Speed Queen Drying Tumblers none User Manual

Drying Tumblers

Refer to Page 4 for Model Identification

NOTA: El manual en español aparece después del manual en inglés.
Installation

50 Pound Capacity 75 Pound Capacity

Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.comlaundry.com
Part No. 70256801R1
August 2007

Installation must conform with local codes or, in the absence of local codes, with:

In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”

In Canada, installation must comply with Standards CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I.

In Australia, installation must comply with the Australian Gas Association Installation Code for Gas Burning Appliances and Equipment.

WARNING
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance. – Do not touch any electrical switch; do
not use any phone in your building.
– Clear the room, building or area of all
occupants.
– Immediately call your gas supplier from
a neighbor’s phone. Follow the gas supplier’s instructions.
– If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be performed by a qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
W033
W052
W053
MISE EN GARDE
POUR VOTRE SÉCURITÉ, les informations de ce guide doivent être respectées afin de réduire les risques d’incendie, d’explosion ou d’éviter les dommages matériels, personnels ou blessures mortelles.
W033R3QU
• Ne pas entreposer ou utiliser d’essence ou toutes autres vapeurs et liquides inflammables à proximité de cette machine ou de tout autre appareil.
• QUE FAIRE EN CAS D’ODEUR DE GAZ : – Ne pas mettre d’appareil en marche. – Ne pas toucher aux interrupteurs
électriques ; ne pas utiliser le téléphone des lieux.
– Évacuer la pièce, le bâtiment ou la zone
de tous les occupants.
– Appeler immédiatement le fournisseur
de gaz de la maison d’un voisin. Respecter les instructions communiquées par le fournisseur.
– Si vous ne pouvez pas joindre le
fournisseur de gaz, appeler le service d’incendie.
• L’installation et l’entretien doivent être effectués par un installateur, service d’entretien qualifiés ou par le fournisseur de gaz.
W052R5QU
POUR VOTRE SÉCURITÉ
Ne pas entreposer ou utiliser d’essence ou toutes autres vapeurs et liquides inflammables à proximité de cette unité ou de tout autre appareil.
W053R2QU
IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the above safety information must be posted in a prominent location near the tumbler for customer use.
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
Table of
Contents
Introduction......................................................................................... 4
Model Identification ............................................................................. 4
Customer Service.................................................................................. 4
Wiring Diagram .................................................................................... 4
Serial Plate Location............................................................................. 5
Safety Information.............................................................................. 6
Important Safety Instructions ............................................................... 7
Specifications and Dimensions........................................................... 9
Cabinet Dimensions.............................................................................. 10
Exhaust Outlet Locations...................................................................... 11
Gas Connection Locations.................................................................... 12
Electrical Connection Locations........................................................... 13
Steam Connection Locations ................................................................ 14
Installation........................................................................................... 15
Pre-Installation Inspection .................................................................... 15
Location Requirements......................................................................... 16
Position and Level the Tumbler............................................................ 17
Installing Accessory Timing Cam ........................................................ 17
Removal of Existing Timing Cam ................................................... 18
Installation of New Timing Cam ..................................................... 18
Before Placing Tumbler into Service ................................................... 19
Required for CE Marked (European) Models Only......................... 20
Installing Gas Drying Tumblers in the European Union (EU) ............. 21
General Information......................................................................... 21
Basic Configuration ......................................................................... 22
Specific Conversion Procedures ...................................................... 22
Exhaust Requirements ....................................................................... 29
Layout ................................................................................................... 29
Make-Up Air......................................................................................... 29
Venting ................................................................................................. 29
Individual Venting ........................................................................... 30
Manifold Venting............................................................................. 31
Gas Requirements............................................................................... 33
Gas Supply Pipe Looping and Sizing ................................................... 35
High Altitude Orifice Sizing................................................................. 37
Steam Requirements........................................................................... 38
Piping Recommendations ..................................................................... 38
Installing Steam Trap and Making Condensate Return Connections... 39
Electrical Requirements..................................................................... 41
Grounding Instructions ......................................................................... 41
Jumper Configuration Instructions ....................................................... 43
Ferrite Ring Installation........................................................................ 43
50 Pound Tumbler Electrical Requirements......................................... 44
75 Pound Tumbler Electrical Requirements......................................... 45
© Copyright 2007, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
2
70256801© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Adjustments......................................................................................... 46
Gas Burner Air Shutter ......................................................................... 46
Airflow Switch...................................................................................... 47
Loading Door Switch............................................................................ 49
Loading Door Strike ............................................................................. 51
Chain Drive........................................................................................... 52
Nonreversing Models....................................................................... 52
Reversing Models ............................................................................ 52
Belt Drive.............................................................................................. 53
Nonreversing Models....................................................................... 53
Reversing Models ............................................................................ 53
Removing Tumbler from Service...................................................... 58
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3

