SECTOR ID : SECTOR01□□□ SECTOR START: XXX.X.XX.X SECTOR END : XXX.X.XX.X SAVE
SAVE
□□
PATT TIT LE PATT ERN01
DATA FIL L 100%
ACTION
PRESET NO : 01
EXIT
SAVE
EXIT
SAVE
EXIT
DWELL TIME 10
SPEED : 200°/S
SAVE AND EXIT
[INITIALIZATION]
[TOUR CLEAR]
[PRESET CLEAR]
[SYSTEM STATUS]
PROTOCOL : PELCO D,P BAUD RATE: 2400BPS
OSD DISPLAY
CAMERA ID: OFF/ON PRESET ID: OFF/ON SECTOR ID: OFF ON COORDINATE:ON/OFF [PREVIOUS PAGE]
NEXT PAGE
[OSD DISPLY]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT [REVIOUS PAGE]
FIRMWARE VER.:2.00
UPGRADED DATE: 06.28,06
CAMERA MODULE: SDM100
[PREVIOS PAGE]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
MAIN MENU
DOME SETUP CAMERA SET AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
SECTOR
EXIT
54
3) WDR Camera (IP-WDRB1)
SPECO MAIN MENU
IP Camera User’s Manual Speco Technologies
PRESETS
DEFAULT / INDOOR / OUTDOOR / CUSTOM
SET UP ID
DISPLAY ID : (OFF / ON)
CAMERA ID : 8 CHARACTER
ID POSITION : (UP-LEFT / UP-CENTER / UP-RIGHT
LENS SELECT
DC
MANUAL
WDR
AUTO
OFF
MANUAL : (WDR BIAS Range -20 to 20 / W DR RANGE 0 to 36)
WB CONTROL
ATW(Range 2K~11K)
AWB
MANUAL (Range 2K ~11K)
LOW LIGHT
SLOW SHUTTER : (SHUTTER LIMIT Range OFF~X32 / AGC CONTROL Range 0 to 60)
AUTO D/N
SPECIAL
VIDEO : (NTSC / PAL)
FLIP : (OFF / ON)
SYNC : (L,LOCK / INT / INT2)
BACK LIGHT : (OFF / ON : BACK LIGHT ZONES )
RESOLUTION : (NORMAL / HIGH / C_NORMAL / C_HIGH )
COLOR MODE : (COLOR / B/W )
SHARPNESS : ON (Range -8 to 8) / OFF
EXIT MENU
EXIT NO CHANGE
SAVE NEW AND EXIT
RESTORE FACTORY SETTING
RELEASE VERSION
55
IP Camera User’s Manual Speco Technologies
I
T
E
F
5.2.2. OSD Menu Setting
When you control the OSD by using the joystick on the camera, refer to the following (select
models only)
UP
R
L
G
H
T
DOWN
When you control by the five keys on the Webviewer GUI refer to the following
56
SETUP
IP Camera User’s Manual Speco Technologies
Notes
5.2.3. Operating Camera OSD Menu (Intensifier Cameras)
1. Press the SET button to access the SETUP mode.
SET UP menu is displayed on the monitor screen.
2. Select the desired feature using the UP or DOWN button.
Each time you press the UP or DOWN button, the arrow
indicator moves up or down.
3. Change the status of the selected feature using the LEFT or
RIGHT button.
If you press RIGHT or LEFT button, it appears available status.
Press the button when gets desired feature.
4. When completed, move the arrow indicator to ‘EXIT" and press
the SET button.
You can access submenu using SET button.
For the mode with ’---‘, you may not access submenu.
57
IP Camera User’s Manual Speco Technologies
1) Setting up the LENS
Select the lens pressing the RIGHT button.
① On the SETUP menu screen, move the arrow indicator to the lens
using the UP or DOWN button.
② Select the desired feature using the LEFT or RIGHT button.
58
▶When DC LENS selected, press SET button to control the
BRIGHTNESS.
IP Camera User’s Manual Speco Technologies
59
IP Camera User’s Manual Speco Technologies
‘
1) Shutter status and speed control
You can control brightness of the screen by the shutter speed.
① Press the SET button to display the setup menu and move the arrow
indicator to ‘SHUTTER’ using the UP or DOWN button.
② Set
SHUTTER’ to the desired mode using the LEFT or RIGHT button.
▶ OFF : Deactivation
▶ FLK(1/100) : Flicker mode
(When WDR is on, the image can flicker a little.)
60
IP Camera User’s Manual Speco Technologies
▶MANUAL : When setting shutter speed manually.
(Only for LENS mode)
You can select speed from ‘1/60’ to ‘1/200,000’sec
61
▶ESC : You can control the BRIGHTNESS.
