ebios fire - Elipse & Quadra models incl. Mini series
GB 1
PREFACE / QUALITY PHILOSOPHY
You have decided in favour of a Spartherm ebios-fire - thank you for your
confidence in our company.
In a world of excess and mass production, our company stands for the values
expressed by our owner, Gerhard Manfred Rokossa:
„High technical quality combined with contemporary design and service to the
satisfaction of our customers so they will recommend us to others“.
Together with our specialist trade partners, we offer a range of first-class
products, which not only evoke passion, but also engender feelings of comfort and security. To achieve this, we recommend that you read the operating
instructions carefully in order to get a quick and comprehensive overview of
your decorative fireplace.
In addition to information on use, these instructions also include important
details on care and operation to guarantee your safety and the maintenance of
your ebios-fire as well as useful tips and guidance.
For further enquiries, please contact your specialist dealer.
We hope you enjoy your new stove.
Your Spartherm team
G.M. Rokossa
GB 2
CONTENTS
GB
1. General information 4
1.1 Scope of Delivery 5
2. Installation instructions 5
2.2 CER AM AT FN burner fleece 7
2.3 Basic requirements for installation 7
2.4 Installation site 7
2.5 Installation / assembly 8
2.5.1 Installation and assembly - Quadra and Elipse models 9
2.6 Fire protection 9
2.7 Combustion air supply 9
3. Operating Manual 10
3.1 General information on operation 10
3.2 Fire protection 11
3.3 Fuel 11
3.4 Startup 12
3.4.1 Startup of the models Elipse and Quadra 12
3.5 Refilling the burner 14
3.6 Taking out of operation safely 15
4. Cleaning and care 15
4.1 Cleaning cladding parts 15
5 Maintenance/troubleshooting 16
5.1 Furniture and glass (depending on the design) becomes
sooted heavily, rapidly and unevenly 16
5.2 Fire is difficult to ignite 16
5.3 Unpleasant odours 16
5.4 Appearance of flames changes 16
5.5 Spilt ethanol ignites 16
6. General warranty conditions 17
6.1 Scope of application 17
6.2 General information 17
6.3 Warranty period 17
6.4 Requirements for this warranty to be effective 17
6.5 Exclusion of warranty 17
6.6 Elimination of defects / repair 18
6.7 Extension of the warranty period 18
6.8 Spare par ts 18
6.9 Liability 18
6.10 Final comments 18
GB 3
IMPORTANT INFORMATION
1. GENERAL INFORMATION
As per the German Equipment and Product Safety Act (GPSG) and our
statutory duty to notify, we would like to inform you about heating with this
product.
The Bio Chimney combustion heat at 0.5 litres / hour equates to approx.
3,300 W. The calorific value of 96% ethanol equates to approx. 29,600 kJ
/ kg. With fuel consumption of 0.5 l/h (approx. 0.4 kg/h) the heat released
is approx. 3,300 W.
However, the decorative fireplace requires a plentiful supply of fresh air
when operated as otherwise the amount of carbon dioxide created exceeds
the permitted concentration in the room air.
As a rule, the fresh air supplied is cooler than the room air to be heated
up which results in a loss of energy. The effective heat output of a biofuel
fireplace is thus minimal and, as such, decorative fireplaces which use
biofuel are not sources of heat.
Rather these are merely decorative and are not intended for heating or
continuous operation. Nevertheless, it should be taken into account that
heat is generated as a by-product of the combustion process. This can
cause increased heating in the room where the fireplace is installed. Read
the safety instructions and measures for rear ventilation carefully.
Please pay attention to the contents of this Operating Manual.
Small children, elderly or infirm persons: as is the case with all open flames,
it is expedient that you attach a protective fixture for these groups of persons
Risk of burn injuries! Never leave these groups of persons unattended
near the ebios-fire when a fire is burning or has just been extinguished!
The ebios-fire must not be operated without supervision!
State-specific and local directives and regulations, in particular the fire
safety regulations of the German Federal State or the Association of Swiss
Canton Fire Insurance companies (VKF) must be complied with for the setup and operation of your ebios-fire.