Introduction

Model Identification

Information in this manual is applicable to these models:
Gas Steam/Thermal Oil Electric
ATB50CG AT B 50 C S H DCB50CE
DTB50CG DCB50CSH DTB50CE
DTB50EG DCB50CSL JC50CE
JC50CG DTB50CSH JT50CE
JC50EG DTB50CSL JCB50CE
JCB50CG JCB50CSH JTB50CE
JCB50EG JT50CSH SC50CE
JT50CG JT50CSL SCB50AT
50 Pound
75 Pound
JT50EG JTB50CSH SCB50CE
JTB50CG JTB50CSL STB50CE
JTB50EG SCB50CSH TKD50CEMT
SC50CG SCB50CSL
SC50EG STB50CSH
SCB50CG STB50CSL
SCB50EG
STB50CG
STB50EG
TKD50CGMT
ATB75CG AT B 75 C S H DCB75CE
DTB634 DCB75CSH DTB75CE
DTB75CG DCB75CSL JC75CE
DTB75EG DTB75CSH JCB75CE
JC75EG DTB75CSL JT75CE
JCB75CG JC75CSH JTB75CE
JT75CG JCB75CSH SC75CE
JT75EG JT75CSH SCB75CE
JTB75CG JT75CSL STB75CE
JTB75EG JTB75CSH
SC75CG JTB75CSL
SCB75CG SC75CSH
STB634 SCB75CSH
STB75CG STB75CSH
STB75EG STB75CSL

Customer Service

If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) for the name and address of the nearest authorized parts distributor.
For technical assistance, call (920) 748-3121.
4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
748-3950

Wiring Diagram

The wiring diagram is located in the literature packet supplied with all non-CE Marked models. On CE Marked models, it is located in the junction box.
70256801

Serial Plate Location

When calling or writing for information about your product, be sure to mention model and serial numbers. Model and serial numbers are located on the serial plate as shown.
Introduction
1
1
T453I
1 Serial Plate
Conversion Table
Multiply By To Obtain Multiply By To Obtain
Btu .252 kCal Pounds/sq. inch .06895 Bars
Btu 1055 Joules Pounds/sq. inch .070 kg/sq. cm
Inch 25.4 Millimeters Pounds (lbs.) .454 Kilograms
Inches W.C. .036 Pounds/sq. inch Boiler Horsepower 34479 Btu/hr.
Inches W.C. .249 kPa Boiler Horsepower 34.5 lbs. Steam/hr.
lbf/inch2 (psi) .0369 kPa CFM .471 liters/second
3
ft
28.32 Liters kW 3414 Btu/hr.
T453I
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
5

Safety Information

Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.
DANGER
DANGER indicates the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the danger is ignored.
WARNING
WARNING indicates the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the warning is ignored.
CAUTION
CAUTION indicates the presence of a hazard that will or can cause minor personal injury or property damage if the caution is ignored.
NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.
WARNING
Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage.
W051R1
NOTE: The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumbler. These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumbler.
Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.
Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.
IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.
6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70256801

