PREFACE / QUALITY PHILOSOPHY
You have decided in favour of a Spartherm ebios-fire - thank you for your confidence in our company.
In a world of excess and mass production, our company stands for the values expressed by our owner, Gerhard Manfred Rokossa:
„High technical quality combined with contemporary design and service to the satisfaction of our customers so they will recommend us to others“.
Together with our specialist trade partners, we offer a range of first-class products, which not only evoke passion, but also engender feelings of com­fort and security. To achieve this, we recommend that you read the operating instructions carefully in order to get a quick and comprehensive overview of your decorative fireplace.
In addition to information on use, these instructions also include important details on care and operation to guarantee your safety and the maintenance of your ebios-fire as well as useful tips and guidance.
For further enquiries, please contact your specialist dealer. We hope you enjoy your new stove.
Your Spartherm team G.M. Rokossa
GB 2
CONTENTS
GB
1. General information 4
1.1 Scope of Delivery 5
2. Installation instructions 5
2.2 CER AM AT FN burner fleece 7
2.3 Basic requirements for installation 7
2.4 Installation site 7
2.5 Installation / assembly 8
2.5.1 Installation and assembly - Quadra and Elipse models 9
2.6 Fire protection 9
2.7 Combustion air supply 9
3. Operating Manual 10
3.1 General information on operation 10
3.2 Fire protection 11
3.3 Fuel 11
3.4 Startup 12
3.4.1 Startup of the models Elipse and Quadra 12
3.5 Refilling the burner 14
3.6 Taking out of operation safely 15
4. Cleaning and care 15
4.1 Cleaning cladding parts 15
5 Maintenance/troubleshooting 16
5.1 Furniture and glass (depending on the design) becomes sooted heavily, rapidly and unevenly 16
5.2 Fire is difficult to ignite 16
5.3 Unpleasant odours 16
5.4 Appearance of flames changes 16
5.5 Spilt ethanol ignites 16
6. General warranty conditions 17
6.1 Scope of application 17
6.2 General information 17
6.3 Warranty period 17
6.4 Requirements for this warranty to be effective 17
6.5 Exclusion of warranty 17
6.6 Elimination of defects / repair 18
6.7 Extension of the warranty period 18
6.8 Spare par ts 18
6.9 Liability 18
6.10 Final comments 18
GB 3
IMPORTANT INFORMATION
1. GENERAL INFORMATION
As per the German Equipment and Product Safety Act (GPSG) and our statutory duty to notify, we would like to inform you about heating with this product.
The Bio Chimney combustion heat at 0.5 litres / hour equates to approx. 3,300 W. The calorific value of 96% ethanol equates to approx. 29,600 kJ / kg. With fuel consumption of 0.5 l/h (approx. 0.4 kg/h) the heat released is approx. 3,300 W.
However, the decorative fireplace requires a plentiful supply of fresh air when operated as otherwise the amount of carbon dioxide created exceeds the permitted concentration in the room air.
As a rule, the fresh air supplied is cooler than the room air to be heated up which results in a loss of energy. The effective heat output of a biofuel fireplace is thus minimal and, as such, decorative fireplaces which use biofuel are not sources of heat.
Rather these are merely decorative and are not intended for heating or continuous operation. Nevertheless, it should be taken into account that heat is generated as a by-product of the combustion process. This can cause increased heating in the room where the fireplace is installed. Read the safety instructions and measures for rear ventilation carefully.
Please pay attention to the contents of this Operating Manual.
Small children, elderly or infirm persons: as is the case with all open flames, it is expedient that you attach a protective fixture for these groups of persons Risk of burn injuries! Never leave these groups of persons unattended near the ebios-fire when a fire is burning or has just been extinguished!
The ebios-fire must not be operated without supervision!
State-specific and local directives and regulations, in particular the fire safety regulations of the German Federal State or the Association of Swiss Canton Fire Insurance companies (VKF) must be complied with for the set­up and operation of your ebios-fire.
Most ebios-fire units are inspected for compliance with DIN 4734-1 or DIN EN 16647 standards. All devices incorporate state-of-the-art technology.
