Self-Diagnostic Error Codes
The SpaPower 600controller has extensive selfdiagnostic capabilities. In theevent of aproblem itwill indicate an errornumber according to the natureof the problem.The errornumbers and theirmeanings are listed below. Note: Whenin anerror state thealarm canbe muted bypushing theAIR/AUX button.
SP600 User Guide (AC&BC Models).pdf
Booklet Part Number 916317
8th Oct 2004
Error 1(H20)
Error 2 - Not Used. With any Error 3-8, spa operation will stop and not continue until the controller is reset. (Switched offand on again atthe main power supply)
Error 3
Error 4
Error 5
Error 6
Error 7
Error 8
- PrimeFailed
This is not necessarily a problem with the SP600 itself, but indicates thatno water is being detected in the heater housing. Prime failed is a special case in that it can be recovered from by pushing a button. A push of the pump button will run the pump for 60 seconds totry toget water tothe heater.If successful normaloperation willresume. If unsuccessful,Error 1(H20) will beindicated on the displayagain.
- StuckButton
This error indicates thatone of the buttons in the touchpad is stuck or has been helddown for more than one minute.This may be caused by thepool cover pressing onthe touch pad, or watergetting into the touch pad or bydamage to the touchpad or its cable. Tryto reset thespa. Ifthere is stilla problemthen contact yourspa poolreseller.
- NoWater Sensor
This error indicates a problem with the optical water sensor in the heater. The problem may by caused by the sensor being disconnected orby damageto the sensor. Try toreset thespa. If thereis stilla problem thencontact yourspa pool reseller.
- Overtemperature
This error indicates thatthe digital temperature sensor in theheater or pool has detected a temperatureof 45 C or more. This may not bea problem withthe SP600, itmay be causedby excessivepump use inhot weather, orpump failure.Turn off thespa and allow time forthe waterto cool. Ifthere isstill a problemthen contactyour spa poolreseller.
- ThermalCut OutTripped
This errorindicates that the safetyelectromechanical over temperaturecut out on theheater has operated.This is not necessarilya problem with theSP600. It may have occurredfrom an air lockaround the element, high temperaturesduring shipping, or failure of the pump.This automatic cutout will only resetonce the elementhas cooled belowabout 38 C. The unitmust then bereset before it will resumeoperation. (Switchoff and onat themains power supply).
- StuckRelay
This errorindicates aproblem with theheater controlcircuitry inside theunit. Contactyour spa poolreseller.
- NoTemperatureData
This error indicates a problem with the digital temperature sensor in the heater or pool wall or that both the in heater and in pool sensors areconnected. Check that onlyone sensor is connectedand that ithas not become disconnectedor damaged. Tryto reset the spa.If there isstill a problemthen contactyour spa poolreseller.
o
o
Congratulations on choosing the latest Spa Power 600 control system. This
controller makes use of the latest technology, including innovative optical and digital sensor designs. The greater variety of optional accessories, user-friendly touchpad and reliable components provide youwith the most sophisticatedcontroller in its class.
The Spa Power 600AC/BC usesa smallcirculation pump which runs 24hours aday, to circulate water through the filterand heater.The heater is always automatically controlled to maintain the water at the desired temperature as set by the user The user can leave the system to look after the spa and knowit willbeat thecorrect temperaturewhenever he orshe wantsto use it.
(see below).
Temperature Control
Adjusting Set Temperature
UP Increase the set temperature by 0.5 C per beep (Max = 41.5 C)
oo
DOWN Decrease the set temperature by 0.5 C per beep (Min = 10.0 C)
oo
The Spa Power 600AC/BC gives the user direct control of the pool temperature from the poolside control panel. Holding down the Up or Down button will adjust the temperature set point as shown on the digital readout. There is a slight delay before the buttons operate to reduce the risk of accidental adjustment. The pooltemperature willbe maintained veryclose tothe set temperature.