Save These Instructions

Safety Information

Important Safety Instructions

WARNING
Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive.
W359
1. Read all instructions before using the tumbler.
2. Refer to the Grounding Instructions for the
proper grounding of the tumbler.
3. Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, other flammable or explosive substances as they give off vapors that could ignite or explode.
4. Do not allow children to play on or in the tumbler. Close supervision of children is necessary when the tumbler is used near children. This is a safety rule for all appliances.
5. Before the tumbler is removed from service or discarded, remove the door to the drying compartment and the door to the lint compartment.
6. Do not reach into the tumbler if the cylinder is revolving.
7. Do not install or store the tumbler where it will be exposed to water and/or weather.
8. Do not tamper with the controls.
9. Do not repair or replace any part of the tumbler, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.
10. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.
11. To reduce the risk of fire, DO NOT DRY plastics or articles containing foam rubber or similarly textured rubberlike materials.
13. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt.
14. The interior of the tumbler and the exhaust duct should be cleaned periodically by qualified service personnel.
15. If not installed, operated and maintained in accordance with the manufacturer’s instructions or if there is damage to or mishandling of this product’s components, use of this product could expose you to substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer, birth defects or other reproductive harm.
16. Tumbler will not operate with the loading door open. DO NOT bypass the door safety switch to permit the tumbler to operate with the door open. The cylinder will stop rotating when the door is opened. Do not use the tumbler if the cylinder does not stop rotating when the door is opened or starts rotating without pressing or turning the START mechanism. Remove the tumbler from use and call for service.
17. Do not put articles soiled with vegetable or cooking oil in the tumbler, as these oils may not be removed during washing. Due to the remaining oil, the fabric may catch on fire by itself.
18. To reduce the risk of fire, DO NOT put clothes which have traces of any flammable substances such as machine oil, flammable chemicals, thinner, etc. or anything containing wax or chemicals such as in mops and cleaning cloths, or anything dry-cleaned at home with dry-cleaning solvent in the tumbler.
19. Use the tumbler only for its intended purpose, drying fabrics.
20. ALWAYS disconnect and lockout the electrical power to the tumbler before servicing. Disconnect power by shutting off appropriate breaker or fuse.
21. Install this tumbler according to the manual. All connections for electrical power, grounding, and gas supply must comply with local codes and be made by licensed personnel when required.
12. Always clean the lint filter daily.
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7
Safety Information
22. Remove laundry immediately after tumbler stops.
23. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of reach of children at all times (preferably in a locked cabinet).
24. Do not tumble fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.
25. Always follow the fabric care instructions supplied by the garment manufacturer.
26. Never operate the tumbler with any guards and/or panels removed.
27. DO NOT operate the tumbler with missing or broken parts.
28. DO NOT bypass any safety devices.
29. Solvent vapors from dry-cleaning machines create acids when drawn through the heater of the drying unit. These acids are corrosive to the tumbler as well as to the laundry load being dried. Be sure make-up air is free of solvent vapors.
30. Failure to install, maintain, and/or operate this machine according to the manufacturer’s instructions may result in conditions which can produce bodily injury and/or property damage.
WARNING
To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
W055
This machine is intended for commerical use.
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70256801

Specifications and Dimensions

Specifications 50 Pound 75 Pound 634 Net Weight: Pounds (kg) Cylinder Size: Inches (mm) Cylinder Capacity (Dry Weight):
Pounds (kg) Air Outlet Diameter: Inches (mm) Maximum Static Back Pressure:
W.C.I. (mbar)
Maximum Airflow: C.F.M. (l/sec.)
Gas Connection
Gas Consumption: Btu/hr (Mj/hr)
Heating Elements: Watts
All Models Except EG
EG Models 390 (184) 500 (236) Not Applicable
CG Models 120,000 (126.6) 165,000 (174.1) 215,000 (227)
EG Models 95,000 (100.2) 140,000 (147.7)
545 (247) 615 (279) 710 (322)
37 x 30 (940 x 762) 37 x 36 (940 x 914) 37 x 36 (940 x 914)
50 (22.7) 75 (34) 75 (34)
8 (203) 8 (203) 10 (254)
0.5 (1.3) 0.5 (1.3) 0.5 (1.3)
750 (354) 750 (354)
CG: 920 (434)
Gas Models
1/2 in. NPT 1/2 in. NPT 3/4 in. NPT
Electric Models
21,000 (240 V/50 Hertz)
30,000 (other voltages)
30,000
1100 (518)
Not Applicable
Steam Connection
Steam Consumption: Boiler Horsepower (Btu)
Nonreversing
Reversing
Steam Models
3/4 in. NPT 3/4 in. NPT Not Applicable
6 coil
(SH Models)
4 coil
(SL Models)
Fan 1/3 1/3 1
Cylinder 1/3 1/3 1/3
4.6
(154,000)
3.0
(100,400)
Motor Horsepower
50 Pound 75 Pound 634
1/2 3/4 Not Applicable
4.6
(154,000)
4.0
(133,900)
Not Applicable
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
Specifications and Dimensions

Cabinet Dimensions

C
B
D
A
E
Models A B C D E
50CG 50EG 50CE
50CSH 50CSL
75CG 75EG 75CE
75CSH 75CSL
DTB634 STB634
30.75 in.
(781 mm)
30.75 in.
(781 mm)
30.75 in.
(781 mm)
30.75 in.
(781 mm)
30.75 in.
(781 mm)
28.25 in.
(717 mm)
28.25 in.
(717 mm)
28.25 in.
(717 mm)
28.25 in.
(717 mm)
28.25 in.
(717 mm)
47 in.
(1194 mm)
47 in.
(1194 mm)
53 in.
(1346 mm)
53 in.
(1346 mm)
53 in.
(1346 mm)
76.625 in.
(1946 mm)
80 in.
(2032 mm)
76.625 in.
(1946 mm)
80 in.
(2032 mm)
76.625 in.
(1946 mm)
38.625 in. (981 mm)
38.625 in. (981 mm)
38.625 in. (981mm)
38.625 in.
(981 mm)
38.625 in.
(981 mm)
T326I
T326I
10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70256801