Most ebios-fire units are inspected for compliance with DIN 4734-1 or DIN
EN 16647 standards. All devices incorporate state-of-the-art technology.
Ensure sufficient stability when setting up the fireplace and choose a location where movement of the burner during operation as a result of impacts
etc. is ruled out.
All models may only be operated with the closed housing cover.
Please note that the fuel may not be refilled whilst the device is still warm
or burning. The device may ONLY be refilled via the filling opening and NOT
via the burner channel! (see Fig. 1) We recommend that you put out the
ebios-fire by running it until the fuel tank runs dry.
When not in use, the cover plates must always be placed over the
burner.
GB 4
Only allow the device to be refilled by individuals who are familiar with the
safety instructions and who you have trained on its operation.
The ebios-fire is not a heater but a decorative fire.
Bioethanol is a dangerous substance and must only be stored in the prescribed quantities as per the regulations:
Storage in a cellar: max. 20 litres
Storage in living space: max. 5 litres
1.1 SCOPE OF DELIVERY
GB
ebios-fire with the following features:
• Standing or suspended fireplace
• 1 burner made of stainless steel
• 1 burner mat made of Ceramat FN
• Safety container for all burner types made of stainless steel
• Cover plate (with recess for grip stick) made of stainless steel
• Bottle for moistening the burner mat
• Tank lock with seal
• Fill level indicator
• Wrench for opening and closing the tank lock
• Cold hand for lifting off and setting down the cover plate.
• Funnel for filling the burner
• Stick lighter
• Rating plate
• Ethanol 5L canister with outlet valve for initial commissioning
(only within Germany)
• Supplied pre-assembled in transport-friendly disposable cardboard
packaging
Fig.1
ItemDesignation
ACover plate
BFill level indicator
CFilling opening
DBurner channel
ESafety container
FTank
2. INSTALLATION INSTRUCTIONS
The device must not be able to tilt and must be positioned horizontally.
Secure the wall-mounted models and floor-mounted models on the wall or
floor. This is in the interest of your own safety.
GB 5
2.1 TECHNICAL DATA
An overview of the models:
ebios-fire
Fuel type:
Filling quantity (depending on model):1.2 - 2.6 l
Fuel consumption:0.4- 0.5 l/hr
Burning duration (depending on the model):approx. 3 - 5 hrs*
Temperature in the tank:< 65°C
Weight of burners (empty) with cover plate:4.0-5.3 kg
Minimum room volume per burner: **84 m³167 m³418 m³
Air exchange at air exchange rate: **10.50.2
Corresponding room size with room height of 2.5 m **34 m²67 m²167 m²
Bioethanol
(ethanol content 96%)
As a rough rule of thumb the following air exchange figures 1)can be stated:
** Please note that the luminosity of the flame can decrease to such an
extent that the flame is no longer clearly visible. Make children and others
in the home aware of this.
** These details relate solely to the combustion air requirements of the
ebios-fire. Should you have additional air-consuming devices installed in
the room, these must be taken into consideration separately.
ModelElipse BaseElipse WallElipse Wall Mini
PositioningFloorWallWall
Number of
burners
Width in mm960960700
Depth in mm235290225
Height in mm220405385
Weight in kg19,52413
111
ModelElipse Base MiniQuadra BaseQuadra Wall
PositioningFloorFloorWall
Number of
burners
Width in mm700600600
Depth in mm180290330
Height in mm168220400
Weight in kg10,51925
111
ModelElipse Z
PositioningFloor
Number of
burners
Width in mm960
Depth in mm240
Height in mm530
Weight in kg44,5
1
GB 6
GB
2.2 CERAMAT FN BURNER FLEECE
The CERAMAT FN burner fleece (black) included should only be touched
when wearing gloves as there is otherwise a risk of skin irritations. The
material can be easily damaged. As such, the mat should not be folded,
bent or similar.
2.3 BASIC REQUIREMENTS FOR INSTALLATION
All the relevant national and European standards as well as the local regulations (fire protection regulations etc.) must be observed and applied during
installation and operation of the ebios-fire! The list of regulations given
below is not exhaustive.
