Speakman SPK3339 Specifications

Page 1
®
SPEAKMAN
Optimus™ Combination Shower and Eye And Face Wash System
EYEWASH FEATURES
• Independent eye wash & face wash integrated into one, multi-functioning safety unit.
• Aerated sprays for eyewash comfort & innovative face pads for full face cleansing
• Stainless steel eye and face wash unit
• Flip top dust caps
• Stainless Steel eye and face wash unit
• ½ in. NPT female stainless steel, chrome-plated, full ow stay-open ball valve
• Stainless steel push handle activator
• ½ in. NPT female inlet
• 4.9 gpm @ 30 psi
SHOWER FEATURES
• 8 in. stainless steel showerhead
• Internal 20 gpm restrictor ow control
• 1 in. NPT female stainless steel, chrome-plated, full ow stay-open ball valve
• Powder coated yellow, aluminum triangular pull rod activator & optimal ADA extension
• 1¼ in. IPS stainless steel piping stanchion & ttings
• 1¼ in. NPTF top or side supply
• 1¼ in. NPT female waste
• High visibility pull rod activates stay-open shower valve & provides hands-free operation
• Elevated drain to support easier testing and to eliminate trip hazards
• Includes all components necessary to be installed in either standard height or ADA conguration
• 20 gpm @ 30 psi
• Patent Pending
• Universal Emergency Sign Included
SE-1255
SPECIFICATION
COMPLIANCE:
• ANSI/ISEA Z358.1
• Wheelchair accessible when installed accordingly
OPTIONS:
ADD SUFFIX TO MODEL #
• Anti-freeze protection valve ❑ -FPV
• Hand & foot operation ❑ -HFO
• Hand-held spray ❑ -HS
• In-line strainer ❑ -ILS
• Full bowl cover ❑ -OCV
.• P-trap ❑ -PT
• Scald protection valve ❑ -SPV
WARRANTY:
• 3 year limited
SEE REVERSE FOR ROUGH-IN DIMENSIONS
THIS SPACE FOR ARCHITECT/ENGINEER APPROVAL.
400 ANCHOR MILL ROAD | NEW CASTLE, DE 19720 P: 800-537-2107 | F: 800-977-2747 WWW.SPEAKMANCOMPANY.COM
REVISION DATE: OCTOBER 2014
Management Systems
595
Page 2
®
SPEAKMAN
Optimus™ Combination Shower and Eye And Face Wash System SE-1255
SPECIFICATION
1
"
2
13mm
(TYP. 3 PLACES EQUALLY
SPACED 120º APART)
FLOOR FLANGE DETAIL
14
5
"±1"
62
8
1592mm±25
STANDARD INSTALLATION ROUGH-IN DIMENSIONS
7
"
7
8
200mm
15
"±
16
380mm±5
3
"
16
4
116mm±5
1 2
"±.19
9
250mm±5
5
"±1"
91
8
2329mm±25
3
13
"±
"
16
16
84"±1"
2134mm±25
41
1046mm±13
1
1
"±
"
2
8
33
840mm±10
31
806mm±16
203mm±2
8
225mm±10
3
1
"±
8
8
3
"±
4
27
705mm±19
8"±
16
7
"±
8
"
1
5 8
"
3 4
"
3 8
3
"±
4
"
19
486mm±9
"
11
1
"±
"
32
8
1-1/4 NPT FEMALE OUTLET
2
69.85mm
1-1/4" NPT (TOP) FEMALE INLET
1-1/4" NPT FEMALE INLET
35"±
890mm±10
3
"
4
3
"
8
65"±
1651mm±16
5
"
8
1
"
2
13mm
(TYP. 3 PLACES EQUALLY
SPACED 120º APART)
FLOOR FLANGE DETAIL
3
"±1"
46
16
1172.82mm±25
ADA INSTALLATION ROUGH-IN DIMENSIONS
7
"
7
8
200mm
3
29
"±
"
14
16
32
378.58mm±5
9
4
16
115.57mm±5
THIS SPACE FOR ARCHITECT/ENGINEER APPROVAL.
9
249.10mm±5
3
"±
16
3
"
31
4
806.32mm
3
"
27
4
704.72mm
1
"
8"±
16
203.20mm±2
23
"±1"
91
32
2329.92mm±25
84"±1"
2133.98mm±25
3
13
"±
"
16
16
"
11
"±
35
16
906.67mm±13
NOTE: 1. All dimensions are in inches (millimeters) unless otherwise specified and are subject to change without notice.
1 2
"
27
689.67mm±10
8"±
203.53mm±10
3
5
"±
8
32
3
"
8
"
1
19
8
485.91mm±9
1-1/4" NPT FEMALE OUTLET
3
2
4
69.85mm
1-1/4" NPT (TOP) FEMALE INLET
1-1/4" NPT FEMALE INLET
11
"±
"
32
3
3
"±
29
8
32
738.95mm±10
"
"
65"±
1651±16
5
"
8
596
400 ANCHOR MILL ROAD | NEW CASTLE, DE 19720 P: 800-537-2107 | F: 800-977-2747