SpeakerCraft RSA-1.0 Installation Instructions Manual

Page 1
INSTALLATION INSTRUCTIONS
RSA-1.0
Remote Serial Adaptor
Page 2
RSA-1.0 Installation Instructions Page 2
INTRODUCTION
The SpeakerCraft RSA-1.0 Remote Serial Adaptor provides control of RS232 compatible devices from SpeakerCraft MZC-66 and MZC-88 A/V Amplifi er/Controllers. It connects to an MZC rear panel Expansion Terminal and is triggered by EZ-Pad Button presses or remote EZ-Code IR commands (when used to control an MZC-66 or 88). The RS232 Commands are programmed into MZC Projects using EZ-Tools Programming Software. RS232 commands are stored in the EZ-Tools Command Library and programmed to keypad buttons using a similar procedure to programming IR commands. New RS232 commands, of up to 100 characters each, can be added to the Library in EZ-Tools via ASCII or HEX data entry.
Up to 16 RSA-1.0s can be used in a single system by setting each RSA to a unique device Address. A data buss can be created to ‘daisy chain’ the RSAs for ease of installation and connection.
RSA-1.0 FEATURES
1. RS232 DATA I/O - DB9M terminal connects to the de-
vice being controlled via RS232 using a DB9 cable.
2. ADDRESS SWITCH - 16 position rotary switch, sets de-
vice address allowing up to 16 RSA’s to be used in a single system.
3. 12VDC POWER JACK - 2.1mm coaxial jack connects to
a SpeakerCraft PS-1.0 Power Supply for power.
4. PROGRAMMING SWITCH - Two-position switch gets set
to ON position for updating the fi rmware from EZ-Tools.
5. IR HI/LO SWITCH - Two-position switch sets the IR
IN level. Set to HI when connected to a high IR output
2.125“
ASW1
Rear View
12 3
Top
RS232
D4
DATA I/O
J1
J5
IR
IN
6
ASW1
5
4
3
ADDRESS
RSA-1.0
RS232 Interface Adapter
9
8
A
7
B
SpeakerCraft
C
D
E
2
F
1
0
J2
EXPANSION
PORT LOOP
J3
PROGRAMMING
OFF ON
SW1:1
12V DC
J6
®
SW1:1
HI LO
IR
J4
CONTROL
PORT
4 5
D5
device, (12V; P-P) set to LO when connected to a low output device, (5V; P-P).
6. POWER LED - Red LED illuminates when RSA has DC
power and completes its internal initialization.
ASW1
ACTIVITY
1“
67891011
SW1:1
POWER
7. CONTROL PORT - 4-circuit, 3.5mm mini-jack connects to
PC running EZ-Tools for RSA programming and fi rmware updates.
Front
4.3”
Figure 1 RSA-1.0 Features
8. EXPANSION LOOP - RJ45 jack primarily used to connect to the Expansion Port on additional RSA-1.0(s) when mul­tiple RSA-1.0’s are used to control multiple RS232 devices in a single system. The Expansion Loop and Expansion Port jacks are parallel. Up to 16 RSA-1.0’s can be used in a single system.
9. EXPANSION PORT - RJ45 jack primarily used to connect to the Expansion Port or Loop on a SpeakerCraft MZC-66 or MZC-88. This connection receives control data from the MZC via RS485. RS232 commands are confi gured in the MZC using EZ-Tools.
10. IR IN - 3.5mm mini jack receives SpeakerCraft EZ-Code IR commands from an IR control system. These commands are converted to RS232 commands as associated in EZ-Tools. This jack only functions when the special IR to RS232 Control Interfacing Firmware has been programmed into the RSA.
