Spa-Quip SP601-15T, SP601-20, SP601AU-15, SP601AU-15T, SP601-20T User Manual

...
AUTO
PUMP
HEATER
AIR
ON
<TEMP SET>
HOLD BUTTON
PRESS BOTH
TO READ ACTUAL
HEATHEATHEATHEAT
PUMP
AUTO
AUTO
AIR
PUMP
AUTO
AUTO
AIR
ONON
User’s GuideUser’s Guide
Models Covered ByThis User’s Guide :
SP601-15 SP601-15T SP601AU-15 SP601AU-15T
SP601-20 SP601-20T SP601AU-20 SP601AU-20T
SP601-30 SP601-30T SP601AU-30 SP601AU-30T
SP400P SP400PAU-10 SP400PAU-15
Contents
1 Touch Pads......................................................................................................................................... Pg 1
2 Temperature Control............................................................................................................................ Pg 2
2.1 - Adjusting Set Temperature............................................................................................... Pg 2
2.2 - Non Default Display Value............................................................................................... Pg 2
2.3 - Heating Mode Selection(24hr circulation pump not fitted)............................................... Pg 2
3 Pump Operation.................................................................................................................................. Pg 3
3.1 - Pump 1 (Single speed pump, no 24hr circulation pump fitted)........................................ Pg 3
3.2 - Pump 1 (Single speed pump, 24hr circulation pump fitted)............................................. Pg 3
3.3 - Pump 1 (Two speed pump,no 24hr circulation pump fitted)............................................ Pg 4
3.4 - Pump 1 (Two speed pump, 24hr circulation pump fitted)................................................ Pg 4
4 Auxiliary/Air Button.............................................................................................................................. Pg 5
4.1 - Adjustable Speed Mode(SPVSB only)............................................................................. Pg 5
5 Light Operation.................................................................................................................................... Pg 6
5.1 - Adjustable Colour Mode(SPVCL only...............................................................................Pg 6
5.2 - IndicatorLlight................................................................................................................... Pg 6
6 Auto Sanitisation.................................................................................................................................. Pg 7
6.1 - No 24hr Circulation Pump Fitted...................................................................................... Pg 7
6.1.1 - Adjusting Minimum Filtration...........................................................................Pg 7
6.1.2 - Clean Up Cycle.............................................................................................. Pg 7
6.2 - 24hr Circulation Pump Fitted........................................................................................... Pg 7
6.3 - My Spa Is Too Hot In Summer......................................................................................... Pg 7
7 Sleep Timer......................................................................................................................................... Pg 8
7.1 - To Set Current Time And Day........................................................................................... Pg 8
7.2 - To Set Programs...............................................................................................................Pg 8
8 Self Diagnostic Error Codes................................................................................................................ Pg 9
Section
HEATHEAT
PUMP
AUTO
AIR
PUMP
AUTO
AIR
ONON
AUTO
PUMP
HEATER
AIR
ON
<TEMPSET>
HOLDBUTTON
TOADJUST
PRESSBOTH
TOREAD ACTUAL
The green Pump indicator light will appear on the touch padwheneverthepumpisrunning,inboth auto and manual use mode. If this light is flashing, the spa is in Sleep Mode.
Pump LED
The red Heater indicator light will appear on the touchpad whenever the heater element is on, in both auto and manual use mode. For safety the heater is always automatically controlled. Usually switching on the air blower accessory will cause the heater to switch off (loadshedding). This is inorder to keep the totalpower load to a safelevel. If this light isflashing the system hasan error
Heat LED
(see section8).
H20 LED (24hr circulation pump fitted)
The yellow H20 light indicates if waterispresentintheheater. Ifnowaterisdetectedthenthe LED will flash and the unit will not operate except to run the circulation pump to try to get water to the heater. If no water reaches the heater for one minute then an H20 error will occur. If this happens then pushing the pump button will run the circulation pump for another minute.
Page 1
Congratulations on choosing the latest Spa Power control system. This controller makes use of the latest technology, including innovative optical and digital sensor designs. The greater variety of optional accessories, user­friendly touchpad and reliable components provide you with the most sophisticated controller in its class.