BetrSichVOperational safety ordinance
VbfFlammable liquids directive
BsVFire protection directive of the relevant German federal state (Bundesland)
LBOFederal state construction directives
GefStoffVHazardous substances directive
The ebios-fire may only be set up in rooms and locations where there are
no hazards due to the site, structural conditions and type of use. The floor
area of the installation room must be designed and dimensioned so that the
ebios-fire can be operated properly and as per the intended use.
Only permitted and sufficiently strong transport aids may be used to transport the ebios-fire. The following points must be noted to ensure safe and
problem-free transport.
• Transport aids (if necessary), special hand trucks must only be loaded
with the rear of the ebios-fire facing down.
• There must be no fuel in the tank during transportation.
DAMAGE DURING TRANSIT should be reported immediately to the supplier.
Protect the cladding and visible elements of the fireplace furniture from
soiling and damage during installation and transportation.
2.4 INSTALLATION SITE
When setting up/installing the ebios-fire ensure that the device is not positioned within the direct radiation area of large heat sources (heaters, stoves
etc.) or in rooms exposed to high temperatures (e.g., saunas).
External heating of the ethanol fire area while not in operation can cause the
fuel in the tank to be driven out through the burner channel and to collect
in the safety tank.
In such cases, the burner is to be removed and the tray emptied before the
ebios-fire is lit.
Your ebios-fire must not be installed in:
• In stairways, unless they are in residential buildings with two or fewer
flats.
• In hallways with general access.
• In garages.
• In rooms in which highly combustible or potentially explosive substances
or mixtures are processed, stored or manufactured in quantities that
would be hazardous in the event of ignition or explo-sion
• In insufficiently ventilated rooms.
• In areas accessible to the public which are not supervised.
GB 7
• In areas which are not protected against transverse ventilation
• On tables, pieces of furniture, shelves etc.
• In entrance areas of hotel lobbies, bars, restaurants etc. where higher
air change rates can be expected. (draught)
2.5 INSTALLATION / ASSEMBLY
The ebios-fire model, whether as a floor- or wall-mounted version, must be
aligned horizontally and protected from tilting. Secure wall-mounted models
to the wall and floor-mounted models to either the wall or the floor. Please
note the safety distances (Fig. 4 radiation area). Rear ventilation must not
be closed. Place the burner with safety container and cover plate in the
designated holders in the furniture.
Floor-mounted furniture may only be set up on floors with sufficient loadbearing capacity. If the load bearing capacity is not sufficient, suitable
measures must be taken (e.g., plate for load distribution) to remedy this.
Use suitable fastening material (wall plugs, screws etc.) when securing to
the wall.
After installing the wall-mounted appliance on the wall, the appliance is to
be secured from being accidentally pushed upwards/dismounted using the
spin-lock.
Thread
GB 8
GB
2.5.1 INSTALLATION AND ASSEMBLY -
QUADRA AND ELIPSE MODELS
Close the furniture housing cover of the device. Please ensure correct positioning so that there is a uniform (depending on the model see Fig. 2 or
Fig. 3) air gap between the housing cover and flame area so as to ensure a
sufficient supply of air. Otherwise the housing cover can become covered in
soot and the flames may no longer be uniform in appearance.
Housing cover.
Burner
Fig. 2
(View may vary from your model)
Air gap approx. 9 mm (without cover plate)
Housing cover.
Burner
2.6 FIRE PROTECTION
In order to guarantee sufficient thermal insulation, there must be a minimum distance of 300 mm (see Fig. 4) to flammable components, furniture,
decorations and curtains at the side! There must be no objects between
the ebios-fire furniture and room ceiling (distance to ceiling > 1000 mm).
Fig. 4
2.7 COMBUSTION AIR SUPPLY
Your ebios-fire draws its combustion air from the room in which it is
installed (dependent on indoor air). It must be ensured that there is a sufficient supply of fresh air to the room in which the fire is installed. It is
possible that there is not a sufficient supply of fresh air if the windows and
doors are sealed (e.g., in combination with energy saving measures). This
can compromise your well-being and, under certain circumstances, also
your safety and the combustion performance. Open a window to ensure a
sufficient supply of fresh air.