IP Camera User’s Manual Speco Technologies
③When completed, press ‘SET’
62
IP Camera User’s Manual Speco Technologies
3) SLC (Speco Light Compensation) - BACKLIGHT
A built-in SR chip provides intelligent light level control to overcome
severe Backlight conditions.
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘BACKLIGHT’ using the UP or DOWN button.
② SET ‘BACKLIGHT’ to the desired mode using the LEFT or RIGHT button.
▶HIGH ▶MIDDLE ▶LOW ▶OFF
63
IP Camera User’s Manual Speco Technologies
3) AUTO GAIN CONTROL (AGC)
AGC is to get bright picture. Higher GAIN level, getting brighter screen.
But you can get noise increase.
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘AGC’ using the UP or DOWN button.
② SET ‘BACKLIGHT’ to the desired mode using the LEFT or RIGHT button.
▶ON ▶OFF
64
5) WHITE BALANCE (WHITE BAL.)
‘
select this
IP Camera User’s Manual Speco Technologies
For color control on the screen, use
WHITE BALANCE’ function.
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘WHITE BALANCE’ using the UP or DOWN button.
② Set ‘WHITE BAL.’ to the desired mode using LEFT or RIGHT button.
▶ ATW (Auto Tracking White Balance)
: When color temperature is 2400~12000K,
mode.
(ex. A fluorescent lamp, outdoor)
▶ AWC (Auto White Balance Control)
: The white balance is automatically adjusted in a specific environment.
In order to obtain the best result, press the set button while the camera
focuses on white paper. If the environment including the light source is
changed, you have to adjust the white balance again.
65
IP Camera User’s Manual Speco Technologies
▶MANUAL : To fine adjust, select the Manual mode. You can increase
or decrease the red or blue factor while monitoring the difference on the
screen. Set to ‘MANUAL’ mode and press the SET button. Increase or
decrease the value for RED(R-Gain) and BLUE(B-Gain), watching the color
of the picture, and press the SET button when you obtain the best color.
Notes
Proper White Balance may not be obtained under the following conditions
in these cases select the AWC mode.
When the scene contains mostly high color temperature object, such as
a blue sky or sunset.
When the scene is dim.
If your camera faces fluorescent lamp directly or is installed in the place
of the changing illumination.
66
IP Camera User’s Manual Speco Technologies
6) Digital Noise Reduction (Dynamic Noise Reduction)
DNR is to reduce the noise on the screen.
① Press the SET button to display the SETUP menu and move the
arrow indicator to ‘DNR’ using the UP or DOWN button.
② SET ‘DNR’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶LOW : Low reduction of the noise
▶MIDDLE : Middle reduction of the noise
▶HIGH : High reduction of the noise
Notes
If you change the ‘GAIN’ menu from AGC-L to AGC-H
sensitivity is increased as well as noise on the screen.
When selected ‘GAIN’ menu OFF, DNR will not work.
67
IP Camera User’s Manual Speco Technologies
7) INTENSIFIER
Allows you to get clear images with this function under night
or low light conditions
① Press the SET button to display the SETUP menu and move the
arrow indicator to ‘Intensifier’ using the UP or DOWN button.
② SET ‘Intensifier’ to the desired mode using the LEFT or RIGHT button.
▶AUTO : When your camera is under night or low-lighting level,
select this mode.
Notes
If you press SETUP button at ‘AUTO’ menu, you can control the
lowlight action maximum magnifications.(X2~X128)
Increasing the amount of Intensification results in brighter pictures
Under low light conditions, and may increase image lag.
Increasing the amount of intensification may cause image noise
which is to be expected as a normal condition.
68
IP Camera User’s Manual Speco Technologies
8) NEXT PAGE
① Press the SET button to display the SETUP menu and move the
arrow indicator to ‘Intensifier’ using the UP or DOWN button.
② SET ‘Intensifier’ to the desired mode using the LEFT or RIGHT button.
(A) CAMERA TITLE
① Press the SET button to display the SETUP menu and move the arrow
indicator to ‘CAMERA TITLE’ using the UP or DOWN button.
② SET ‘ON’ using the LEFT or RIGHT button.
Notes
If the CAMERA ID feature is set to ‘OFF’, the name will not displayed
in the monitor.
69
IP Camera User’s Manual Speco Technologies
③ Press SET button to access the SETUP mode.
④ You can enter up to 15 characters.
a. Move the cursor to character-enter location by using the LEFT
or RIGHT button.
b. Select the desired character by using the UP or DOWN button.
c. Press SET button to confirm the blinking character. The first
character is saved and the cursor in the bottom of the screen
moves to the next position.
d. Repeat steps a, b and c until you create the full name you want.
e. Select the position at which the CAMERA TITLE will b located on
the screen.
Notes
If the CAMERA TITLE feature is set to ‘OFF’, the name will not displayed
in the monitor.