Ensure sufficient stability when setting up the fireplace and choose a loca­tion where movement of the burner during operation as a result of impacts etc. is ruled out.
All models may only be operated with the closed housing cover.
Please note that the fuel may not be refilled whilst the device is still warm or burning. The device may ONLY be refilled via the filling opening and NOT via the burner channel! (see Fig. 1) We recommend that you put out the ebios-fire by running it until the fuel tank runs dry.
When not in use, the cover plates must always be placed over the burner.
GB 4
Only allow the device to be refilled by individuals who are familiar with the safety instructions and who you have trained on its operation.
The ebios-fire is not a heater but a decorative fire.
Bioethanol is a dangerous substance and must only be stored in the pre­scribed quantities as per the regulations:
Storage in a cellar: max. 20 litres Storage in living space: max. 5 litres
1.1 SCOPE OF DELIVERY
GB
ebios-fire with the following features:
• Standing or suspended fireplace
• 1 burner made of stainless steel
• 1 burner mat made of Ceramat FN
• Safety container for all burner types made of stainless steel
• Cover plate (with recess for grip stick) made of stainless steel
• Bottle for moistening the burner mat
• Tank lock with seal
• Fill level indicator
• Wrench for opening and closing the tank lock
• Cold hand for lifting off and setting down the cover plate.
• Funnel for filling the burner
• Stick lighter
• Rating plate
• Ethanol 5L canister with outlet valve for initial commissioning
(only within Germany)
• Supplied pre-assembled in transport-friendly disposable cardboard packaging
Fig.1
Item Designation
A Cover plate
B Fill level indicator
C Filling opening
D Burner channel
E Safety container
F Tank
2. INSTALLATION INSTRUCTIONS
The device must not be able to tilt and must be positioned horizontally. Secure the wall-mounted models and floor-mounted models on the wall or floor. This is in the interest of your own safety.
GB 5
2.1 TECHNICAL DATA
An overview of the models:
ebios-fire
Fuel type:
Filling quantity (depending on model): 1.2 - 2.6 l
Fuel consumption: 0.4- 0.5 l/hr
Burning duration (depending on the model): approx. 3 - 5 hrs*
Temperature in the tank: < 65°C
Weight of burners (empty) with cover plate: 4.0-5.3 kg
Minimum room volume per burner: ** 84 m³ 167 m³ 418 m³
Air exchange at air exchange rate: ** 1 0.5 0.2
Corresponding room size with room height of 2.5 m ** 34 m² 67 m² 167 m²
Bioethanol
(ethanol content 96%)
As a rough rule of thumb the following air exchange figures 1)can be stated:
Air exchange [1/hr] Comments
0…0.5 Windows and doors closed
0.3…1.5 Window tilted, no roller blinds
5…10 Window half open
1)
Recknagel, Sprenger, Schrameck: Heizung+Klimatechnik, Oldenbourg Verlag
** Please note that the luminosity of the flame can decrease to such an
extent that the flame is no longer clearly visible. Make children and others in the home aware of this.
** These details relate solely to the combustion air requirements of the
ebios-fire. Should you have additional air-consuming devices installed in the room, these must be taken into consideration separately.
Model Elipse Base Elipse Wall Elipse Wall Mini
Positioning Floor Wall Wall
Number of burners
Width in mm 960 960 700
Depth in mm 235 290 225
Height in mm 220 405 385
Weight in kg 19,5 24 13
1 1 1
Model Elipse Base Mini Quadra Base Quadra Wall
Positioning Floor Floor Wall
Number of burners
Width in mm 700 600 600
Depth in mm 180 290 330
Height in mm 168 220 400
Weight in kg 10,5 19 25
1 1 1
Model Elipse Z
Positioning Floor
Number of burners
Width in mm 960
Depth in mm 240
Height in mm 530
Weight in kg 44,5
1
GB 6
GB
2.2 CERAMAT FN BURNER FLEECE
The CERAMAT FN burner fleece (black) included should only be touched when wearing gloves as there is otherwise a risk of skin irritations. The material can be easily damaged. As such, the mat should not be folded, bent or similar.
