Technical Bulletin 05-10 
SpectraLink Drop Test Description 
Date:  10/11/2005    Originator: Jason Malone 
Software Version:  Any    Approvers: 
Hardware Version:  Any 
Product Type:  Link WTS, NetLink Wireless Telephones  Status: 
Access Level:   General    Revision: A 
Description 
This document briefly describes SpectraLink’s standardized drop test method and pass-fail criteria.  
SpectraLink’s drop test is derived from the free fall testing procedure defined in IEC/ANSI 60068-2-32 and 
enables reproducible assessments of the drop test performance and durability of SpectraLink Link WTS and 
NetLink Wireless Telephones. 
Drop Test Methodology 
The test is designed to simulate falls which a given handset model might undergo during normal operation, 
and to verify that it meets or exceeds the handset’s durability specification. It is based on falls in random 
orientation onto a hard unpadded (ceramic) floor surface from a specified drop height (listed in the table 
below). After each fall, the victim device is visually examined and electrically and mechanically verified, as 
outlined below.  
Drop Test Sampling 
In an effort to ensure consistent maximum quality of newly manufactured products, SpectraLink performs 
these tests with a statistically significant sample and on a quarterly basis. 
Drop Test Pass Criteria 
After each drop:    
•The handset must be capable of being registered to a system 
•The handset must be capable of placing and receiving calls with voice quality indistinguishable from newly 
manufactured devices 
•No mechanical PC board damage or sign of loose components are evident 
•Cosmetic scratching or scarring to the plastic enclosure are acceptable; however, broken or cracked 
enclosures are not acceptable 
•Separation and/or damage to the Battery Pack, including battery failures, are acceptable  
Handset Specifications 
Each SpectraLink Wireless Telephone has a durability specification that includes drop test survivability, as 
listed in the following table:  
Model  Survivable drop test height 
NetLink e340 Wireless Telephone  5 feet 
NetLink h340 Wireless Telephone  10 feet 
NetLink i640 Wireless Telephone  24 feet 
Link Wireless Telephone  24 feet 
Link and NetLink PTBxxx Wireless Telephones  24 feet 
THE INFORMATION PROVIDED IN THE SPECTRALINK TECHNICAL BULLETIN IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. NO 
OBLIGATION OR LIABILITY WILL ARISE OUT OF, SPECTRALINK RENDERING TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION HEREWITH. 
SpectraLink Corporation  •  5755 Central Avenue  •  Boulder, Colorado 80301  •  303.440.5330  •  Fax 303.440.5331