Spectra nTier500 Installation Manual

Page 1
Spectra nTier500 and
nTier500 VTL
Rack-mount Installation Guide
SpectraLogic.com
Page 2
Copyright Copyright © 2009 Spectra Logic Corporation. All rights reserved. This item and the
information contained herein are the property of Spectra Logic Corporation.
Notices Except as expressly stated herein, Spectra Logic Corporation makes its products and
associated documentation on an “AS IS” BASIS, WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, BOTH OF WHICH ARE EXPRESSLY DISCLAIMED. In no event shall Spectra Logic be liable for any loss of profits, loss of business, loss of use or data, interruption of business, or for indirect, special, incidental or consequential damages of any kind, even if Spectra Logic has been advised of the possibility of such damages arising from any defect or error.
Information furnished in this manual is believed to be accurate and reliable. However, no responsibility is assumed by Spectra Logic for its use. Due to continuing research and development, Spectra Logic may revise this publication from time to time without notice, and reserves the right to change any product specification at any time without notice.
Part Number 90990047 Revision B
Revision
History
Revision Date Description
A February 2009 Initial release
B April 2009
Update to reflect rebranding of nTier300 VTL to nTier500 VTL
Contacting
Spectra Logic
To obtain general information Spectra Logic Web Site: www.spectralogic.com United States Headquarters European Office
Spectra Logic Corporation 1700 North 55th Street Boulder, CO 80301 USA
Phone: 1.800.833.1132 or 1.303.449.400 International: 1.303.449.6400 Fax: 1.303.939.8844
SpectraGuard Technical Support Web Site: www.spectralogic.com/support United States and Canada
Phone:
Toll free US and Canada: 1.800.227.4637 International: 1.303.449.0160
Email: support@spectralogic.com
Mexico, Central and South America, Asia, Australia, and New Zealand
Phone: 1.303.449.0160 Email: support@spectralogic.com
Spectra Logic Europe Ltd. Magdalen Centre Robert Robinson Avenue Oxford Science Park OXFORD OX4 4GA United Kingdom
Phone: 44 (0) 870.112.2150 Fax: 44 (0) 870.112.2175
Knowledge Base: www.spectralogic.com/knowledgebase Europe, Middle East, Africa
Phone: 44 (0) 870.112.2185 Email: support@spectralogic.com
Deutsch sprechende Kunden
Phone: 49 (0) 6028.9796.507 Email: spectralogic@stortrec.de
2
Rack-Mounting Instructions
Page 3
Rack-Mounting Instructions
Warning
Warning
Warning
These instructions describe how to install the Spectra nTier500 or nTier500 VTL (the nTier appliance) in a standard 19-inch, four-post rack. Do not install the data drives until after the rack-mounting procedure is completed.
Before You Begin
Perform these tasks, obtain these items, and note the warnings:
Identify the location where you will install the Spectra nTier appliance.Assemble the rack, if necessary.Obtain the following tools and equipment:
#2 Phillips screwdriver, magnetic if availableMeasuring tape (recommended)Level (recommended)
Ensure Rack Stability
The rails provided with the library are designed for a standard 4-post 19-inch (48 cm) rack.
German: Die Schienen, die mit der nTier sind für ein Standard-4-post-19-Zoll (48 cm) Rack.
If you are not installing any other equipment in the rack, install the Spectra nTier appliance near the bottom of the rack to prevent the rack from being top-heavy.
German: Wenn Sie nicht die Installation ein anderes Gerät im Rack, installieren Sie die Spectra nTier in der Nähe der Unterseite des Schranks zu verhindern, dass der Schrank von der kopflastigen.
The nTier appliance weighs approximately 54 lb. (25 kg) without drives installed. Use extreme caution when moving it. Always use two people, one on each side, when lifting or moving it.
German: Die nTier Gerät wiegt ca 25 kg., ohne Laufwerke installiert. Verwenden Sie extreme Vorsicht walten lassen, wenn sie abwandern. Benutzen Sie immer zwei Personen, eine auf jeder Seite, beim Heben oder Fortbewegen.