2.3 BASIC REQUIREMENTS FOR INSTALLATION
All the relevant national and European standards as well as the local regula­tions (fire protection regulations etc.) must be observed and applied during installation and operation of the ebios-fire! The list of regulations given below is not exhaustive.
BetrSichV Operational safety ordinance
Vbf Flammable liquids directive
BsV Fire protection directive of the relevant German federal state (Bundesland)
LBO Federal state construction directives
GefStoffV Hazardous substances directive
The ebios-fire may only be set up in rooms and locations where there are no hazards due to the site, structural conditions and type of use. The floor area of the installation room must be designed and dimensioned so that the ebios-fire can be operated properly and as per the intended use.
Only permitted and sufficiently strong transport aids may be used to trans­port the ebios-fire. The following points must be noted to ensure safe and problem-free transport.
• Transport aids (if necessary), special hand trucks must only be loaded with the rear of the ebios-fire facing down.
• There must be no fuel in the tank during transportation.
DAMAGE DURING TRANSIT should be reported immediately to the supplier. Protect the cladding and visible elements of the fireplace furniture from soiling and damage during installation and transportation.
2.4 INSTALLATION SITE
When setting up/installing the ebios-fire ensure that the device is not posi­tioned within the direct radiation area of large heat sources (heaters, stoves etc.) or in rooms exposed to high temperatures (e.g., saunas).
External heating of the ethanol fire area while not in operation can cause the fuel in the tank to be driven out through the burner channel and to collect in the safety tank.
In such cases, the burner is to be removed and the tray emptied before the ebios-fire is lit.
Your ebios-fire must not be installed in:
• In stairways, unless they are in residential buildings with two or fewer flats.
• In hallways with general access.
• In garages.
• In rooms in which highly combustible or potentially explosive substances or mixtures are processed, stored or manufactured in quantities that would be hazardous in the event of ignition or explo-sion
• In insufficiently ventilated rooms.
• In areas accessible to the public which are not supervised.
GB 7
• In areas which are not protected against transverse ventilation
• On tables, pieces of furniture, shelves etc.
• In entrance areas of hotel lobbies, bars, restaurants etc. where higher air change rates can be expected. (draught)
2.5 INSTALLATION / ASSEMBLY
The ebios-fire model, whether as a floor- or wall-mounted version, must be aligned horizontally and protected from tilting. Secure wall-mounted models to the wall and floor-mounted models to either the wall or the floor. Please note the safety distances (Fig. 4 radiation area). Rear ventilation must not be closed. Place the burner with safety container and cover plate in the designated holders in the furniture.
Floor-mounted furniture may only be set up on floors with sufficient load­bearing capacity. If the load bearing capacity is not sufficient, suitable measures must be taken (e.g., plate for load distribution) to remedy this.
Use suitable fastening material (wall plugs, screws etc.) when securing to the wall.
After installing the wall-mounted appliance on the wall, the appliance is to be secured from being accidentally pushed upwards/dismounted using the spin-lock.
Thread
GB 8
GB
2.5.1 INSTALLATION AND ASSEMBLY - QUADRA AND ELIPSE MODELS
Close the furniture housing cover of the device. Please ensure correct posi­tioning so that there is a uniform (depending on the model see Fig. 2 or Fig. 3) air gap between the housing cover and flame area so as to ensure a sufficient supply of air. Otherwise the housing cover can become covered in soot and the flames may no longer be uniform in appearance.
Housing cover.
Burner
Fig. 2
(View may vary from your model)
Air gap approx. 9 mm (without cover plate)
Housing cover.
Burner
2.6 FIRE PROTECTION
In order to guarantee sufficient thermal insulation, there must be a mini­mum distance of 300 mm (see Fig. 4) to flammable components, furniture, decorations and curtains at the side! There must be no objects between the ebios-fire furniture and room ceiling (distance to ceiling > 1000 mm).
Fig. 4
2.7 COMBUSTION AIR SUPPLY
Your ebios-fire draws its combustion air from the room in which it is installed (dependent on indoor air). It must be ensured that there is a suf­ficient supply of fresh air to the room in which the fire is installed. It is possible that there is not a sufficient supply of fresh air if the windows and doors are sealed (e.g., in combination with energy saving measures). This can compromise your well-being and, under certain circumstances, also your safety and the combustion performance. Open a window to ensure a sufficient supply of fresh air.