11. ACTIVITY INDICATOR - Green LED fl ashes to indicate activation of internal command data.
Page 3
RSA-1.0 Installation Instructions Page 3
RS232
J1
J5
IR
IN
To RS232
Controlled
Device
1
0
2
F
3
E
4
ASW1
5
D
6
C
7
B
8
A
9
J2
ADDRESS
PORT LOOP
EXPANSION
J3
U5
U3
12V DC
®
PROGRAMMING
OFF ON
HI LO
CONTROL
U2
RSA-1.0
RS232 Interface Adapter
U4
SpeakerCraft
J6
SW1:1
IR
J4
PORT
U1
D5
PS-1.0 200mA Power Supply
DB9
Cable
U6
D4
Controller
RS232
DATA I/O
J1
U7
J5
IR
IN
MZC-66
or
MZC-88
To RS232
Controlled
Device
1
0
2
F
3
E
4
ASW1
5
D
6
C
7
B
8
A
9
J2
ADDRESS
PORT LOOP
EXPANSION
U2
U5
RSA-1.0
RS232 Interface Adapter
U4
U3
SpeakerCraft
RJ45
RS485
Interface
Cables
J3
PROGRAMMING
OFF ON
HI LO
CONTROL
12V DC
J6
®
SW1:1
PORT
U1
IR
J4
PS-1.0 200mA
Power Supply
D5
U6
D4
DB9
Cable
U7
DATA I/O
Figure 2 Typical RSA-1.0 Application
INSTALLATION
When all system components are installed in a central equipment rack or closet, the RSA-1.0(s) should be mounted in a place that provides easy access should reprogramming or service be necessary. The plastic fl ange extensions and mounting holes allow vertical installation on a cabinet side or equipment room wall.
The CAT-5 connections between an MZC-66/88 and a RSA-1.0 are RS485 protocol, so the runs can be fairly long. Typical RS-485 TX/RX, (transmit/receive) allows up to 1000 feet between devices. When using multiple RSA’s, the TOTAL cable length from the MZC to the LAST RSA should not exceed this specifi cation.
The DB9 connections between the RSA-1.0(s) and the device(s) being controlled are RS232 protocol which has a limitation of about 50 feet between devices. For best performance try to install the RSA-1.0(s) as close to the device(s) being controlled as possible.
When using multiple RSA’s, it is recommended that each be labeled with the device brand, type (DVD player, Server, etc) and model number to assist in servicing and troubleshooting the system when necessary.
CONNECTIONS NOTE: The RSA-1.0 has a DTE pinout. If the device being controlled has a DCE pinout, a pass-through cable, (pin to
pin), should be used. If the device being controlled also has a DTE pinout, then a Null Modem Cable should be used.
1. Using a properly terminated CAT-5 cable (pass-through, pin to pin confi guration) connect the Expansion Loop on a SpeakerCraft MZC-66/88 to the Expansion Port on a RSA-1.0. (Refer to Figure 2)
2. Using a properly confi gured DB9 cable to connect the RS 232 DATA I/O Port on the RSA-1.0 to an appropriate RS 232 Data I/O Port on the device being controlled. (Refer to Figure 2)
3. If using multiple RSA-1.0’s using a properly terminated CAT-5 cable (pass-through, pin to pin confi guration) connect the Expansion Loop on a RSA-1.0 to the Expansion Port on the next RSA-1.0. (Refer to Figure 2)
4. Using properly confi gured DB9 cables (pass-through, pin to pin confi guration) connect the RS 232 DATA I/O Ports on the RSA-1.0’s to the appropriate RS 232 Data I/O Ports on the devices being controlled. (Refer to Figure 2)
5. When all other connections have been made and the system is ready for programming/operation, connect a SpeakerCraft PSA-1.0 12VDC 200mA Power Supply to the 12VDC Power Jack on each RSA-1.0. (Refer to Figure
2)
Page 4
RSA-1.0 Installation Instructions Page 4
CONFIGURATION
Confi guring a single RSA-1.0 application is simple. Set the Address Switch to ‘0’. (Be sure to select Address ‘0’ when Adding An Expansion Device in EZ-Tools Setup.)
Confi guring multiple RSA-1.0s is similar in a way to routed infrared. With routed IR, when a button is pressed on a keypad or remote, to control for example a specifi c Satellite Receiver in a system with multiple Satellite Receivers, the IR command is routed by the Control System to the specifi c IR output for that Satellite Receiver, allowing selective control of multiple same­brand, same-model devices. The same is true when using multiple RSA-1.0’s. When a button is pressed on a keypad or remote (specifi cally programmed to control a MZC-66/88) the Control System (MZC-66/88) will output a control command via the Expansion Loop that will ‘look’ for a specifi c RSA Address. When an RSA with the proper Address is located, that RSA will interpret the incoming control command and output the appropriate RS232 command to the device being controlled. All other RSA’s on the Expansion Loop Bus, set to a different Address will ignore the command. This allows selective RS232 control of multiple same-brand, same-model devices or control of a variety of devices from different manufacturers.
1. When using one RSA-1.0, set the Address Switch to ‘0’.
2. When using multiple RSA-1.0’s set the Address Switch on each RSA-1.0 to a different address. Up to 16 different addresses can be confi gured.