A 2-post rack will not support the weight of the
A 2-post-Rack wird nicht das Gewicht der nTier
nTier appliance.
.
3
Page 4
Warning
To reduce the risk of personal injury or damage to equipment:
Rail assemblies
Small screws
Small nut plates and screws
Extend leveling jacks to the floor. Ensure that the full weight of the rack rests on the leveling jacks. Install stabilizing feet on the rack. In multiple-rack installations, secure racks together. Extend only one rack component at a time. Racks may become unstable if more
than one component is extended.
German: Sicherheitshinweise zur Vermeidung von Verletzungen und Beschädigungen:
Stellen Sie sicher, dass die Standfüße des Racks den Boden vollständig
berühren das Gewicht des Racks vollständig auf den Standfüßen ruht.
Installieren Sie nötigenfalls stabilisierende Komponenten im Rack. Sofern Sie mehrere Racks nebeneinander installieren, fixieren Sie diese
untereinander.
Ziehen Sie immer nur eine Rack-Komponente aus dem Rack. Das gleichzeitige. Ziehen mehrerer Komponenten kann dazu führen dass das Rack nach vorne
kippt.
Identify the Rack-mount Kit Components:
Component # Required Use
2 rail assemblies Mount chassis in rack. Each
assembly includes:
RailSliderExtender plate
Bag labeled 6 or more screws
Bag labeled
4 small nut plates12 (or more)
screws
1 RAIL.
2
Attach rail sliders to chassis.
Attach rail assemblies to rack.
4
Rack-Mounting Instructions
Page 5
Component # Required Use
Large nut plates and screws
Clip nuts and screws
Press up to release safety latchSlider Outer rail
Bag labeled 3
4 large nut plates12 (or more)
screws
Bag labeled
4 clip nuts4 screws
4
Attach rail assemblies to rack.
Secure nTier appliance to rack.
INSTALL THE RAILS
Each rail assembly consists of an inner slider that is attached to the nTier appliance and an outer rail that is attached to the rack.
Prepare the Rails
Disassemble the rail assemblies.
1. Extend the slider from the outer rail until the safety latch is visible, as
shown in Figure 1.
2. Press up on the latch as shown in Figure 1 to release the latch.
Figure 1 The safety latch and mounting holes.
3. Pull the slider completely out of the outer rail.
4. Repeat steps 1–3 for the second rail assembly.
April 2009
Spectra nTier500 and nTier500 VTL
5
Page 6
Install the Sliders on the Chassis
Latch
Rear of chassis
Ta b
Front of chassis
1. Remove the nTier appliance from its bag and place it on a sturdy work
surface where you can reach both sides of the chassis. Having two people for this task simplifies lifting and moving the chassis.
2. Position a slider against one side of the chassis with the latch toward
the rear of the chassis and pointing toward the front of the chassis. Make sure the safety latch is toward the outside.
o
Figure 2 Position the latch toward the rear.
3. Slide the end of the slider (furthest from the latch) under the tab near
the front of the chassis so that the tab fits into the notch on the end of the slider.
o
Figure 3 Insert the slider under the tab.
6
Rack-Mounting Instructions
Page 7
4. Position the slider so that the three holes circled in Figure 9 align with
Screws
Important
the holes in the side of the chassis.
5. Use a #2 Phillips screwdriver to install a screw from bag 1 into each
hole, securing the slider to the chassis. Tighten the screws snugly.
Note: If you cannot align the three holes circled in Figure 9 with the
holes in the chassis, use the other screw holes in the slider to install the screws. You only need three screws to attach the slider to the chassis.
o
Figure 4 Attach the slider to the chassis.
6. Repeat Steps 2 through 5 to attach the second slider to the other side of
the chassis.
Adjust the Length of the Outer Rails
The length of the rails must be adjusted before they are attached to the rack.