Heat LED
Pump LED
Auto/H20 LED
Aux/Air LED
Aux/Air/Pump Button
Up Button
Down Button
Heat LED
Pump LED
Auto/H20 LED
Aux/Air LED
Pump Button
Pump Button
Aux/Air/Pump Button
Up Button
Down Button
37.0
1 Touch Pads
Auto LED (No 24hr circulation pump fitted)
The yellow Auto indicator light will appear on the touch pad whenever the system is in full automatic control mode. In this mode the system automatically activates the pump and heater to filter the water and maintain the set water temperature. If this light is flashing the water sensor is not detecting any water.
Aux/Air LED
The Aux/Air indicator LED will appear on the touchpad whenever the Aux/Air button is pushed and conversly will disapear when the button is pushed again. Note: If the spa does not have a load connected to the controller the LED will still operate as described above.
37.0
H
E
A
THEATH
E
A
THEAT
PU
M
P
PUMP
A
U
T
OAUTO
AIRAIR
PU
M
P
PUMP
A
U
T
OAUTO
AIRAIR
ONON
AUTO
PUMP
HEATER
AIR
ON
<TEMPSET>
HOLDBUTTON
TOADJUST PRESSBOTH
TOREAD ACTUAL
H
E
A
THEATH
E
A
THEAT
P
U
M
P
PUMP
A
U
T
OAUTO
AIRAIR
P
U
M
P
PUMP
A
U
T
OAUTO
AIRAIR
ONON
AUTO
PUMP
HEATER
AIR
ON
<TEMPSET>
HOLDBUTTON
TOADJUST
PRESSBOTH
TOREAD ACTUAL
H
E
A
THEATH
E
A
THEAT
P
U
M
P
PUMP
A
U
T
OAUTO
AIRAIR
P
U
M
P
PUMP
A
U
T
OAUTO
AIRAIR
ONON
AUTO
PUMP
HEATER
AIR
ON
<TEMPSET> HOLDBUTTON TOADJUST PRESSBOTH
TOREADACTUAL
Page 2
The Spa Power controller automatically controls the pump and heater to filter the water and maintain it at the desired temperature set by the user (see below).The usercanleavethesystemtolookafterthespa and know it will be at thecorrect temperaturewhenever he orshe wants to useit.
2 Temperature Control
2.1 Adjusting Set Temperature
UP Increase the set temperature by 0.5 C per beep (Max = 41.5 C)
oo
DOWN Decrease the set temperature by 0.5 C per beep (Min = 10.0 C)
oo
The Spa Power controller gives the user direct control of the pool temperature from the poolside control panel. Holding down the Up or Down button will adjust the temperature set point as shown on the digital readout. There is a slight delay before the buttons operate to reduce the risk of accidental adjustment. The pool temperature will be maintained very closeto theset temperature.
The display normally shows the temperature set point, unless the optional in pool temperature sensor is fitted in which case the sensed water temperature is displayed. In either case the temperature set point will be displayed while being adjustedas describedabove.
Default Display
37.0
2.2 Non-Default Display Value
The non-default display value (either sensed water temperature or temperature set point) can be checked if necessary by pressingthe Up& Down buttonssimultaneously.
Press both buttons simultaneously
In addition to the temperature setting the user can select the preferred heating mode. The two available heating modes are... 1/ Demand Heating (displayed as Ht.d).This is the default setting in which the pump and heater will come on automatically whenever thetemperature dropsslightly below theset point. 2/ Filtration Only Heating (displayed as Ht.F).In thismode thepump andheater will come on automatically no more than once per hour to filter and heat the water. This mode is provided as an option for those who prefer to limit the natural cycling ofthe system. To select the heating mode first press the Pump and Down buttons simultaneously to display the current heating mode, then pressand holdthe Up orDown buttons to changemodes.
2.3 Heating Mode Selection (24hr circ pump not fitted)
Press both buttons simultaneously
Press Up or Down buttons to toggle between heating modes.
37.0
37.0
Loading...