After erasing the character from right to left, correct the character again.
70
IP Camera User’s Manual Speco Technologies
OSD Key may not work for 3 seconds when the COLOR/ BW mode is
B) COLOR
You can choose color and B/W mode electronically. (OPTION)
Notes
changed.
▶ ON : color mode
▶ OFF : B/W mode
▶ AUTO : generally color mode, B/W mode in low luminance.
71
IP Camera User’s Manual Speco Technologies
Press the SET button to display the setup menu and move the arrow indicator
Notes
C) SYNC
Two SYNCHRONIZATION modes are available… INTERNAL and EXTERNAL
LINE-LOCK. In LINE-LOCK mode, the camera syncs to the 60 Hz phase.
①
to ‘SYNC’ using the UP and DOWN button.
② SET to the desired mode using the LEFT or RIGHT button.
▶ INT : Internal synchronization
▶ L/L : If you choose ‘L/L’, you can adjust the desired phase.
- Press the SET button.
- You can adjust the desired phase from 0 to 270.
Line Lock is only available in the 24 volt AC mode of operation.
In 12 volts DC, the SYNC menu is always in the ‘INTERNAL’ mode.
72
IP Camera User’s Manual Speco Technologies
Move the arrow indicator to area you want to
s
D) PRIVACY
To mask an area that you want to be private.
① Press the SET button to display the setup menu and move the arrow
indicator to ‘PRIVACY’ using the UP and DOWN button.
② SET ‘PRIVACY’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶ON : PRIVACY mode activated
-Press the SET button.
mask.
-Set ‘ON’ using LEFT or RIGHT button.
-Press the SET button and then set the area’
bounds
with the method like MOTION DET. set
73
IP Camera User’s Manual Speco Technologies
E) REVERSE
① Press the SET button to display the setup menu and move the arrow
indicator to ‘REVERSE’ using the UP and DOWN button.
② SET ‘REVERSE’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶ON : Make a reverse turn to RIGHT or LEFT.
74
IP Camera User’s Manual Speco Technologies
F) DETAIL
① Press the SET button to display the setup menu and move the arrow
indicator to ‘DETAIL’ using the UP and DOWN button.
② SET ‘DETAIL’ to the desired mode using the LEFT or RIGHT button.
▶OFF : Deactivation
▶ON : DETAIL control mode (level 0~31)
When the level is up, the sharpness will increase.
Control this level to get your best picture quality.
If the level is too high, you can get an unnatural image
with video noise.
75
G) DEFAULT
: Use to reset your camera to FACTORY DEFAULT SETTING.
H) PAGE1
: PAGE 1 : Save the setting of NEXT PAGE function, and then
IP Camera User’s Manual Speco Technologies
76
IP Camera User’s Manual Speco Technologies
5.2.4. Operating WDR Camera OSD Menu (IP-WDRB1)
OSD MENU CONTROL
CENTER KEY - Used to access menu mode. Also used to confirm the setting
UP / DOWN KEY - Used to choose the desired menu selection.
LEFT / RIGHT KEY - Used to choose the desired menu feature adjustment.
OSD MENU ENTER / EXIT
A. OSD MENU ENTER
• Push Center Key for 2 seconds
B. OSD MENU EXIT
• Press EXIT Menu from Main Menu
• If Pressing Set Key for 2 seconds from Main Menu appears.
In this case, just press Set Key.
C. 'SAVE' and 'QUIT‘
• Left or Right Key - Selecting Menu
• Up or Down Key - Returning to Menu
1. Press the SET key to access the main setup mode.
2. Select the desired feature using the UP or Down key.
3. Change the status of the selected feature using the LEFT or RIGHT key.
MAIN MENU
A. PRESETS
• DEFAULT : Optimized for normal scenes
• INDOOR : Optimized for indoor scenes with windows and/or glass door to capture details both indoors
and outdoors.
• OUTDOOR : Optimized for sunny outdoor scene to capture detail both in bright areas and shadows.
• CUSTOM : Change the value of the customer.
B. SETUP ID
• DISPLAY ID
77
IP Camera User’s Manual Speco Technologies
RANGE from 0 to 36
- ON :The ID name will displayed in the monitor.
- OFF : The name will not displayed in the monitor.
• CAMERA ID : Enter up to 8 characteristic.
• ID POSITION : Select the screen position of the camera ID.
C. LENS
• DC : Use When using DC lens.
• MANUAL : Use When using Manual lens.
D. WDR
• WDR (Wide Dynamic Range) : You can adjust the desired WDR BIAS from -20 to 20 and WDR
E. WB CONTROL
• ATW (Auto Tracking White Balance) : The camera automatically control the white balance in any
environment.
• AWB (Auto White Balance) : The white balance is automatically adjusted in a specific environment.