(View may vary from your model)
Air gap approx. 7 mm (without cover plate)
Fig. 3
GB 9
3. OPERATING MANUAL
Read these installation and operating instructions carefully before installing and starting up your ebios-fire. All objects must be removed from the ebios­fire furniture (except for the burner unit).
Please follow the regulations for fire protection and dangerous goods!
3.1 GENERAL INFORMATION ON OPERATION
• Small children, elderly or infirm persons: As is the case with all open flames, it is expedient that you attach a protective fixture for these groups of persons (available as an accessory from specialist dealers) Risk of burn injuries! Never leave these groups of persons unattended near the ebios-fire when a fire is burning or has just been extinguished! Make these individuals aware of these risks.
• No combustible objects may be placed or laid on the free surfaces of the ebios-fire. Do not place items of clothing on the ebios-fire furniture to dry. Racks for drying clothing may only be placed outside the radiation area (Fig. 4)! Risk of fires!
• Thermal energy is released during the combustion process which causes the burner, the housing surfaces, the glass panes (depending on the model) and the protective glass panes to heat up. It is not permitted to touch these items without taking the necessary precautions (e.g., heat­resistant glove). Risk of burn injuries!
• Never leave the fire unattended whilst it is alight!
• With all models (Elipse and Quadra), ensure that the housing covers are closed and that the protective panes are inserted.
• It is recommended to open a window during operation.
• Several decorative ethanol fireplaces may only be operated if the fuel consumption rate of all devices together does not exceed 0.5 l/h and if additional measures are taken to ensure sufficient ventilation. In this context, please observe the table on page 6, under item 2.1. Technical data.
• The burner may only be operated with the burner mat and these wicks. It is not permitted to change the number of wicks, the wick material or the burner mat.
• The ebios-fire appliances must not be modified.
• This is merely a decorative fireplace for use in the home and is not intended for heating or continuous operation! Nevertheless, it should be taken into account that heat (approx. 3 kW) is generated as a by­product of the combustion process. Amongst other things this can cause increased heating in the room where the fireplace is installed.
• There should never be any fuel in the tank and the cover must always be placed on the burner when the latter is not in use.
• The burners are designed for the fuel to be burnt until all gone. If you only wish to enjoy the flames for a short period of time, use a corre­spondingly smaller amount of fuel. If you wish to take the burner out of operation prematurely, place the cover on the burner with the aid of the grip stick. After shutting down the burner, always allow at least 1 hour
• The burner must NOT be filled when warm or alight and must NOT be filled via the burner channel! DANGER TO LIFE!
GB 10
GB
• The handling of fuel in the vicinity of the hot or burning device is associ­ated with significant risks and is not permitted!
• Only fill the burner via the filling opening and never via the burner chan­nel! (see Fig. 1)
• Should you accidentally spill ethanol, clean this up immediately and before lighting the burner!
• Please note that the luminosity of the flame can decrease to such an extent that the flame is no longer clearly visible. Make children and others in the home aware of this.
• Minimum waiting time between extinguishing and refilling the burner = 1 hour!
• Do not smoke when handling fuel and operating the ebios-fire.
Failure to follow these basic rules can result in uncontrolled ignition or even explosions!
3.2 FIRE PROTECTION
Please note: In the radiation area Fig. 4 (in the area of the flames/furniture) the flammable components and furniture within 1000 mm upwards and 300 mm to the sides must be fitted with ventilated radiation protection on both sides.
There must be no flammable objects (decora­tions, clothing etc.) in the radiation area. In order to guarantee sufficient thermal insula­tion, there must be a minimum distance of 300 mm to flammable components at the side, furniture, decorations and curtains! There must be no objects between the fireplace and room ceiling (distance to the ceiling >1000 mm)!
300 mm
3.3 FUEL
Bioethanol (chemical formula C2H6O) with an ethanol content of 96.6% is used as the fuel. It is available from your specialist dealer. It is a dangerous substance as per ADR: Class 3 PG II, UN 1170.
