INSTALLATION INSTRUCTIONS - ARCEOS LED (ARS)
SAVE THESE INSTRUCTIONS
INSTALLATION
I
NSTRUCTIONS
ARCEOS SURFACE - ARS
READ THOROUGHLY BEFORE INSTALATION
WARNING! Fixtures must be grounded and installed in accordance with the National Electrical Code and all local codes.
Failure to do so may increase the RISK OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH. Install and
use so fixture failures do not cause a hazard and use only in environments for which the product is specifically marked.
WARNING! This product contains chemicals known to the State of California to cause cancer, birth defects, and/or other
reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
CAUTION! Follow ALL luminaire recommendations, product markings, instructions, restrictions and warnings regarding
luminaire operation and burning position. Luminaire label shows electrical and environmental requirements and
restrictions.
All electrical work must be done by a qualified electrician.
Turn off electric power to all affected circuits and allow to cool before servicing.
A regularly scheduled maintenance program should be established to retain optimum light output and reduce heat
retention. Dusting with a soft, clean, dry cloth is normally sufficient for the optical system. Any accumulation of dust or dirt
should be removed regularly.
Carefully read these instructions before installing product. If you do not understand these instructions, before starting any
work, contact your Hubbell Lighting distributor or techsupport@hubbell-ltg.com or (864) 678-1000
Give instructions to facility owner/manager for future reference.
NOTE:
This luminare is designed for outdoor lighting applications with ambient tempertures not exceeding 40°C
WARNINGS:
Dangerous voltage exist within the unit and all precautions usually observed in handling high voltage equipment should be observed
w
hen replacing light engine or otherwise servicing luminares. Disregarding this warning could result in electrical shock and possible
injury to the individual installing or servicing this equipment. Installation and servicing should be done by qualified personnel.
93054757 Rev.A
701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000
www.hubbelloutdoor.com

INSTALLATION INSTRUCTIONS - ARCEOS SURFACE LED (ARS)
Box using the hole pattern
ve the acorn nut and remove the
SAVE THESE INSTRUCTIONS
Installation Instructions
1. Remove Mounting Bracket from the fixture by removing screw and
sliding Mounting Bracket away from screw .
1
• Surface/J-Box Mounting
1. Remove Top Plate from Mounting Bracket by removing the 4
screws .
4
2. Install Mounting Bracket to the Surface or J-
provided.
• Note:
Pattern Indicator shows the distribution direction. Insure
Mounting Bracket is properly aligned for your application.
• Note: Mounting hardware not provided.
2
3
• Pendant Mounting
1. Install Mounting Bracket to pendant and secure by tightening
provided set screw .
• Note: When using fixture as a pendant mount use waterproof
pipe joint compound. (Not Provided)
• Note: Pattern Indicator shows the distribution direction. Insure
Mounting Bracket is properly aligned for your application.
2. Tilt the wire form up allowing it to sit up on its own. Now slide the
wire form in the hook on the Mounting Bracket.
6
3. Tighten screw to secure wire form in the hook.
6
8
4. Connect the supply wires in accordance with local and National Electrical
Codes. Push excess wires in the fixture.
5. Lift the fixture up and slide away from the hook on the Mounting
Bracket. Mounting Feet on the Mounting Bracket will go in the slot
on the top of the fixture. Once the mounting feet are engaged slide the
fixture towards the hook on the Mounting Bracket.
6. Secure the fixture by retightening mounting screw .
3
5
7
7
9
1
1
FIGURE 2
10
FIGURE 1
3
1
FIGURE 3
4
2
P
A
T
T
I
N
E
D
R
I
N
C
A
T
O
R
5
8
7
FIGURE 4
6
9
10
Maintenance
1. From underneath the fixture remove two mounting screws and
loosen the remaining screw . This will allow the lower section to open
11
for maintenance.
• Note: There is an acorn nut on one of the screws preventing it
13
from being removed.
2. If you want to remove lower section, remo
screw.
• Note: Disconnect wire connectors while fixture is hinged opened
before removing screw.
12
11
Wiring
This LED unit is supplied with electronic drivers having universal voltage and can
accept input voltage within the range of 120V – 277V or as a specified option
347V – 480V. When electric options are selected the fixture will be tied to a
specific voltage and cannot be changed.
NOTES:
No User Serviceable parts please contact Hubbell Lighting for any replacement parts.
Contact your local distributor or agent to confirm parts availability prior to ordering replacement parts.
701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000
FIGURE 5
13
12
12
www.hubbelloutdoor.com

INSTALLATION INSTRUCTIONS - ARCEOS SHIELD ACCESSORIES (ARS-SPC / ARS-CS)
SAVE THESE INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
ARS-SPC / ARS-CS
READ THOROUGHLY BEFORE INSTALLATION
1
INSTALLATION INSTRUCTIONS:
1. Remove all materials from carton.
2. Align holes on the shield with the castings .
3. Tighten three mounting screws .
NOTE
: Do not over tighten three mounting screws, Shield may crack.
1
3
2
3 3x
2
93054936 Rev.A
701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000
www.hubbelloutdoor.com

INSTALLATION INSTRUCTIONS - ARCEOS SURFACE BIRD SHIELD (ARS-BS)
SAVE THESE INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
ARS-BS
READ THOROUGHLY BEFORE INSTALLATION
INSTALLATION INSTRUCTIONS:
1. Remove all packaging materials from carton.
2. Loosen screws enough so the two ends seperate from each other.
3. Spread two ends apart and slide around Conduit Pipe.
1
4. Tighten screws with both ends together.
5. Remove Conduit Hub and replace it so the mounting flange on
SCP-BS is between Top casting and Conduit Hub.
NOTE
: Choose appropriate Conduit Hub that does not affect your
application
1
1
2
3
3
93055073 Rev.A
701 Millennium Boulevard Greenville, SC 29607 (864) 678-1000
2
www.hubbelloutdoor.com