11. TECHNICA L DATA
General data
Nominal he at outpu t kW (clos ed opera tion)
Thermal output range kW
Efficiency %
Required chimney diameter (mm)
Flue gas co nnecti on: Ø mm
Possibl e flue gas co nnecti on Ø mm
Weight (app rox.) kg
Required mi nimum cross-sectio n for supply and recirc ulating air (with WL M) c m
2
Required min imum cross-sectio n for recirculating and s upply air (without W LM) cm
2
Testing and va lues
non-self-closing combustion chamber door (Design A)
self-closing combustion chamber door (Design A1)
Operation with open combustion chamber door
Level 2 BlmS chV [Ordinance in the I mplementation of th e Federal Immission C ontrol Act]
15a B VG
Operation with open
combustion chamber
(multiple allocation
not permitted)
Mass flo w of flue gas g /s
Flue gas temperature °C
Flue gas te mperatu re behind th e NSH F °C
Combustion air requirement m
3
/h
Required supply pressure: in Pa
Operation with
closed combustion
chamber (multiple
allocation permitted)
Mass flo w of flue gas g /s
Flue gas te mperatu re °C (on the f lue gas out let)
Required supply pressure: in Pa
CO
2
%
Required diameter after M-FeuVo. cm
Combustion air requirement m
3
/h
Heating chamber
distance
to the heating chamber wall cm
To the setup fl oor cm
Heat insulation
(example rock wool
mattin g to AGI- Q
132)
Setup fl oor cm
Mounting wall cm
Side wall cm
Stud wall w ith a wall t hat must be p rotecte d cm
Substitute insulation
material, calcium
silicate
Setup fl oor cm
Mounting wall cm
Side wall cm
Heat distribution
Convection %
Viewing panel %
H
2
O %
Mini
S
Mini
Sh
Speedy
1V 51
Speedy
1V 57
Speedy
1V 51
NSHF
Speedy
1V 57
NSHF
Speedy
1V 51
(Export)
Speedy
1V 57
(Export)
7.0 7.0 9.0 9.0 10.0 10 .0 14.5 14.5
4. 9-9,1 4.9 -9,1 6. 3-11,7 6. 3-11,7 7.0 -13 ,0 7.0 -13 ,0 10.2-18 ,9 10.2-18 ,9
>78 >78 80 80 > 8 0 > 80 > 78 >78
180 18 0 200 200 200 200 200 200
180 18 0 200 200 200 200 200 200
- - 180 18 0 18 0 180 180 180
205 205 195 200 195 200 195 200
700 70 0 70 0 700 700 - 700 700
810/ 890 810/ 890 1420/ 1710 142 0/1710 1420 /1710 14 20/17 10 1420 /1710 14 20/17 10
-
- - - - - -
* *
* *
17. 8 1 7.8 - - - - - -
230 230 - - - - - -
- - - - - - - -
86.4 85.5 - - - - - -
12 12 - - - - -
8.8 8.8 7.2 7. 5 9.3 8.8 10.9 10 .2
290 290 3 42 299
391
(163 behi nd NS HF)
392
(170 behind NSH F)
346 327
14 14 12 12 12 12 12 12
7.9 7. 9 12 .2 11.7 9.4 10 .0 12.2 13.2
15 15 15 15 15 15 15 15
27. 6 2 7.6 21 .1 23.4 29.8 2 7.7 36.8 34.0
9 9 10 10 10 10 10 10
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
9 8 16 16 16 16 16 16
9 8 16 16 16 16 16 16
10 10 10 10 10 10 10 10
0 0 0 0 0 0 0 0
7 6 12 12 12 12 12 12
7 6 12 12 12 12 12 12
58 58 64 64 64 62 64 62
42 42 36 36 36 38 36 38
0 0 0 0 0 0 0 0
Changes and mistakes reserved
* Fulfils 15a 2 015 only with AT ha nd piece, a ttenti on: flue ga s connec tion + 160 mm
*** Va lues were no t availabl e at the time of p rinting .
*** Deviating insulation guidelines apply for GET fireplace inser ts.
This can b e obtaine d from the s eparate G ET manual.