• MANUAL : Users can adjust the colors by adding or reducing the WB level.
You can adjust the desired WB level from 2K to 11K
F. LOW LIGHT
• SLOW SHUTTER : Control Image brightness by adjusting shutter speed
You can adjust the desired shutter speed from off to X32
- AGC : ON (You can adjust the desired AGC level from 0 to 60dB) or OFF (Deactivate automatic gain
control feature)
• AUTO D/N : AUTO DAY/NIGHT
G. SPECIAL
• VIDEO : NTSC or PAL SELECTION
• FLIP : HORIZONTAL REVERSE (OFF or ON)
• SYNC
- INTERNAL : Internal synchronization
- INTERNAL2 : Internal synchronization (Color Rolling Mode)
- LINE LOCK : Phase adjustment may be necessary in multiple camera installations to prevent picture
roll
when switching between cameras
• BACK LIGHT : BACK LIGHT ADJUST or SELECT AREA
• RESOLUTION : Select Resolution of CCD or PIXIM
• COLOR MODE : COLOR or B/W SELECTION
78
IP Camera User’s Manual Speco Technologies
• SHARPNESS : ON (You can adjust the desired Sharpness form -8 to 8) or OFF
H. EXIT MENU
• EXIT NO CHANGES : No change
• SAVE NEW AND EXIT : Save change
• RESTORE FACTORY SETTINGS : Factory default
• RELEASE VERSION
I. PREVIOUS PAGE
•PREVIOUS PAGE : Return page
5.2.5. Operating Camera OSD Menu (IP-SD10X)
MAIN MENU
DOME SETUP
CAMERA SET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
* Use the the five keys on the WebViewer GUI “up down” to move the position and
“left right” to make selection
79
IP Camera User’s Manual Speco Technologies
DEFAULT SETTING
A. Dome Setup
To enter Dome setup, use the five keys right to move when cursor on dome setup.
DOME SET
CAMERA ID : CAM1□□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 100°/S
AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
A-1. DOME SET - CAMERA ID
To set camera ID, select up to 16 characters using Five keys to the left or right.
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
A-2. DOME SET - RECOVER
A-3. DOME SET - MANUAL SPEED
A-4. DOME SET - AUTO FLIP
This feature allows the dome to work from the last setting before you use the dome
manually
(Auto scan, group tour, preset, pattern or sectors) , after the set time, even power shut
down and it turns on again. Recover time can be programmed from 15 second to 99
seconds. The default setting is OFF.
Manual Speed of Pan/Tilt is selectable from 100°/sec up to 150°/sec. The default
setting is 100°/sec
Auto Flip is available and the default setting is OFF. Move five keys “right or left” to
80
IP Camera User’s Manual Speco Technologies
DEFAULT SETTING
select ON or OFF. The default setting is OFF.
A-5.DOME SET – ZOOM SPEED
Zoom speeds are selectable FAST or SLOW mode. Move five keys to the right
direction for selecting FAST or SLOW. The default setting is FAST.
A-6.DOME SET – ALARM
All alarms are available after set as ENABLE Mode. Move five keys to right or left
direction for selecting ENABLE/DISABLE. The default setting is DISABLE.
A-7.DOME SET – LANGUAGE
Multiple languages are selectable here including English, Italian and Polish. Move five
keys to the right or left direction to select language. The default setting is ENGLISH.
A-8.DOME SET – [NEXT PAGE]
DOME SET
SYSTEM LOCK: : OFF
[PASS WORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
A-8-1.DOME SET – [NEXT PAGE] – SYSTEM LOCK
Password protection provides keeping memorized data. It cannot be adjusted by
anybody without password. In order to enter [PASS WORD] page, system lock status
is must set as ON. Move five keys to right or left direction to select ON. The default
setting is OFF.
A-8-2.DOME SET – [NEXT PAGE] – [PASSWORD]
To enter this page to set a password, move five keys to the right direction. The
password must be set by preset number from 001 to 255 (Default 99)
81
IP Camera User’s Manual Speco Technologies
5.2.1. OSD MAIN MENU TABLE (PAGE 54) The default setting is BLANK.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***
Press any number from 001~255 with preset button on password blank and again it on
confirm blank. Then “CONFIRMED” is displayed on the monitor and the menu will go
back to the previous page automatically.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CONFIRMED
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CANCELLED
<CONFIRMED> <CANCELLED>
If user presses wrong preset number between PASSWORD and CONFIRM,
“CANCELLED” is displayed on the monitor and if user failed 3 times, the menu will
return to the previous page automatically * After setting a Password, an operator must
press memorized password in order to enter OSD MAIN MENU, or to change the data
which is memorized originally.
* An operator must remember the password for the operation. Manufacturer doesn’t
provide a memorized password.