1. If necessary, loosen the screws attaching the extender to the outer rail so
that you can adjust the length of the rail. See Figure 10 to see a close-up of the rail with the extender attached.
o
Figure 5 Adjust the position of the extender attached to rail end.
2. Position one of the rails against the inside of the rack with the extender
toward the back of the rack.
April 2009
Spectra nTier500 and nTier500 VTL
7
Page 8
3. Adjust the position of the extender so that the assembled rail just fits in
2 inches
Nut Plate
Screws
the inside distance from the front mounting holes of your rack to the back mounting holes.
Note: Using a measuring tape simplifies determining the length
required for the rails to fit inside the rack.
4. Tighten the four screws holding the extender to the rail.
5. Repeat Steps 1 through 4 for the other rail.
Install the Outer Rails in the Rack
1. Examine the mounting holes in your rack and select the set of nut plates
and screws (either bag 2 or bag 3 in the rack kit) that best match these holes.
2. Determine where to install the nut plates on the rack. The plates must
be positioned to provide at least 2 inches of clearance below the bottom edge of the plate.
3. Position a nut plate behind one rack post at the desired position, then
use a #2 Phillips screwdriver to screw three ½-inch screws into the plate, as shown in Figure 11. Tighten the screws only enough to hold the plate in place.
o
4. Repeat Step 3 to install the nut plates on the each of the other three
posts of the rack.
Note: Make sure that the nut plates are installed at the same level on
8
Rack-Mounting Instructions
Figure 6 Loosely attach the nut plate to the rack.
all four posts. Otherwise the rails will not be level when they are installed. Using a level simplifies positioning the nut plates so that the rails will be level.
Page 9
5. Fit the tabs on one rail extender between the nut plate and one of the
Ta bs
Front
(behind post)
Rear
Ta bs
Clip nut
Clip nut
Empty hole
Empty hole
Mounting screws for nut plate
back rack legs. Then, fit the front tabs on the rail between the nut plate and corresponding legs on the front of the rack. Tighten all three screws to secure the nut plate to the rack.
o
Figure 7 Insert the rail tabs between the nut plate and the rack.
6. Repeat Step 5 to attach the second outer rail to the rack. Set aside any
leftover screws and parts.
7. On the front of the rack, attach two clip nuts (bag 4 in the rack kit), to
each leg. Place one above and another below the rails, with one empty hole separating each clip nut from the nut plate mounting screws, as shown in Figure 13.
o
April 2009
Figure 8 Attach clip nuts to the front of the rack.
Spectra nTier500 and nTier500 VTL
9
Page 10
INSTALL THE NTIER APPLIANCE INTO THE RACK
Warning
Caution
The nTier appliance weighs approximately 54 lb. (25 kg) without drives installed. Use extreme caution when moving it. Always use two people, one on each side, when lifting or moving it.
German: Die nTier Gerät wiegt ca 25 kg., ohne Laufwerke installiert. Verwenden Sie extreme Vorsicht walten lassen, wenn sie abwandern. Benutzen Sie immer zwei Personen, eine auf jeder Seite, beim Heben oder Fortbewegen.
Do not install the data drives until after you secure the chassis to the rack. A fully loaded nTier appliance is heavy. Most of the weight is toward the front of the chassis.
1. Lift the nTier appliance and slide it onto the rails in the rack until the
mounting ears on the front of the chassis fit against the rack, with the mounting ear screw holes directly over the clip nut holes (see Figure 9).
Figure 9 Slide the chassis into the rack.
10
Rack-Mounting Instructions
Page 11
2. Use a #2 Phillips screwdriver to install the two clip nut screws in each
Screw
Screw
Mounting ear
mounting ear to secure the chassis to the rack.
Figure 10 Secure the chassis to the rack (left side shown)
3. The rack installation is now complete. Continue with the installation as
described in the documentation that accompanied your nTier appliance.
April 2009
Spectra nTier500 and nTier500 VTL
11
Page 12
Notes
12
Rack-Mounting Instructions
Loading...