When using multiple RSA-1.0’s keep a written record of each RSA’s Address Switch setting and the device it is intended to
control. This information will be critical during programming.
PROGRAMMING
The initial release of the RSA-1.0 will only allow programming and interfacing with SpeakerCraft MZC-66/88 Multi-Zone Controllers. The following Programming Instructions detail the steps required to program a RSA-1.0 for use with MZC-66/88. Please visit the SpeakerCraft web site, www.speakercraft.com for updates on additional uses of this product, including IR to RS232 control interfacing.
Programming an RSA-1.0 for use in a MZC System is similar to the normal programming procedure for associating System commands in Events Setup or confi guring Source Commands in Zone Setup. For Events Setup, the RSA RS232 commands can be associated with a System Turning ON, System Turning OFF, Zone Turning ON, Zone Turning OFF or Doorbell Event in the same way that MZC Commands or Source IR commands are programmed. In Zone Setup, RSA RS232 commands can be confi gured to be output from the MZC when initiated by a keypad button press as a single command or part of a macro. Programming an RSA-1.0 does require that RS232 commands have been stored in the CMD Library by Brand, Component and Model. See Section: Creating RS232 Commands for additional information. To program a MZC Project using an RSA-1.0 with existing RS232 commands:
1. Open an existing or create a new EZ-Tools Project for MZC-66/88.
2. Left click the Project Content Tab so MZC-66/88 Stand- alone is highlighted. (In expanded systems with multiple MZC’s, MZC-66/88 Master should be highlighted.)
3. Right Click MZC Standalone/Master. Highlight Add Expansion Device in the pop-up window.
4. Left Click RSA-1.0 in the second pop-up window. (Refer to Figure 3) The Expansion Device Setup Window will appear. NOTE: An RSA-1.0 can also be added by right clicking the Expansion Devices icon at the bottom of the Project Content Window. Right click Expansion Devices, roll the mouse over the pop-up and left click RSA-1.0.
Figure 3 Adding an RSA-1.0 to a MZC Project
Page 5
RSA-1.0 Installation Instructions Page 5
5. Select an Address from the Address pull-down. (Refer to Figure 4) If using only one RSA-1.0 use the default of ‘0’. If using multiple RSA-1.0’s, set each to a different address.
6. Left click OK in the Expansion Device Setup Window to set the Address. An RSA-1.0 icon will appear at the bottom of the Project Content Window under Expansion Devices as RSA-1.0-0 (assuming Address ‘0’ was selected). If mul­tiple RSA-1.0s are added, they will all appear and each will indicate its Address, RSA-1.0-0; RSA-1.0-1; RSA-1.0-2; etc. as shown in Figure 5.
7. In the Project Content Window, left click the EZ-Pad in the Zone that is going to be programmed to send RS232 commands from the RSA-1.0. (Zone 1, EZ-Pad-0 as shown in Figure 6.) The EZ-Pad selected will appear on screen.
8. Left click the button on the EZ-Pad that is going to be programmed to send RS232 commands via the RSA-1.0. The button will highlight in blue, and the Button Proper­ties Window will appear, if not already on screen.
9. In the Project Content Window, left click the RSA-1.0 that is going to control the device selected on the EZ-Pad in Step 8 above, (in this case AUX, which is an Escient FireBall). The word SELECTED will appear after the RSA-
1.0 icon to indicate that the RSA has been selected for programming. If multiple RSAs are being used in a system, this will indicate which RSA has been selected.
10. Left click the CMD Library Tab to bring the IR/RS232 Com­mand Library to the front.
11. In the Brands text box, type in the name of the brand to be programmed, in this case Escient. (The pull-down can also be used as well as typing in ‘E’ and scrolling to Escient from the beginning of the ‘E’s’ using the arrow down key.)
Figure 4 Selecting an RSA-1.0 Address
Figure 5 Multiple RSA-1.0 Addresses
12. Double left click the type of component being controlled, DVD player, CD changer, etc. or in this case, Music Server. If a single model is available under the component se­lected, the sub-directory will open a list of commands. If multiple model numbers are available, double left click the model number for the device being controlled to open the command list.
13. Scroll through the list to fi nd the RS232 Commands. RS232 Commands are ‘prefi xed’ with a blue ‘1010’. If no RS232 commands are available from the Command Library, see section: Creating RS232 Commands.
