2.2. TECHNICAL DATA
The following data have been taken from the test report and relate to test
conditions.
Stove a1/a2/a3/a4 a4 H20 a5 a7 a8
RLA RLU RLA RLU RLA RLA RLA
Type of fuel Logs
Hot water output (kW*) - - 5,2 5,2 - - -
Heat output to room (kW*) 5,9 5,9 2,9 2,9 7,0 5,9 5,9
Wood consumption (kg/h) 1,9 1,9 2,2 2,2 2,2 1,9 1,9
Nominal heat output (kW) 5,9 5,9 8,0 8,0 7,0 5,9 5,9
Heat output range (kW) 4,5-7,7 4,5-7,7 5,6-10,4 5,6-10,4 4,9-9,1 4,5-7,7 4,5-7,7
Corresponding wood
consumption (kg/h)
1,4-2,4 1,3-2,5 1,2-3,0 1,5-2,7 1,5-2,8 1,4-2,4 1,4-2,4
Efficiency (%*) > 80 > 80 > 80 > 85 > 78 > 80 > 80
CO content at 13% O
2
(mg/Nm3)
< 1250 < 1250 < 1250 < 1250 < 1250 < 1250 < 1250
Dust content (mg/Nm3) < 40 < 40 < 40 < 40 < 40 < 40 < 40
Flue gas temperature at stack
1
(°C)
350 350 150
1
150 1305 318 300
Manometric pressure (mbar**) 0,12 0,12 0,12 0,12 0,12 0,12 0,12
Flue gas mass flow (g/s) 5,1 5,1 7,6 7,6 6,8 5,1 5,8
Combustion air demand (m
3
/h) 19 18,8 26 26,1 23,5 17,8 17,8
Weight according to model (kg)
from
180-335
from
180-335
approx
230
approx
230
approx
225 /
240 /
255
170-205 200-300
Permissible operating pressure
(bar)
- - 3,0 3,0 - - -
Stove a1/a2/a3/a4 a4 H20 a5 a7 a8
RLA RLU RLA RLU RLA RLA RLA
Max. permissible flow temperature (°C)
- - 105 105 - - -
Max. operating temperature (°C) - - 95
2
95 2- - -
Minimum return temperature (°C) - - 60 60 - - -
Water output resistance at 650
l/h (mbar)
- - 26 26 - - -
Minimum water throughput of
thermal discharge safety device
(litres)
- - 900 900 - - -
Water capacity (litres) - -
approx 29approx
29
- - -
Flow and return connection (IG) - - ¾¨ ¾¨ - - -
Safety heat exchanger inlet and
drain connection (IG)
- - ½¨ ½¨ - - -
Minimum distances from combustible building components
Rear (mm) 100 100
3
100 100 3200 150 150
Sides (mm) 150 150
3
100 100 3200 150 100
Top (mm) 500 500
3
500 500 3500 500 500
Radiant area (mm) 800 800
3
800 800 3800 800 800
Requirements
BImSchV Stages 1 + 2 yes yes yes yes yes yes yes
EN 13240 yes yes yes yes yes yes yes
* The values shown represent the mean over a combustion period.
These values relate to type test conditions.
** Depending on the stove, negative pressures greater than 20-25 Pa may interfere with correct operation,
resulting in increased sooting up of the viewing panes or operating noise.
1
Due to the low flue gas temperature of the ambiente a4 H2O, a suitable chimney system (insensitive to
moisture) is required, such as the Alkon made by Raab.
2
The thermal discharge safety device integrated into the heating system will trigger at a flow temperature
of approx. 95°C.