A-8-3.DOME SET – [NEXT PAGE] – [OSD DISPLAY]
OSD ID displayed after set ON in here and it can be hiding if selected OFF. Move five
keys to the right or left direction in order to select OFF/ON when the cursor is located
each item.
82
DEFAULT SETTING
DEFAULT SETTING
OSD DISPLAY
CAMERA ID : OFF
PRESET ID : OFF
SECTOR ID : OFF
COORDINATE : ON
[PREVIOUS PAGE]
A-8-4.DOME SET – [NEXT PAGE] – [SYSTEM STATUS]
This page shows the information of this camera.
PROTOCOL : PELCO D, P
BAUD RATE : 2400 BPS
FIRMWARE VER. : 2.00
UPGRADED DATE : 06.07,22
CAMERA MODULE : SDM100
[PREVIOUS PAGE]
SYSTEM STATUS
IP Camera User’s Manual Speco Technologies
A-8-5.DOME SET – [NEXT PAGE] – [INITIALIZATION]
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 29, 30 and 31)
- Firmware version and upgraded date will be changed if upgraded.
- Below camera modules can be set as follows.
SDM100 : SAMSUNG 10X ZOOM CAMERA MODULE.
EN300 : OPTICAL 3X MODULE (PAN FOCUS)
: Board Camera ( with Fixed Lens)
To clear all memorized data for tour, preset, sector, privacy or pattern, move five keys to
the right direction when the cursor is on [INITIALIZATION]
- To clear memorize any data, move five keys to the right direction when cursor is on
each item.
TOUR CLEAR
ARE YOU SURE? YES NO
TOUR CLEAR
Press FOCUS NEAR button when the cursor is at YES in order to clear memorized
data. Then flickered each item such as tour, preset, sector and so on is displayed on
the monitor about 2~3 seconds. After this process, the menu is returned to the
previous page.
* [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN CLEAR] are
same as [TOUR CLEAR].
LOAD OPTIMIZED DEFAULT
ARE YOU SURE? YES NO
ALL DATA INITIALIZING
- To clear all data and wants returning to factory default, move five keys to the right
direction when cursor is at [LOAD OPTIMIZED DEFAULT] to enter the above page.
- Move five keys to the right or left direction in order to select YES, press FOCUS
NEAR button.
- Then “ALL DATA INITIALIZING” is displayed about 5~7 seconds and then the menu is
returned to the previous page automatically.
84
IP Camera User’s Manual Speco Technologies
A-9.DOME SET – [NEXT PAGE] – SAVE AND EXIT
To saving the memorized data and escape this page, move five keys to the right
direction when cursor is at SAVE AND EXIT.
A-10.DOME SET – [NEXT PAGE] – EXIT
In order not to save any data and wants to escape this page, move five keys to the right
direction when cursor is at EXIT
B. CAMERA SET
FLICKER : OFF
MIRROR : OFF
APERTURE : 10
D ZOOM : OFF
WB MODE : AWB MODE
PIC FLIP : OFF
BLC : OFF
D/N MODE : AUTO
DSS MODE : OFF
EXIT
CAMERA SET
FLICKER : OFF
BLC : OFF
EXIT
CAMERA SET
<TS-PTZ10X> < TS-PTZ3X >
B-1.CAMERA SET - FLICKERLESS
Flickerless feature is selected between 50Hz and 60Hz. The default setting is OFF
(NTSC: 60Hz / PAL: 50Hz). Set flicker mode ON when power source is in discord with
frequency. The default setting is OFF
B-2.CAMERA SET - MIRROR
This feature shows left and right exchanged picture image like mirror. The default
setting is OFF.
(10X Zoom)
85
IP Camera User’s Manual Speco Technologies
B-3.CAMERA SET – APERTURE
Aperture enhances picture details by increasing gain of the caemra and sharpens the
edges in the picture. The default seeting is 10. (the aperture level is from 01 ~ 15)
(10X Zoom)
B-4.CAMERA SET – D ZOOM
Move five keys to the right direction in order to set as ON, if Digital Zoom is necessary
at install field. The default setting is OFF.
(10X Zoom)
B-5. CAMERA SET – WB MODE
White balance functions have 4 modes according to the condition of exterior lighting.
The default setting is AWB and it may change the mode option accoding to the lighting
conditions as below.
AWB Mode – 3,200°K to 6, 000°K (10X Zoom)
Indoor – up to 3,200°K
Outdoor – up to 5,800°K
ATW Mode - 2,000°K to 10, 000°K
B-6.CAMERA SET – PIC FLIP
Picture flip feature provides the top and down exchanged picture image horizontally.
Move five keys to the right or left direction to select OFF/ON. The default setting is
OFF.
(10X Zoom)
B-7. CAMERA SET – BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
OFF – Backlight compensation is not activated.
ON – Back light compensation is activated.
