Spears PD-400-001C-10, PD-400-002C-10, PD-400-003C-10, PD-400-005C-10, PD-400-007C-10 User Manual

...
Schedule 80 CPVC Pipe Dimensions & Pressure Ratings
Schedule 80 CPVC Pipe
Nom. Pipe
Size (in)
1/4 .540 .282 0.119 0.117 1130
3/8 .675 .403 0.126 0.163 920 1/2 .840 .526 0.147 0.225 850
3/4 1.050 .722 0.154 0.304 690
1 1.315 .936 0.179 0.449 630
1-1/4 1.660 1.255 0.191 0.617 520
1-1/2 1.900 1.476 0.200 0.751 470
2 2.375 1.913 0.218 1.040 400
2-1/2 2.875 2.290 0.276 1.582 420
3 3.500 2.864 0.300 2.121 370
3-1/2 4.000 3.326 0.318 2.735 350
4 4.500 3.786 0.337 3.2101 320 5 5.563 4.768 0.375 4.800 290
6 6.625 5.709 0.432 6.200 280
8 8.625 7.565 0.500 9.042 250 10 10.750 9.493 0.593 13.018 230
12 12.750 11.294 0.687 18.350 230
14 14.000 12.410 0.750 23.260 220 16 16.000 14.213 0.843 29.892 220
18 18.000 16.014 0.937 35.421 220 20 20.000 17.814 1.031 45.879 220
24 24.000 21.418 1.218 64.958 210
Average O.D. Average I.D. Min. Wall Nominal Wt./Ft.
Schedule 80 CPVC Technical
Maximum.
W.P. PSI*
Maximum CPVC Service Temperature 200°F
Pressure De-rating at Elevated Temperatures
The pressure ratings given above are for water, non-shock, @ 73°F. The specified derating factors for CPVC are suitable for pipe conveying water at elevated temperatures. To determine elevated temperature rating, multiply 73°F [23°C] pressure rating by appropriate factor shown in the table for desired operating temperature. When working near maximum specified temperature, solvent cement joints are recommended in place of threaded connections. Where disassembly is required at elevated
®
temperatures, use Spears unions or grooved coupling connections. Spears
Special reinforced (SR) adapters, flanges,
®
recommends that only
Schedule 80 or heavier wall thickness pipe should be threaded.
See Plastic Pipe Engineering Guide for additional information
CPVC Pipe
Operating Temp (°F) De-Rating Factor
73 1.00 90 0.91
100 0.82
110 0.72
120 0.65
130 0.57
140 0.50
150 0.42
160 0.40 170 0.29
180 0.25
200 0.20
EX: 2" CPVC SCHEDULE 80 @
120°F = 400 psi x 0.65 = 260 psi max. @ 120°F
Made in the U.S.A.
Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas
See Spears® Product Sourcebook for product offerings
Page 54
Schedule 80 CPVC Pipe Dimensions & Pressure Ratings
Pipe - CPVC Schedule 40 Plain End
10' Lengths
Schedule 80 CPVC Technical
Part Number Size L AVG.O.D.
PD-400-001C-10 1/8 10 .405 .068 .09 PD-400-002C-10 1/4 10 .540 .088 .09 PD-400-003C-10 3/8 10 .675 .091 .12 PD-400-005C-10 1/2 10 .840 .109 .18 PD-400-007C-10 3/4 10 1.050 .113 .23 PD-400-010C-10 1 10 1.315 .133 .35 PD-400-012C-10 1-1/4 10 1.660 .140 .47 PD-400-015C-10 1-1/2 10 1.900 .145 .56 PD-400-020C-10 2 10 2.375 .154 .77 PD-400-025C-10 2-1/2 10 2.875 .203 1.20 PD-400-030C-10 3 10 3.500 .216 1.57 PD-400-040C-10 4 10 4.500 .237 2.23 PD-400-050C-10 5 10 5.563 .258 2.87 PD-400-060C-10 6 10 6.625 .280 3.94 PD-400-080C-10 8 10 8.625 .322 5.95 PD-400-100C-10 10 10 10.750 .365 8.53 PD-400-120C-10 12 10 12.750 .406 10.83 PD-400-140C-10 14 10 14 .437 13.26 PD-400-160C-10 16 10 16 .500 18.16 PD-400-180C-10 18 10 18 .562 22.27 PD-400-200C-10 20 10 20 .593 26.46 PD-400-240C-10 24 10 24 .687 38.36
Minimum
Wall
Pipe - CPVC Schedule 40 Plain End
20' Lengths
Approx. Wt.
(Lbs./Ft)
Part Number Size L AVG.O.D.
PD-400-001C 1/8 20 .405 .068 .09 PD-400-002C 1/4 20 .540 .088 .09 PD-400-003C 3/8 20 .675 .091 .12 PD-400-005C 1/2 20 .840 .109 .18 PD-400-007C 3/4 20 1.050 .113 .23 PD-400-010C 1 20 1.315 .133 .35 PD-400-012C 1-1/4 20 1.660 .140 .47 PD-400-015C 1-1/2 20 1.900 .145 .56 PD-400-020C 2 20 2.375 .154 .77
Page 55
Suitable for Oil-Free air handling to 25 psi, not for distribution of compressed air or gas
See Spears® Product Sourcebook for product offerings
Minimum
Wall
Approx. Wt.
(Lbs./Ft)
Spears® Manufacturing Company
Loading...