OPERATING INSTRUCTIONS
CC-80 and CC-81
Fluorescence Analysis Cabinets
CC-81
Manual No. AM11028
Printed in U.S.A. Issued: September 2011
![](/html/97/97f5/97f5d3e46850e06c10305f5d77e713c40f4b006622c5249ad554fa0e01098c8a/bg2.png)
INTRODUCTION
The Spectroline CC-80 and CC-81 cabinets are specially designed for
efficient fluorescence analysis. Both units come equipped with a 25-watt
internal white light source, while the CC-81 is additionally supplied with
the Spectroline ENF-280C 365/254nm 8-watt UV lamp.
For a list of E-Series lamp models that work with either the CC-80 or CC-81
cabinets, please visit www.spectroline.com. Choose from the available
8-watt lamps listed under "E-Series Ultraviolet Hand-Held Lamps."
For greater epillumination options, these cabinets may be used with one
or two Spectroline E-Series UV lamps that are available in 254nm,
312nm or 365nm, or a combination of these wavelengths. For higher
UV intensity and increased fluorescent contrast with transillumination,
these units may be placed over a wide range of Spectroline UV
transilluminators.
WARNING
Please read the instructions in this manual carefully. Never use
this equipment in any manner not specified in these instructions
because the protection provided by the equipment may be
impaired.
CABINET DESCRIPTION
1. Eyepiece Flexible eyepiece with UV-absorbing viewing
Viewing Assembly window to protect the eyes and increase contrast.
2. Photographic Port Used when photographing samples. To expose,
remove the viewing assembly.
3. Master Power Controls power supply to the cabinet.
Switch
4. White Light Switch Controls the white light bulb.
5. Port Covers Cover the lamp port openings to ensure that
the cabinet is lighttight.
6. Lamp Ports Accommodate one or two E-Series* lamps.
7. Curtain Excludes ambient light.
8. Lamp Outlets Receptacles for plugs of E-Series* lamps.
*Use with any 8-watt Spectroline E-Series UV lamp.
2
![](/html/97/97f5/97f5d3e46850e06c10305f5d77e713c40f4b006622c5249ad554fa0e01098c8a/bg3.png)
1. Eyepiece Viewing Assembly
2. Photographic Port
(under viewing
assembly)
5. Port Cover
6. Lamp Port
(under
port
cover)
7. Curtain
3. Master Power Switch
4. White Light Switch
CC-80
8. Lamp Outlets
UNPACKING AND INSPECTION
1. Carefully unpack and inspect the cabinet for possible damage in
shipment. If any damage is noted, immediately notify the carrier and
supplier before attempting to use the equipment.
2. Save the shipping carton and packing materials for future storing and
shipping of the equipment.
3. Check the lamp’s electrical performance as soon as possible
according to the GENERAL FUNCTIONAL CHECKS outlined in the
‘‘OPERATION’’ section of this manual.
OPERATION
GENERAL FUNCTIONAL CHECKS
1. Connect the cabinet plug to a power outlet that complies with the
electrical requirements specified on the unit’s label.
2. Depress the master switch to the ON position. This switch must be
activated to operate the E-Series UV lamp(s) or the white light bulb.
3. Test the white light bulb by pushing the white light switch ON.
4. Check the felt curtain by pushing it inward and upward until
it connects with the magnetic catch. This will allow clear
placement of samples.
3