Exhaust Outlet Locations

Specifications and Dimensions
A
C
B
Horizontal Exhaust
Vertical Exhaust
C
50EG
A
Models A B C
50CG 50CE
50CSL
5.375 in.
(137 mm)
8 in.
(203 mm)
13.375 in. (340 mm)
50CSH
75CG 75CE
75CSH
5.375 in.
(137 mm)
8 in.
(203 mm)
13.375 in. (340 mm)
75CSL
DTB634 STB634
75EG 5.625 in.
50EG 5.625 in.
6.5 in.
(165 mm)
(143 mm)
(143 mm)
10 in.
(254 mm)
8 in.
(203 mm)
8 in.
(203 mm)
6.5 in.
(165 mm)
5 in.
(127 mm)
T492I
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
11
Specifications and Dimensions

Gas Connection Locations

B
A
Models Diameter A B
50CG 50EG
75CG 75EG
DTB634 STB634
1/2 in. NPT 15.5 in.
(394 mm)
1/2 in. NPT 15.75 in.
(400 mm)
3/4 in. NPT 15.75 in.
(400 mm)
65.75 in.
(1670 mm)
65.75 in.
(1670 mm)
65.75 in.
(1670 mm)
T329I
12
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70256801

Electrical Connection Locations

Specifications and Dimensions
A
B
B
A

GAS AND STEAM ELECTRIC

Models A B
50CG/50EG
50CSH/50CSL
(MT/CD) 3 in. (76.2 mm)
(OM) 9.5 in. (241 mm)
75CG/75EG
75CSH/75CSL
DTB634/STB634
50CE/75CE 19 in. (483 mm) 64 in. (1626 mm)
NOTE: These figures are approximate dimensions only.
T330I
T330I
(MT/CD) 72 in. (1067 mm)
(OM) 63.5 in. (1613 mm)
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
Specifications and Dimensions

Steam Connection Locations

B
A
C
D
Models Diameter A B C D
50CSH 50CSL
75CSH 75CSL
3/4 in. NPT 15.25 in.
(387 mm)
3/4 in. NPT 15.25 in.
(387 mm)
72.75 in.
(1848 mm)
72.75 in.
(1848 mm)
7.5 in.
(190 mm)
7.5 in.
(190 mm)
64.75 in.
(1645 mm)
64.75 in.
(1645 mm)
T328I
14
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70256801

Installation

Pre-Installation Inspection

Upon delivery, visually inspect the packaging and portions of the product visible through the packaging for shipping damage. If the package or product is damaged, or if signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.
Remove the packaging as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.
IMPORTANT: Remove the shipping tape from the two backdraft dampers located in the exhaust outlet.
IMPORTANT: Warranty is void unless tumbler is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed in this manual and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.
Materials Required (Obtain Locally)
All Models
Gas Models
Steam Models
One fused disconnect switch or circuit breaker.
One gas shut-off valve for gas service line to each tumbler.
One steam shut-off valve for steam service line to be connected upstream of solenoid steam valve.
Two steam shut-off valves for each condensate return line.
Flexible steam hoses with a 125 psig (pounds per square inch gauge) (8.79
kg/sq. cm) working pressure for connecting steam coils. Refer to Figure 15 for sizing and connection configurations.
Two steam traps for steam coil outlet to condensate return line.
Two vacuum breakers for condensate return lines.
IMPORTANT: Keep tumbler area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
15
Installation

Location Requirements

A typical tumbler enclosure is shown in Figure 1. Note that the enclosure touches the tumbler top and side
The tumbler must be installed on a level floor. Floor covering materials such as carpeting or tile must be removed.
panels. Also, note the minimum and maximum dimensions. There may be local codes and ordinances which must be complied with.
To assure compliance, consult local building code requirements.
The tumbler MUST NOT be installed or stored in an area where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the
To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.
WARNING
rear of the tumbler with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumbler.
IMPORTANT: Install tumblers with sufficient clearance for servicing and operation. Refer to Figure 1.
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances.
2
W055
W056
3
1
7

NOTE: Shaded areas indicate adjacent structure.

1 Zero Clearance Permitted for First 4 in. (102 mm) 2 4 in. (102 mm) Maximum Header Thickness 3 12 in. (305 mm) Minimum Clearance Permitted for Remainder 4 Guard 5 Provision for Make-Up Air 6 24 in. (610 mm) Minimum – 36 in. (914 mm) Recommended for Maintenance Purposes 7 Zero Clearance
4
5
6
TMB815N
TMB815N
16

Figure 1

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70256801
Loading...
+ 42 hidden pages