14. Double left click the desired RS232 command. The com­mand will appear in the Button Properties Window. (Refer to Figure 8) If there are commands already associated with the button being programmed, the RS232 com­mand will appear at the bottom of the list. The command
Figure 6 Select EZ-Pad
Figure 7 EZ-Pad Button and RSA-1.0 Selection
Page 6
RSA-1.0 Installation Instructions Page 6
can be moved up in the list by dragging and dropping the command to a different position. Be sure moving commands in the list does not adversely affect existing functionality.
15. The RS232 command line in the Button Properties Win­dow will show the blue ‘1010’ icon to indicate an RS232 command, the function, brand, component and ‘RSA-1.0 Add. 0 RS232’ indicating that the command has been properly associated with the RSA-1.0. If an EZ-Pad button press does not properly execute control functions, this is a good place to look in troubleshooting to confi rm Zone/ EZ-Pad/Button/RSA-1.0/RS232 command confi guration. See section: Troubleshooting for additional information.
16. Repeat steps 1-6 above to add RSA-1.0s.
17. Repeat steps 7-14 to program EZ-Pads with RS232 com­mands for RSA-1.0s.
ADDING NEW RS232 COMMANDS TO THE COMMAND LIBRARY
Figure 8 Programmed RSA-1.0 RS232 Command
New RS232 Commands can be quickly added to the EZ-Tools CMD Library. ASCII text strings of up to 100 characters can be added when either the ASCII or HEX code is known. Additionally, Baud Rate, Data Bits, Parity, Stop Bits, Character Delay, Response Length and Response Timeout can be set to assure proper performance of these control commands. ASCII, HEX and other code parameters can typically be found in product manuals or on manufacturers web sites. It may be necessary on occasion to contact a particular manufacturer’s tech support to get this information.
In some cases, the EZ-Tools CMD Library will already have IR codes or possibly some RS232 Commands for a particular Brand, Component and Model, and all that need be done is to add a couple of RS232 commands. In other cases, the Brand, Com­ponent and Model for which RS232 commands are required may not be in the CMD Library. Start with the appropriate step for the specifi c command(s) being added.
1. With EZ-Tools running, open the project for which the new RS232 Commands are required. (If not ready to program a specifi c project, open any EZ-Tools project.)
2. Left click the CMD Library Tab.
3. If the Brand name does not already exist, right click within the Brands space and left click “New Brand”. Type in the new brand name and click OK.
4. Right click the empty space below the brand name and left click “New Component”. Type in the new component name (i.e. Projector) and click OK.
5. Right click the new (Projector) folder and left click “New Model”. Type in the new model name (the model # of the com- ponent or it’s remote, i.e., VX-2c) and click OK.
6. Right click the new model # folder (i.e., VX-2c). Go to “New Commands” and left click “RS232 Serial Commands”. Type in command name (i.e., ON) and left click right arrows (>>) to put the name in the New Command List. Type in a complete list of command names (i.e., ON, OFF, COMPOSITE, S VIDEO 1, S VIDEO 2, etc.) as needed. (Refer to Figure
9)
7. When all new command names have been added to the New Command List, click OK.
8. The Command Properties Window will open automatically, with the fi rst new command already placed in the Command Name fi eld. (i.e. ON) (Refer to Figure 10)
Page 7
RSA-1.0 Installation Instructions Page 7
9. Left click Modify in the Com Port Settings box, to make any changes necessary to: Baud Rate, Data Bits, Parity and Stop bits, per the manufacturer’s protocol. The Serial Port Settings pop-up will appear. Make necessary changes and click OK. (Refer to Figure 10)
10. In the Command/Data Editor box, left click either the ASCII or HEX fi eld under “01” depending upon which data, ASCII or HEX will be used to create the new command. Type in the command string, one character per box, up to 100 characters.
11. In the Advanced Settings box select a Character Delay, from 0 (no delay) to 50 mS (milliseconds) if needed, to be inserted between characters when command strings are being sent.
12. In the Response Settings box, select the appropriate Response Length from 0 to 100 Characters to confi rm that the command string has been properly sent, received and executed.
Figure 9
Adding New RS232 Command Names
13. In the Response Settings box, select the appropriate Response Timeout from 0.0 to 10.0 seconds. This will determine the amount of time the RS232I/O Port will stay ‘open’ waiting for a response from the controlled device.