(View may vary from your model)
Air gap approx. 7 mm (without cover plate)
Fig. 3
GB 9
3. OPERATING MANUAL
Read these installation and operating instructions carefully before installing
and starting up your ebios-fire. All objects must be removed from the ebiosfire furniture (except for the burner unit).
Please follow the regulations for fire protection and dangerous goods!
3.1 GENERAL INFORMATION ON OPERATION
• Small children, elderly or infirm persons: As is the case with all open
flames, it is expedient that you attach a protective fixture for these
groups of persons (available as an accessory from specialist dealers)
Risk of burn injuries! Never leave these groups of persons unattended
near the ebios-fire when a fire is burning or has just been extinguished!
Make these individuals aware of these risks.
• No combustible objects may be placed or laid on the free surfaces of the
ebios-fire. Do not place items of clothing on the ebios-fire furniture to
dry. Racks for drying clothing may only be placed outside the radiation
area (Fig. 4)! Risk of fires!
• Thermal energy is released during the combustion process which causes
the burner, the housing surfaces, the glass panes (depending on the
model) and the protective glass panes to heat up. It is not permitted to
touch these items without taking the necessary precautions (e.g., heatresistant glove). Risk of burn injuries!
• Never leave the fire unattended whilst it is alight!
• With all models (Elipse and Quadra), ensure that the housing covers are
closed and that the protective panes are inserted.
• It is recommended to open a window during operation.
• Several decorative ethanol fireplaces may only be operated if the fuel
consumption rate of all devices together does not exceed 0.5 l/h and if
additional measures are taken to ensure sufficient ventilation. In this
context, please observe the table on page 6, under item 2.1. Technical
data.
• The burner may only be operated with the burner mat and these wicks.
It is not permitted to change the number of wicks, the wick material or
the burner mat.
• The ebios-fire appliances must not be modified.
• This is merely a decorative fireplace for use in the home and is not
intended for heating or continuous operation! Nevertheless, it should
be taken into account that heat (approx. 3 kW) is generated as a byproduct of the combustion process. Amongst other things this can cause
increased heating in the room where the fireplace is installed.
• There should never be any fuel in the tank and the cover must always be
placed on the burner when the latter is not in use.
• The burners are designed for the fuel to be burnt until all gone. If you
only wish to enjoy the flames for a short period of time, use a correspondingly smaller amount of fuel. If you wish to take the burner out of
operation prematurely, place the cover on the burner with the aid of the
grip stick. After shutting down the burner, always allow at least 1 hour
• The burner must NOT be filled when warm or alight and must NOT be
filled via the burner channel! DANGER TO LIFE!
GB 10
GB
• The handling of fuel in the vicinity of the hot or burning device is associated with significant risks and is not permitted!
• Only fill the burner via the filling opening and never via the burner channel! (see Fig. 1)
• Should you accidentally spill ethanol, clean this up immediately and
before lighting the burner!
• Please note that the luminosity of the flame can decrease to such an
extent that the flame is no longer clearly visible. Make children and
others in the home aware of this.
• Minimum waiting time between extinguishing and refilling the burner
= 1 hour!
• Do not smoke when handling fuel and operating the ebios-fire.
Failure to follow these basic rules can result in uncontrolled ignition
or even explosions!
3.2 FIRE PROTECTION
Please note: In the radiation area Fig. 4 (in the area of the flames/furniture)
the flammable components and furniture within 1000 mm upwards and 300
mm to the sides must be fitted with ventilated radiation protection on both
sides.
There must be no flammable objects (decorations, clothing etc.) in the radiation area. In
order to guarantee sufficient thermal insulation, there must be a minimum distance of
300 mm to flammable components at the side,
furniture, decorations and curtains! There must be no objects between the
fireplace and room ceiling (distance to the ceiling >1000 mm)!
300 mm
3.3 FUEL
Bioethanol (chemical formula C2H6O) with an ethanol content of 96.6% is
used as the fuel. It is available from your specialist dealer. It is a dangerous
substance as per ADR: Class 3 PG II, UN 1170.
