the
adapter counterclockwise (Figures 2 and 3). Insert the
nozzle gasket (item 25, P/N 763016) into the nozzle
port (Figure 4). Thread in the nozzle plug (item 26, P/N
962066), using a quarter or similar item in the molded
slot to hand-tighten (Figure 5).
Figure 2. Push Down on Adapter Locking Tab
Figure 5. Tighten Nozzle Plug with Coin
in Molded Slot
WARNING
The included screw caps (item 27, P/N
985020) are not to be used on the facepiece side ports when using the SURVIVAIR Opti-Fit Convertible in the air puri-
fying respirator (APR) conguration. See
Section VIII, Part A.1 for installing chemi-
cal cartridges and particulate lters to
the facepiece side connector ports. Failure to comply with this warning may lead
to personal injury, illness, or death.
Figure 3. Remove Adapter
9
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.