14. When all Command Properties for the specifi c command being edited have been made, click OK. The command will be added to the CMD Library and will be designated with a “1010” icon. The next New Command will automatically come up in the Command Properties Window. Typically, a manufacturer will use the same settings for baud, Data Bits, etc., so all that need be done is to type in the ASCII or HEX code for the individual commands. When all New Commands have been formatted, the Command Properties Window will close and all commands will be listed in the appropriate CMD Library List. (Refer to Figure 11)
Once RS232 Commands have been added to the CMD Library, they are available for use in any EZ-Tools project when programming RS232 codes is required.
Figure 10
Entering RS232 Command Properties
Figure 11
New RS232 Commands in Command Library
Page 8
RSA-1.0 Installation Instructions Page 8
SPECIFICATIONS
Dimensions: 4.3”L x 2.125”W x 1”H
Power Requirement: 12V DC; 200mA (SpeakerCraft PS-1.0 Power Supply)
Connectors Power: 2.1mm coaxial jack IR In: 3.5mm mini jack Network: 2 x RJ45 RS232: DB9M
Control Port: 3.5mm mini jack (4-circuit)
RS232 Parameters Baud Rate: 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600 Selectable Data Bits: 7, 8 Selectable Stop Bits: 1, 2 Selectable Parity: None, Odd, Even Selectable Command String: 100 Characters Max Character Delay: 0-50mS Response String: 0-100 Characters Response Timeout: 0.0-10.0 Seconds
Transmission Length Network (RS485): 1000’ Max RS232 Data I/O: 50’ Max
Page 9
RSA-1.0 Installation Instructions Page 9
LIMITED 2-YEAR WARRANTY
SpeakerCraft Inc. warrants to the original retail purchaser only that this SpeakerCraft product will be free from defects in materials and workmanship for a period of two years, provided the product was purchased from a SpeakerCraft Authorized Dealer.
Defective products must be shipped, together with proof of purchase, prepaid insured to the SpeakerCraft Authorized Dealer from whom they were purchased, or to the SpeakerCraft factory at the address listed on this installation instruction manual. Freight collect shipments will be refused. It is preferable to ship this product in the original shipping container to lessen the chance of transit damage. In any case, the risk or loss or damage in transit is to be borne by the purchaser. If, upon examination at the Factory or SpeakerCraft Authorized Dealer, it is determined that the unit was defective in materi­als or workmanship at any time during this warranty period, SpeakerCraft or the SpeakerCraft Authorized Dealer will, at its option, repair or replace this product at no additional charge, except as set forth below. If this model is no longer available and cannot be repaired effectively, SpeakerCraft, at its sole option, may replace the unit with a current model of equal or greater value. In some cases where a new model is substituted, a modification to the mounting surface may be required. If mounting surface modification is required, SpeakerCraft assumes no responsibility or liability for such modification. All replaced parts and product become the property of SpeakerCraft Inc. Products replaced or repaired under this Warranty will be returned to the original retail purchaser, within a reasonable time, freight prepaid.
This Warranty does not include service or parts to repair damage caused by accident, disaster, misuse, abuse, negligence, inadequate packing or shipping procedures, commercial use, voltage inputs in excess of the rated maximum of the unit, or service, repair or modification of the product which has not been authorized or approved by SpeakerCraft. This Warranty also excludes normal cosmetic deterioration caused by environmental conditions. This Warranty will be void if the Serial Number on the product has been removed, tampered with or defaced.
This Warranty is in lieu of all other expressed warranties. If the product is defective in materials or workmanship as warranted above, the purchaser’s sole remedy shall be repair or replacement as provided above. In no event will SpeakerCraft be liable for any incidental or consequential damages arising out of the use or inability to use the product, even if SpeakerCraft Inc. or a SpeakerCraft Inc. Authorized Dealer has been advised of the possibility of such damages, or for any claim by any other party. Some states do not allow the exclusion or limitation of consequential damages, so the above limitation and exclusion may not apply.
All implied warranties on the product are limited to the duration of this expressed Warranty. Some states do not allow limitation on the length of an implied warranty. If the original retail purchaser resides in such a state, this limitation does not apply.
SpeakerCraft offers a variety of accessories to make your installation of this and other SpeakerCraft products easy, econom­ical, and professional. Contact your authorized SpeakerCraft Dealer for more information.
For technical inquires, please call 1-800-448-0976 or e-mail us at techsupport@speakercraft.com. We are available to assist you every weekday, except holidays, between the hours of 7:00 a.m. and 5:00 p.m. PST.
Page 10
RSA-1.0 Installation Instructions Page 10
940 Columbia Avenue, Riverside, CA 92507 (800) 448-0976 Fax (951) 787-8747 www.speakercraft.com
LIT07105
Loading...