Under no circumstances should other fuels such as petrol, spirit or similar
flammable liquids be used. Do not mix the fuels together or with other
substances. The burners may only be operated using the prescribed fuel
otherwise the warranty will be rendered void and the device may be unsafe
to operate.
Ethanol is a highly flammable liquid which must be stored well sealed, protected from light and away from sources of fire. It is permitted to store max.
5 l in the living space and max. 20 l in the cellar. Keep bioethanol out of
the reach of children. For your safety only fill the burner just before use to
prevent it from being ignited unintentionally or by unauthorised persons and
to also stop the fuel from evaporating.
Please note that ethanol is used exclusively for combustion and it not suitable for consumption. Supervise your children! If swallowed consult a doctor
immediately and present the fuel label.
GB 11
3.4 STARTUP
The ebios-fire devices are supplied with empty burners to prevent any
ethanol from flowing out or evaporating during transit. Ensure (particularly
before being put into use) that there is no fuel in the safety container.
3.4.1 STARTUP OF THE MODELS ELIPSE AND
QUADRA
Proceed as follows:
1. Ensure that the air supply is sufficient. (see 2.7)
2. Make sure that the burner has gone out and has cooled down fully
(minimum waiting time after being extinguished = 1 hour).
3. The burner remains in the housing when being refilled. For this re-move
the protective panes and then open the housing cover.
4. Check the tank content.
5. Make sure that the cover plate is placed on the burner and covers the
burner mat.
6. Use a wrench to open the filling screw.
7. Insert the funnel into the filling opening and pour in a maximum of 2.6
l of bioethanol.
GB 12
GB
8. The fill level indicator shows the maximum permitted fill level. The maximum fill level is achieved once the red fill level ball floats to the top.
9. Take the bottle to wet the burner. (Fig. Similar) Guide bottle with the
opening into the tank opening until it protrudes right into the fuel. Press
the bottle together so that the air escapes and the fuel is sucked up
when it is released. Wait until the bottle returns to its original shape.
10. Seal the filling plug securely using the wrench.
11. Close the housing cover on the device and ensure that the cover does
not extend into the flame area and instead maintains a uniform distance
from the burner channel (depending on model, refer to Fig. 2 or Fig. 3).
Then insert the protective panes.
12. Insert the cold hand to grip the cover plate and lift it off.
13. Wet the burner fleece with fuel using the bottle which has just been
filled.
GB 13
14. Put the bottle down to one side.
15. Wait for approx. 30 seconds with ignition to enable the wick to be-come
fully impregnated with ethanol.
16. Ignite the fire on the side of the burner mat and step back from the
flames. It may take a few minutes until uniform flames appear.
Should you ever pour in too much fuel and cause the burner to overflow,
the ethanol collects in the safety container. Empty this immediately and
before lighting the burner. Clean the surface of the burner until it is
dry and completely free of ethanol.
3.5 REFILLING THE BURNER
The burner must NOT be filled when warm or alight and must NOT be filled
via the burner channel! DANGER TO LIFE!
Proceed as follows to refill:
1. Ensure that the air supply is sufficient. (see 2.7)
2. Make sure that the burner has gone out and has cooled down fully
(minimum waiting time after being extinguished = 1 hour).
3. The burner remains in the housing when being refilled. For this remove
the protective panes and then open the housing cover.
4. Check the tank content.
5. Make sure that the cover plate is placed on the burner and covers the
burner mat.
6. Use a wrench to open the filling screw.
Minimum waiting time between extinguishing and refilling the burner = 1
hour!
Please also leave the protective panes which may still be hot on the device
during this time! Risk of burn injuries!
The burners are designed for the fuel to be burnt until all gone. If you only
wish to enjoy the flames for a short period of time, use a correspondingly
smaller amount of fuel. If you wish to take the burner out of operation
prematurely, place the cover on the burner with the aid of the grip stick.
7. Insert the funnel into the filling opening and pour in a maximum of 2.6 l
of bioethanol. (max. 1.2 litres on the Mini models)
GB 14
GB
8. The fill level indicator shows the maximum permitted fill level.The maximum fill level is reached when the bioethanol runs out of the slit (see
arrow) into the reflector curve.