B-8. CAMERA SET – D/N MODE
ICR filter is changeable according to the lighting, AUTO – NIGHT MODE – DAY MODE.
The default setting is AUTO MODE.
86
IP Camera User’s Manual Speco Technologies
DEFAULT SETTING
(10X Zoom)
B-9. CAMERA SET – DSS MODE (DIGITAL SLOW SHUTTER)
If DSS turns on, digital slow shutter is working. Per second, the electronic shutter will
remain open to receive some more lighting.
(10X Zoom)
B-10. CAMERA SET – EXIT
To escape this page, move five keys to the right direction.
C. PRESET SET
To enter PRESET SET, move five keys to the right direction.
PRESET NO :001
PRESET ID :PRESET001------PAN :XXX.XX TILT : XXX.XX
SAVE
EXIT
C-1. PRESET – PRESET NO.
C-2. PRESET – PRESET ID
PRESET SET
Up to 165 numbers of preset positions are available. Move five keys to the right or left
direction to select preset no.
To set preset ID, select up to 16 characters using Five keys to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right
direction and ZOOM WIDE button moves to the next character from the right to left
direction
(Space displays when appears)
87
IP Camera User’s Manual Speco Technologies
SAVE AND EXIT
DEFAULT SETTING
C-3. PRESET – PAN: XXX.X TILT: XX.X
Press FOCUS FAR button in order to set preset position then, use the five keys to the
position where memorized preset no. is needed. Then press FOCUS FAR button again
after setting a preset location.
C-4.PRESET – SAVE
Move five keys to the right direction when the cursor is at SAVE and then the cursor will
be located on Preset ID for the continuous preset No. setting.
C-5. PRESET – EXIT
To escape this page, move five keys to the right direction.
D. AUTO SCAN SET
START ANGLE :
XXX.X.XX.X
END ANGLE :
XXX.X.XX.X
DIRECTION : CW
ENDLES : OFF
SPEED : 10°/S
DWELL TIME : 03
D-1. AUTO SCAN- START ANGLE
To set start angle, press FOCUS FAR button then move five keys to the starting angle
which is needed memorized. To press FOCUS FAR button again is to escape.
D-2. AUTO SCAN- END ANGLE
To set end angle, press FOCUS FAR button then move five keys to the starting angle
which is needed memorized. To press FOCUS FAR button again is to escape.
D-3. AUTO SCAN – DIRECTION
Auto Scan directions are available with two direction as CW or CCW by five keys to the
AUTO SCAN SET
88
IP Camera User’s Manual Speco Technologies
right or left direction
CW: Clock wise direction (Default)
CCW: Count Clock Wise Direction.
D-4. AUTO SCAN – ENDLESS
Auto Scan can use endless rotation, move five keys to the right direction in order to
select ON. Otherwise, the default setting is OFF.
D-5. AUTO SCAN – SPEED
User can use auto scan speed from 05°/S up to 35°/S and the default setting is 10°/S
D-6. AUTO SCAN – DWELL TIME
To select dwell time, move five keys to the left or right direction in order to adjust dwell
time. Possible to set from 01 second to 30 seconds and the default setting is 03
seconds.
D-7. AUTO SCAN – SAVE AND EXIT
To saving the memorized data and escape this page, move five keys to the right
direction when cursor is at SAVE AND EXIT.
D-8. AUTO SCAN – EXIT
To escape this page, move five keys to the right direction.
89
IP Camera User’s Manual Speco Technologies
EXIT
DEFAULT SETTING
E. TOUR SET
8 Programmable tours can be set and each tour is available to set up to 64 preset steps.
TOUR NO : 01
TOUR TITLE : TOUR01□□□□□□□□□□
TOUR STEP : 01
PRESET NO. : 01
DWELL TIME : 03
SPEED : 200°/S
SAVE
E-1. TOUR SET – TOUR NO.
Max. 8 group tour no. set by the five keys are available.
E-2. TOUR SET – TOUR TITLE
To set tour title, select up to 16 characters using Five keys to left or right.
Press ZOOM TELE button to move the next character from the left to the right direction
and ZOOM WIDE button to move the next character from the right to left direction
(Space displays when appears) Tour title is not displayed on the monitor, but only
for the reference of user.
E-3. TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed. It
is possible to match any preset # for each tour step.
E-4. TOUR SET – PRESET NO.
The decided tour step #1 ~64, it is possible to select any preset no. up to 64. The
default setting is BLK
E-5. TOUR SET – DWELL TIME
Dwell time provides up to 99 seconds from 01 second. The default setting is 03
seconds.
TOUR SET
90
IP Camera User’s Manual Speco Technologies
DEFAULT SETTING
E-6. TOUR SET – SPEED
Each tour step can be set with different tour speed up to 200°/S and it is selectable
from 10°/S. Move five keys to the right or left direction to select tour speed. The
default setting is 200°/S.