Under no circumstances should other fuels such as petrol, spirit or similar flammable liquids be used. Do not mix the fuels together or with other substances. The burners may only be operated using the prescribed fuel otherwise the warranty will be rendered void and the device may be unsafe to operate.
Ethanol is a highly flammable liquid which must be stored well sealed, pro­tected from light and away from sources of fire. It is permitted to store max. 5 l in the living space and max. 20 l in the cellar. Keep bioethanol out of the reach of children. For your safety only fill the burner just before use to prevent it from being ignited unintentionally or by unauthorised persons and to also stop the fuel from evaporating.
Please note that ethanol is used exclusively for combustion and it not suit­able for consumption. Supervise your children! If swallowed consult a doctor immediately and present the fuel label.
GB 11
3.4 STARTUP
The ebios-fire devices are supplied with empty burners to prevent any ethanol from flowing out or evaporating during transit. Ensure (particularly before being put into use) that there is no fuel in the safety container.
3.4.1 STARTUP OF THE MODELS ELIPSE AND QUADRA
Proceed as follows:
1. Ensure that the air supply is sufficient. (see 2.7)
2. Make sure that the burner has gone out and has cooled down fully
(minimum waiting time after being extinguished = 1 hour).
3. The burner remains in the housing when being refilled. For this re-move
the protective panes and then open the housing cover.
4. Check the tank content.
5. Make sure that the cover plate is placed on the burner and covers the
burner mat.
6. Use a wrench to open the filling screw.
7. Insert the funnel into the filling opening and pour in a maximum of 2.6
l of bioethanol.
GB 12
GB
8. The fill level indicator shows the maximum permitted fill level. The maxi­mum fill level is achieved once the red fill level ball floats to the top.
9. Take the bottle to wet the burner. (Fig. Similar) Guide bottle with the opening into the tank opening until it protrudes right into the fuel. Press the bottle together so that the air escapes and the fuel is sucked up when it is released. Wait until the bottle returns to its original shape.
10. Seal the filling plug securely using the wrench.
11. Close the housing cover on the device and ensure that the cover does not extend into the flame area and instead maintains a uniform distance from the burner channel (depending on model, refer to Fig. 2 or Fig. 3). Then insert the protective panes.
12. Insert the cold hand to grip the cover plate and lift it off.
13. Wet the burner fleece with fuel using the bottle which has just been filled.
GB 13
14. Put the bottle down to one side.
15. Wait for approx. 30 seconds with ignition to enable the wick to be-come fully impregnated with ethanol.
16. Ignite the fire on the side of the burner mat and step back from the flames. It may take a few minutes until uniform flames appear.
Should you ever pour in too much fuel and cause the burner to overflow, the ethanol collects in the safety container. Empty this immediately and
before lighting the burner. Clean the surface of the burner until it is dry and completely free of ethanol.
3.5 REFILLING THE BURNER
The burner must NOT be filled when warm or alight and must NOT be filled via the burner channel! DANGER TO LIFE!
Proceed as follows to refill:
1. Ensure that the air supply is sufficient. (see 2.7)
2. Make sure that the burner has gone out and has cooled down fully (minimum waiting time after being extinguished = 1 hour).
3. The burner remains in the housing when being refilled. For this remove the protective panes and then open the housing cover.
4. Check the tank content.
5. Make sure that the cover plate is placed on the burner and covers the burner mat.
6. Use a wrench to open the filling screw.
Minimum waiting time between extinguishing and refilling the burner = 1 hour!
Please also leave the protective panes which may still be hot on the device during this time! Risk of burn injuries!
The burners are designed for the fuel to be burnt until all gone. If you only wish to enjoy the flames for a short period of time, use a correspondingly smaller amount of fuel. If you wish to take the burner out of operation prematurely, place the cover on the burner with the aid of the grip stick.
7. Insert the funnel into the filling opening and pour in a maximum of 2.6 l of bioethanol. (max. 1.2 litres on the Mini models)
GB 14
GB
8. The fill level indicator shows the maximum permitted fill level.The maxi­mum fill level is reached when the bioethanol runs out of the slit (see arrow) into the reflector curve.
Should you ever pour in too much fuel and cause the burner to overflow, the ethanol collects in the safety container. Empty this immediately and before lighting the burner. Clean the surface of the burner until it is dry and completely free of ethanol.