Should you ever pour in too much fuel and cause the burner to overflow,
the ethanol collects in the safety container. Empty this immediately and
before lighting the burner. Clean the surface of the burner until it is dry and
completely free of ethanol.
To ignite the burner, follow the steps 9-16 described in Point 3.4.1!
3.6 TAKING OUT OF OPERATION SAFELY
If you wish to take the burner out of operation prematurely, place the cover
on the burner with the aid of the grip stick.
Insert the grip stick to grip the cover plate and then cover this over the
burner channel.
4. CLEANING AND CARE
The ebios-fire furniture may only be cleaned when cold.
4.1 CLEANING CLADDING PARTS
• Wait until the device has cooled down before cleaning (at least 1 hour)!
• Decorative metal surfaces and the cladding parts can be cleaned with
a moist cloth (do not use a microfibre cloth!).
• Glass surfaces can be cleaned with a standard glass cleaner and a soft
cloth (do not use a microfibre cloth!).
• Stainless steel surfaces can be cleaned with a standard stainless
• steel cleaning agent. Only use in the direction of the finish!
Remove any dust on and below the ebios-fire furniture regularly as dust
particles can burn or char. This can cause dirt in the room and on the
furnishings where the fire is installed.
GB 15
5 MAINTENANCE/TROUBLESHOOTING
5.3 UNPLEASANT ODOURS
• The wick and burner fleece must be visually inspected at regular intervals. The material can be easily damaged. As such, the burner fleece
should not be folded, bent or similar. It is not permitted to change the
burner mat or wick.
• The burner mat must be replaced after approx. 380 service hours (corresponds to a fuel throughput of around 190 l bioethanol). Please contact
your specialist dealer.
• Only use our original spare parts.
• The tank seal must be examined occasionally for cracks or brittleness
and should be replaced if necessary.
• Please contact your specialist dealer should you have any questions.
5.1 FURNITURE AND GLASS (DEPENDING ON THE
DESIGN) BECOMES SOOTED HEAVILY, RAPIDLY
AND UNEVENLY
If this did not occur from the very start, please check the following points:
• Has the correct fuel been used? (see 3.3).
• Cladding/cover correctly positioned? (see 2.5)
5.2 FIRE IS DIFFICULT TO IGNITE
If this did not occur from the very start, please check the following points:
• Is there fuel in the burner? (see 3.5)
• Have you wetted the ignition mats? (see 3.4)
• Has the correct fuel been used? (see 3.3).
• Fuel in a burner which is not in use? (see 3.1)
• Cover plate in position? (see 3.1)
• Fuel was spilt when filling the device? (see 3.5)
5.4 APPEARANCE OF FLAMES CHANGES
• Is the burner fleece damaged? (see 5)
• Has the correct fuel been used? (see 3.3).
• Were all safety distances observed? (3.2)
• Is the site of installation sufficiently ventilated? (2.7)
• Is the installation site protected from transverse ventilation? (2.4)
If the appearance of the flames changes noticeably, especially if the flames
begin to extend above the protective pane, stop using the device (see 3.6)
and notify the specialist dealer.
5.5 SPILT ETHANOL IGNITES
If spilt ethanol is ignited, attempt to put out the flames immediately. Use,
for example, foam fire extinguishers with alcohol-resistant foam or suitable
fire blankets. We recommend that such extinguishing agents be kept at the
ready. Should it not be possible to extinguish the fire rapidly, the fire service
must be notified immediately and their instructions followed.
GB 16
GB
6. GENERAL WARRANTY CONDITIONS
6.1 SCOPE OF APPLICATION
These standard warranty terms apply for the contractual relationship
between the manufacturer, Spartherm Feuerungstechnik GmbH, and the
dealer/distributor. They are not congruent with the contractual and warranty
terms which the dealer/distributor offers his customers in individual cases.
6.2 GENERAL INFORMATION
This product has been manufactured in compliance with current standards
of quality control. The materials used have been carefully selected and - like
the production process - are subject to on-going quality control.