E-7. TOUR SET – SAVE
To save the memorized data and escape this page, move five keys to the right direction
when cursor is at SAVE
E-8. TOUR SET – EXIT
To escape this page, move five keys to the right direction
F. PRIVACY SET
Privacy function is provided by (10X Zoom) only.
4 Privacy masking zones are available to block out areas of security.
PRIVACY NO : 01
DISPLAY : OFF
ACTION : MOVE
SAVE
EXIT
F-1. PRIVACY SET – PRIVACY NO.
Up to 4 privacy masking zones are available.
F-2. PRIVACY SET – DISPLAY
Move five keys to the right or left direction to set ON in order to show the selectable
block in the center of the monitor. This block appears as a translucent square with
blue color after set ON. The default setting is OFF.
F-3. PRIVACY SET – ACTION(MOVE/ADJUST)
PRIVACY SET
91
IP Camera User’s Manual Speco Technologies
DEFAULT SETTING
To set the blocking area, press FOCUS FAR button when the MOVE MODE is
appeared. Then use the five keys to the user defined area in order to set blocking
area. Then press FOCUS FAR button again to escape from MOVE MODE.
To adjust size of blocking area, move five keys to the right or left direction when the
cursor is on ACTION. After move mode changed to ADJUST MODE, press FOCUS
FAR button in order to adjust the size of blocking area. The size of blocking area can
be adjustable by using five keys up down or left right,. After adjusting size of blocking
area, press FOCUS FAR button to escape ADJUST mode.
ADJUST: You can change the masking size by using five keys to the left or right
direction
MOVE: You can move the masking area by using five keys to the left or right
direction (Default)
F-4. PRIVACY SET – SAVE
After setting the privacy masking zone, to save the data, move five keys to the right
direction when the cursor is on SAVE. After saving the data, the cursor moves to
PRIVACY NO.2 automatically to prepare the next privacy masking zone.
F-5. PRIVACY SET – EXIT
To escape this page, move five keys to the right direction
G. PATTERN SET
8 programmable patterns are available with 16 characters of title.
PATT NO : 01
PATT TITLE: PATTERN01□□□□□□□
DATA FILL : 100%
SAVE
EXIT
G-1. PATTERN SET – PATT NO.
PATTERN SET
92
IP Camera User’s Manual Speco Technologies
Up to 8 programmable user-defined patterns set by the five keys on the Webviewer
GUI are available.
G-2. PATTERN SET – PATT TITLE
To set PATTERN TITLE, select up to 16 characters using Five keys to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right
direction and ZOOM WIDE button moves to the next character from the right to left
direction (Space displays when appears) Pattern title is not displayed on the monitor,
but only for the reference of user.
G-3. PATTERN SET – DATA FILL
To fill the programming data, press FOCUS FAR button in order to start the data fill up.
Filling data is programmed according to the the five keys on the Webviewer GUI
movement. Press FOCUS FAR button again in order to escape.
G-4. PATTERN SET – SAVE
To saving the filling data, move five keys to the right direction when the cursor is on
SAVE. Then the cursor moves to the PATT NO.02 in order to prepare next pattern no.
G-5. PATTERN SET – EXIT
To escape this page, move five keys to the right direction
93
H. ALARM SET
DEFAULT SETTING
4 Alarm inputs are available and each alarm is activating to presets, group tours or
patterns.
IP Camera User’s Manual Speco Technologies
ALARM NO : 01
ALARM INPUT: OFF
ALARM ACT : 001
SAVE
EXIT
ALARM SET
H-1. ALARAM SET – ALARM NO.
Up to 4 alarms are selectable by using five keys to the right direction when cursor is
on ALARM NO.
H-2. ALARAM SET – ALARM INPUT
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal
Close)
The default setting is OFF
H-3. ALARAM SET – ALARM ACT
Alarm activates various surveillance modes with Preset number up to 165, Group
tour up to 8, Pattern up to 8. Move five keys to the right or left direction to select any
preset number, group tour no. or pattern no.
H-4. ALARAM SET – SAVE
After setting the alarm input ways and activation, to save the data, move five keys to
the right direction when the cursor is on SAVE. After saving the data, the cursor moves
to Alarm NO.2 automatically to prepare the next alarm.
H-5. ALARAM SET – EXIT
To escape this page, move five keys to the right direction
94
IP Camera User’s Manual Speco Technologies
* Before activating Alarm, user must set ALARM ENABLE at DOME SET – ALARM –
ENABLE (Refer to page 15)
I. SECTOR SET
Up to 8 programmable sectors are available with 16 characters.
This feature is useful to memory the certain location such as parking zone or so on.
When camera goes through this area, it shows the letter you memorized.