To ignite the burner, follow the steps 9-16 described in Point 3.4.1!
3.6 TAKING OUT OF OPERATION SAFELY
If you wish to take the burner out of operation prematurely, place the cover on the burner with the aid of the grip stick. Insert the grip stick to grip the cover plate and then cover this over the burner channel.
4. CLEANING AND CARE
The ebios-fire furniture may only be cleaned when cold.
4.1 CLEANING CLADDING PARTS
• Wait until the device has cooled down before cleaning (at least 1 hour)!
Decorative metal surfaces and the cladding parts can be cleaned with
a moist cloth (do not use a microfibre cloth!).
Glass surfaces can be cleaned with a standard glass cleaner and a soft
cloth (do not use a microfibre cloth!).
Stainless steel surfaces can be cleaned with a standard stainless
• steel cleaning agent. Only use in the direction of the finish!
Remove any dust on and below the ebios-fire furniture regularly as dust particles can burn or char. This can cause dirt in the room and on the furnishings where the fire is installed.
GB 15
5 MAINTENANCE/TROUBLESHOOTING
5.3 UNPLEASANT ODOURS
• The wick and burner fleece must be visually inspected at regular inter­vals. The material can be easily damaged. As such, the burner fleece should not be folded, bent or similar. It is not permitted to change the burner mat or wick.
• The burner mat must be replaced after approx. 380 service hours (corre­sponds to a fuel throughput of around 190 l bioethanol). Please contact your specialist dealer.
• Only use our original spare parts.
• The tank seal must be examined occasionally for cracks or brittleness and should be replaced if necessary.
• Please contact your specialist dealer should you have any questions.
5.1 FURNITURE AND GLASS (DEPENDING ON THE
DESIGN) BECOMES SOOTED HEAVILY, RAPIDLY AND UNEVENLY
If this did not occur from the very start, please check the following points:
• Has the correct fuel been used? (see 3.3).
• Cladding/cover correctly positioned? (see 2.5)
5.2 FIRE IS DIFFICULT TO IGNITE
If this did not occur from the very start, please check the following points:
• Is there fuel in the burner? (see 3.5)
• Have you wetted the ignition mats? (see 3.4)
• Has the correct fuel been used? (see 3.3).
• Fuel in a burner which is not in use? (see 3.1)
• Cover plate in position? (see 3.1)
• Fuel was spilt when filling the device? (see 3.5)
5.4 APPEARANCE OF FLAMES CHANGES
• Is the burner fleece damaged? (see 5)
• Has the correct fuel been used? (see 3.3).
• Were all safety distances observed? (3.2)
• Is the site of installation sufficiently ventilated? (2.7)
• Is the installation site protected from transverse ventilation? (2.4)
If the appearance of the flames changes noticeably, especially if the flames begin to extend above the protective pane, stop using the device (see 3.6) and notify the specialist dealer.
5.5 SPILT ETHANOL IGNITES
If spilt ethanol is ignited, attempt to put out the flames immediately. Use, for example, foam fire extinguishers with alcohol-resistant foam or suitable fire blankets. We recommend that such extinguishing agents be kept at the ready. Should it not be possible to extinguish the fire rapidly, the fire service must be notified immediately and their instructions followed.
GB 16
GB
6. GENERAL WARRANTY CONDITIONS
6.1 SCOPE OF APPLICATION
These standard warranty terms apply for the contractual relationship between the manufacturer, Spartherm Feuerungstechnik GmbH, and the dealer/distributor. They are not congruent with the contractual and warranty terms which the dealer/distributor offers his customers in individual cases.
6.2 GENERAL INFORMATION
This product has been manufactured in compliance with current standards of quality control. The materials used have been carefully selected and - like the production process - are subject to on-going quality control. Specialist knowledge is required when assembling and installing the product. The product must, therefore, only be installed and started up by specialist technical staff, in compliance with current statutory provisions.
6.3 WARRANTY PERIOD
The standard warranty terms only apply within Germany and the European Union. The warranty period and scope of the warranty are ensured within the framework of these conditions outside the statutory warranty which remains unaffected.