Specialist knowledge is required when assembling and installing the
product. The product must, therefore, only be installed and started up by
specialist technical staff, in compliance with current statutory provisions.
6.3 WARRANTY PERIOD
The standard warranty terms only apply within Germany and the European
Union. The warranty period and scope of the warranty are ensured within the
framework of these conditions outside the statutory warranty which remains
unaffected.
Spartherm Feuerungstechnik GmbH grants a 24-month warranty on ebiosfire devices.
Spartherm Feuerungstechnik GmbH grants a 6-month warranty on wearing
parts in the fire area, e.g., wicks, burner mats, seals and glass ceramic.
6.4 REQUIREMENTS FOR THIS WARRANTY TO BE
EFFECTIVE
The warranty period shall begin on the date, on which the product is delivered to the dealer / distributor. Invoices or delivery notes may be used as
confirmation of the warranty commencement date. The warranty certificate
for the product must be presented by the claimant upon making a warranty
claim. Spartherm Feuerungstechnik GmbH is not obliged to satisfy any claim
if such documentation is not presented.
6.5 EXCLUSION OF WARRANTY
This warranty does not cover:
• component wear
• Wick/burner mat due to thermal stress
• the fireplace surfaces: Discolouration of the finish or on the galvanic
surfaces of the furniture and/or burner which are a result of thermal
stresses or overloading
• the glass panes: contamination, due to soot or other burnt-on combus-
tion materials and visual deterioration due to thermal loading.
• Use of unsuitable or non-designated fuel.
• We recommend bioethanol from Spartherm Feuerungstechnik GmbH
with a concentration in excess of 96% for your ebios-fire device.
• inappropriate or careless handling of fragile components, such as glass
or ceramics
• improper operation and/or use
• incorrect filling of system
• lack of maintenance
• incorrect set-up/installation of device
• failure to comply with Installation and Operating Manual
• technical modifications made to the appliance by third parties
GB 17
6.6 ELIMINATION OF DEFECTS / REPAIR
6.9 LIABILITY
Independent of any statutory provisions acknowledged as taking precedence
over the terms of this warranty, all necessary repair works resulting from
material or manufacturing defect shall be carried out free-of-charge in the
context of this warranty and shall not invalidate the remaining provisions of
the warranty.
Within the scope of this warranty promise Spartherm Feuerungstechnik
GmbH reserves the right to either remedy the fault or replace the device free
of charge. The elimination of defects shall take precedence. The terms of
this warranty shall not extend to any damage or compensation not covered
by statutory provisions.
6.7 EXTENSION OF THE WARRANTY PERIOD
The warranty period shall automatically be extended, where claims made in
respect of these warranty provisions result in the repair or replacement of
defective equipment.
6.8 SPA RE PARTS
Only the manufacturer’s own components, or replacement parts recommend-ed and approved by the manufacturer, shall be used for appliance
servicing and repair.
Damages and claims for compensation which are not the result of delivery of a defective appliance from Spartherm Feuerungstechnik GmbH are
excluded and are not part of this warranty promise. The above shall not
include claims made in respect of statutory legal requirements.
6.10 FINAL COMMENTS
In addition to these warranty conditions and our commitment to them, our
dealers and contractual partners are pledged to assist you in both word
and deed. It is expressly recommended to have ebios-fire products checked
regularly by a stove fitter/specialist dealer.
We reserve the right to make alterations to the technical data contained
herein and accept no liability in respect of any errors made.
GB 18
We reserve the right to make alterations to the technical data contained herein and accept no liability in
respect of any errors made.
NOTES
GB
GB 19
SPARTHERM
DIE WELTMARKE FÜR IHR WOHNZIMMER
The Global brand for your living room | La référence mondiale pour votre salon | Il marchio mondiale per il vostro soggiorno
La marca mundial para su salón | Het merk van wereldformaat voor uw woonkamer | Światowa marka do Państwa salonu
Торговая марка № 1 для Вашего дома
D Ihr Fachhändler | UK Your specialist dealer | F Votre revendeur spécialisé
IT Il vostro rivenditore specializzato | E Sus comercios especializados