The displaynormally showsthe temperatureset point,unless theoptional inpool temperature sensoris fitted inwhich casethe sensed watertemperature isdisplayed. In eithercase thetemperature setpoint will bedisplayed whilebeingadjusted asdescribed above.
Default Display
37.0
Non-Default Display Value
The non-default display value (either sensed water temperature or temperature set point) can be checked ifnecessary bypressing the Up& Downbuttons simultaneously.
H20
JETPUMP
HEATER
AIR
ON
SPA POWER 600SPA POWER 600
37.0
Press both buttons simultaneously
Page 1 Page 6
If the optional time clock has been fitted, sleep mode is used to disable automatic temperature maintenance and filtration in order to reduce the heat contribution from the small circulation pump and extend the small circulation pump and (optional)ozone system life. Thesleep time setting is done using the digital time clock on the front of the control box (See below for setting instructions). The spawill wake fromsleep mode whenany button is pushed to allow it to beused manually as normal.If the spa is in use it will not enter sleep mode until 30 minutes after the last manual button push, even if the clock is calling for sleep mode. On wake up from sleep the system will run the Main pump for15 seconds andthen theblower for 15seconds to purgethe plumbing. This prevents any stagnant water from collecting in the pipes if the pool is not used foran extendedperiod.
To Set Current Time and Day
1. Pressthe button beforeuse. NOTE:This is optional. Itwill clearthe current timeand programsettings.
2. Holddown the button andpress the button untilthe correct dayis selected.Release both buttons.
3. Holddown the button andpress the buttonuntil the correcthour isset. Release bothbuttons.
4. Holddown the button andpress the button untilthe correctminute is set.Release bothbuttons.
5. Aftersetting theweekday and time,the secondswill reset automaticallyand theclock will beginkeeping time.
RESET
CLOCK DAY
CLOCK HOUR
CLOCK MIN
Sleep Time (Optional Timeclock)
To Set Programs
1. Press the button. "1ON" will appear at the left side of the display. This is the start time of the first programmed sleep block (thetime youwant the spato enterthe sleep mode).
2. Press the button toselect thedays on whichthis sleepprogram will operate.There are15 settings tochoose from.
3. Press the button toset thehour of thedesired timeto enter sleepmode.
4. Press the button to setthe minutesof the desiredtime toenter sleep mode.
5. Now thestart time hasbeen set, pressthe button again."1OFF" will appearon the display. Thisis the endtime of thefirst programmed sleepblock (thetime you wantthe spato resume normaloperation).
6. Repeat thesame procedure(2 to 4above) untilthe "1OFF" timeis set.(
7. Yourtimer givesyou up to8 differentprogrammable periods. You can useall 8settings , oras fewas you like.
8. ToReview yourset programs pressthe buttonand keep pressingit toadvance through eachsetting.
TIMER
DAY
HOUR
MIN
TIMER
TIMER
Be carefulto setthe same daysas usedin the "1ON"time).
IMPORTANTNOTE: The"MANUAL" button onthe clockcan be usedto overridethe programmed sleepsettings. Itis very importantto ensure that theclock is set to "AUTO"so that the programmedtimes can operate. If theclock is manually set toON then the pool will stay in sleepmode and THE WATER WILLGO COLD. If it isleft in "OFF" then thepool will not enter thesleep mode. The clock does not returnto "AUTO"by itself.
NOTE: If the“MANUAL” button on theclock is pushed the spa will notreturn to the programmedsettings until the next programmed time.
MANUAL
D
A
Y
C
L
O
C
K
T
I
M
E
R
H
O
U
R
M
I
N
P
ON
9:3139
ON AUTO OFF
MON
ON
H
E
A
T
HEATH
E
A
T
HEAT
P
U
M
P
PUMP
A
U
T
OAUTO
AIRAIR
P
U
M
P
PUMP
A
U
T
OAUTO
AIRAIR
37.0
Loading...
+ 2 hidden pages