Spartherm Feuerungstechnik GmbH grants a 24-month warranty on ebios­fire devices.
Spartherm Feuerungstechnik GmbH grants a 6-month warranty on wearing parts in the fire area, e.g., wicks, burner mats, seals and glass ceramic.
6.4 REQUIREMENTS FOR THIS WARRANTY TO BE EFFECTIVE
The warranty period shall begin on the date, on which the product is deliv­ered to the dealer / distributor. Invoices or delivery notes may be used as confirmation of the warranty commencement date. The warranty certificate for the product must be presented by the claimant upon making a warranty claim. Spartherm Feuerungstechnik GmbH is not obliged to satisfy any claim if such documentation is not presented.
6.5 EXCLUSION OF WARRANTY
This warranty does not cover:
• component wear
• Wick/burner mat due to thermal stress
• the fireplace surfaces: Discolouration of the finish or on the galvanic
surfaces of the furniture and/or burner which are a result of thermal stresses or overloading
• the glass panes: contamination, due to soot or other burnt-on combus-
tion materials and visual deterioration due to thermal loading.
• Use of unsuitable or non-designated fuel.
• We recommend bioethanol from Spartherm Feuerungstechnik GmbH
with a concentration in excess of 96% for your ebios-fire device.
• incorrect transportation and/or incorrect storage:
• inappropriate or careless handling of fragile components, such as glass
or ceramics
• improper operation and/or use
• incorrect filling of system
• lack of maintenance
• incorrect set-up/installation of device
• failure to comply with Installation and Operating Manual
• technical modifications made to the appliance by third parties
GB 17
6.6 ELIMINATION OF DEFECTS / REPAIR
6.9 LIABILITY
Independent of any statutory provisions acknowledged as taking precedence over the terms of this warranty, all necessary repair works resulting from material or manufacturing defect shall be carried out free-of-charge in the context of this warranty and shall not invalidate the remaining provisions of the warranty.
Within the scope of this warranty promise Spartherm Feuerungstechnik GmbH reserves the right to either remedy the fault or replace the device free of charge. The elimination of defects shall take precedence. The terms of this warranty shall not extend to any damage or compensation not covered by statutory provisions.
6.7 EXTENSION OF THE WARRANTY PERIOD
The warranty period shall automatically be extended, where claims made in respect of these warranty provisions result in the repair or replacement of defective equipment.
6.8 SPA RE PARTS
Only the manufacturer’s own components, or replacement parts recom­mend-ed and approved by the manufacturer, shall be used for appliance servicing and repair.
Damages and claims for compensation which are not the result of deliv­ery of a defective appliance from Spartherm Feuerungstechnik GmbH are excluded and are not part of this warranty promise. The above shall not include claims made in respect of statutory legal requirements.
6.10 FINAL COMMENTS
In addition to these warranty conditions and our commitment to them, our dealers and contractual partners are pledged to assist you in both word and deed. It is expressly recommended to have ebios-fire products checked regularly by a stove fitter/specialist dealer.
We reserve the right to make alterations to the technical data contained herein and accept no liability in respect of any errors made.
GB 18
We reserve the right to make alterations to the technical data contained herein and accept no liability in respect of any errors made.
NOTES
GB
GB 19
SPARTHERM
DIE WELTMARKE FÜR IHR WOHNZIMMER
The Global brand for your living room | La référence mondiale pour votre salon | Il marchio mondiale per il vostro soggiorno
La marca mundial para su salón | Het merk van wereldformaat voor uw woonkamer | Światowa marka do Państwa salonu
Торговая марка № 1 для Вашего дома
D Ihr Fachhändler | UK Your specialist dealer | F Votre revendeur spécialisé
IT Il vostro rivenditore specializzato | E Sus comercios especializados
NL Uw vakhandelaar | PL Państwa sprzedawca | РУС Ваш дилер
SPARTHERM Feuerungstechnik GmbH · Maschweg 38 · D-49324 Melle
Phone +49 (0) 5422 94 41-0 · Fax +49 (0) 5422 9441-14 · www.spartherm.com
GB 20
A1-SP-GB/0.000/02/2018
Loading...