SECTOR NO : 01
SECTOR ID : SECTOR01□□□□□□□□
SECTOR START: XXX.X.XX.X
SECTOR END : XXX.X.XX.X
SAVE
EXIT
I-1. SECTOR SET – SECTOR NO.
I-2. SECTOR SET – SECTOR ID
I-3. SECTOR SET – SECTOR START
SECTOR SET
Start Position
End Position
DEFAULT SETTING
Up to 8 programmable sectors set by the five keys are available.
set SECTOR ID, select up to 16 characters by using five keys to the left or right.
Press ZOOM TELE button to move to the next character from the left to the right
direction and ZOOM WIDE button to move to the next character from the right to left
direction (Space displays when appears)
To set SECTOR START angle, press FOCUS FAR button then move five keys to the
left or right direction to set the position. To press FOCUS FAR button again is to
escape.
95
IP Camera User’s Manual Speco Technologies
I-4. SECTOR SET – SECTOR END
To set SECTOR END angle, press FOCUS FAR button then move five keys to the left
or right direction to set the position. To press FOCUS FAR button again is to escape.
I-5. SECTOR SET – SAVE
After setting the SECTOR position, to save the data, move five keys to the right
direction when the cursor is on SAVE. After saving the data, the cursor moves to
SECTOR NO.2 automatically to prepare the next SECTOR.
I-6. SECTOR SET – EXIT
To escape this page, move five keys to the right direction
J. EXIT
To escape OSD Main Menu, move five keys to the right or left direction then this
camera is ready to operate.
96
IP Camera User’s Manual Speco Technologies
5.2.6. DIP SW SETTING
Mini Speed Dome camera provides up to 63 camera ID and it’s adjustable ID with 1st~6th of
Dip switch
Open the camera case, set ID using DIP SW1.
* Factory default: Camera ID = 1, PELCO-D
5.2.7.ID SETTING(1-ON, 0-OFF)(110)
DIP SW ID VALUE
100000XXXX
010000XXXX
110000XXXX
001000XXXX
101000XXXX
011000XXXX
111000XXXX
000100XXXX
100100XXXX
010100XXXX
110100XXXX
001100XXXX
101100XXXX
011100XXXX
111100XXXX
000010XXXX
1 111010XXXX 23 101101XXXX 45
2 000110XXXX 24 011101XXXX 46
3 100110XXXX 25 111101XXXX 47
4 010110XXXX 26 100011XXXX 48
5 110110XXXX 27 100011XXXX 49
6 001110XXXX 28 010011XXXX 50
7 101110XXXX 29 110011XXXX 51
8 011110XXXX 30 001011XXXX 52
9 111110XXXX 31 101011XXXX 53
10 000001XXXX
11 100001XXXX
12 010001XXXX
13 110001XXXX 35 100111XXXX 57
14 001001XXXX
15 101001XXXX
16 011001XXXX 38 001111XXXX 60
DIP SW ID VALUE
32 011011XXXX 54
33 111011XXXX 55
34 000111XXXX 56
36 010111XXXX 58
37 110111XXXX 59
97
DIP SW ID VALUE
100010XXXX
010010XXXX
110010XXXX
001010XXXX
101010XXXX
011010XXXX
17 111001XXXX 39 101111XXXX 61
18 000101XXXX
19 100101XXXX
20 010101XXXX
21 110101XXXX 43
22 001101XXXX 44
40 011111XXXX 62
41 111111XXXX 63
42
5.2.8. PROTOCOL
7th~8th dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P ( Auto detection)
DIP SW1- 7 DIP SW1- 8
OFF OFF Pelco-D or Pelco-P
5.2.9. BAUD RATE SETTING
The 9th Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps.
DIP SW1 9th BAUD RATE
OFF 2400
ON 9600
98
IP Camera User’s Manual Speco Technologies
5.3. Use of IP Setting Utility
Upon running IP Setting Utility, the following program is to be displayed.
Fig. 5―2 IP Find
Click ‘IP Find’ Button to find IP of THE CAMERA on local Network.
IP Camera User’s Manual Speco Technologies
Fig. 5―3 Display IP
The following window shows list of IP along with Web Server Port Number and Model Name of THE
CAMERA. Click ‘IP Find’ Button to find IP of THE CAMERA on local Network.
99
IP Camera User’s Manual Speco Technologies
Fig. 5―4 IP Check
After finding IP, double-click IP of THE CAMERA to go to the editable Mode as follows.
Fig. 5―5 IP Check
Input new IP Address, Default Gateway, Subnet Mask, and then input Password of THE CAMERA
Administrator and click ‘IP Change’, to set up new IP of THE CAMERA. Upon completion of setting,
find new IP and click ‘Ping’ to check whether setting is done, and close the program by clicking
‘End’ button.
100
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.