Installer: Leave this guide with the homeowner
Homeowner: Keep this guide for future reference
Under Cabinet Range Hood
SPAGNA VETRO
Rev. 1032u.3a
Page 2
Page 3
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The installation in this manual is intended for qualied installers, service technicians or persons with •
similar qualied background. Installation and electrical wiring must be done by qualied professionals and in accordance with all applicable codes and standards, including re-rated construction.
DO NOT• attempt to install this appliance yourself. Injury could result from installing the unit due to
lack of appropriate electrical and technical background.
Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any •
parts for installing, cleaning or servicing.
Activating any switch ON before completing installation may cause ignition or an explosion.•
Due to the size and weight of this range hood, two people installation is recommended.•
To reduce the risk of re, electric shock, or injury to persons:
For general ventilating use only. • DO NOT use to exhaust hazardous or explosive materials and vapors.
The combustion air ow needed for safe operation of fuel-burning equipment may be affected by this •
unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society of
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre-•
vent power from being switched ON accidentally.
Clean grease laden surfaces frequently. To reduce the risk of re and to disperse air properly, make •
sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics
or garages.
Ducted fans MUST always be vented to the outdoors.•
Use only metal ductwork and this unit MUST be grounded.•
Sufcient air is needed for proper combustion and exhausting of gases through the duct to prevent •
back drafting.
When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid-•
den utilities.
All electrical wiring must be properly installed, insulated and grounded.•
Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease re.•
Check all joints on duct work to insure proper connection and all joints should be properly taped.•
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the •
vendor.
To reduce the risk of a stove top grease re:
Keep all fan, bafe, spaces, lter, grease tunnel, oil container and grease-laden surfaces clean. Grease •
should not be allowed to accumulate on fan, bafe, spaces, lter, grease tunnel and oil container.
Always turn range hood ON when cooking at high heat or when cooking aming foods. •
Use high settings on cooking range only when necessary.•
Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers •
that may ignite. Heat oils slowly on low or medium settings.
Page 1
Page 4
Important Safety Notice
Read all Instructions before Installing and operating this appliance
Clean ventilating fan frequently.•
Always use appropriate cookware and utensils size.•
Always use cookware appropriate for the size of the surface element.•
To reduce the risk of injury to persons in the event of a stove top grease re:
SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn OFF the burner. •
BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the ames DO
NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local
emergency service immediately.
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.•
Use an extinguisher ONLY if:•
You know you have a Class A, B, C extinguisher, and you already know how to operate it.•
The re is small and contained in the area where it is started.•
The re department is being called.•
You can ght the re with your back to an exit.•
To reduce the risk of injury to persons in the event of a gas leaks:
Extinguish any open ame.•
DO NOT turn on the range hood fan or any type of ventilator.•
DO NOT turn on the lights or any type of appliance.•
Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and re •
department, or dial your local emergency service immediately.
Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.
All safety messages will follow the safety alert symbol and the word “WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
The manufacturer and/or distributor/reseller further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
The manufacturer and/or distributor/reseller will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range
hood.
UC200 Series Under Cabinet Range Hood (vary with model)
Aluminum Filters
(Pre-Installed)
for 1900 & 2000 Class for 4100 Class for 1800 Class
Rectangular Exhaust/Vent Adapter
(For vertical or horizontal venting)
Round Exhaust /VentAdapter
(For vertical venting)
Qty: 4 PCS
(For sheet rock only)
Qty: 4 PCS
Charcoal lter
(Optional re-circulating kit
available only on UC200-
2000 Class)
Page 4
Page 7
Venting Requirements
Vent system must terminate to the outside •
(roof or side wall).
DO NOT terminate the vent system in an at-•
tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall •
caps.
Use metal/aluminum vent only. Rigid metal/•
aluminum vent is recommended.
DO NOT use plastic vent.•
Always keep the duct clean to ensure proper •
airow.
Calculate the following gures before instal-•
lation:
Distance from the oor to the ceiling.1.
Distance between the oor to the coun-2.
tertop/stove.
Distance between the countertop/stove 3.
to the range hood (recommend* 27” to
30”).
Height of hood and duct cover/cabinet.4.
For the most efcient & quiet operation:
A distance of 27” to 30” is recommended* •
between stove top and the bottom of range
hood.
It is recommended that the range hood be •
vented vertically through the roof through 6”
(15.3 cm) or bigger round metal/aluminum
vent work.
The size of the vent should be uniform.•
Use no more than three 90° elbows.•
Make sure there is a minimum of 24” (61 •
cm) of straight vent between the elbows if
more than one elbow is used.
DO NOT install two elbows together.•
The length of vent system and number of •
elbows should be kept to a minimum to provide efcient performance.
The vent system must have a damper. If •
roof or wall cap has a damper, DO NOT
use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints •
in the vent system.
Use caulking to seal exterior wall or roof •
opening around the cap.
Ceiling
Height
Cabinet
Height
Range
Hood
Height
Min: 27”
Max: 30”
36”
Counter
Top
Height & Clearance
Cabinet
Under Cabinet
Range hood
Countertop/Stove
* Due to different ceiling height congurations, rec-
ommended height may not be applicable.
Page 5
Page 8
IMPORTANT:
A minimum of 6” round (standard for this range hood) or 3-1/4 x 10” rectangular duct (purchased separate-•
ly) must be used to maintain maximum airow efciency.
Always use rigid type metal/aluminum ducts if available to maximize airow when connecting to provided •
duct.
Please use • Duct Run Calculation below to compute total available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase •
duct size from 6” to 7” or 8”. If a reducer is used, install a long reducer instead of a pancake reducer. Reducing duct size will restrict airow and decrease airow, thus reduce duct size as far away from opening as
possible.
If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.•
Minimum mount height between stove top to hood bottom should be no less than 27-inch*.•
Maximum mount height between stove top to hood bottom should be no higher than 30-inch*.•
It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat •
damage and re hazard; while hoods mounted too high will be hard to reach and will loose its performance
and efciency.
If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood •
mounting height above range.
* Due to different ceiling height congurations, recommended height may not be applicable.
Minimum Duct Size:
Round - 6” minimum•
Rectangular - 3-1/4 x 10” minimum (requires a provided 3-1/4x10” adaptor)•
Calculating Vent System Length
To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system
from the recommended maximum duct run.
Duct Run Calculation:
Recommended maximum run
6” or 3-1/4 x 10” duct50 ft
Vent piece deduction
Each 90º elbow used9 ft
Each 45º elbow used5 ft
Each 6” to 3/14 x 10” transition used7 ft
Side wall cap with damper0 ft
Roof cap0 ft
Duct Run Calcuation example:
One roof cap, two 90º elbow, and one 45º elbow used:
0ft + 9ft + 9ft + 5ft = 23ft used.
Deduct 23ft from 50ft, 27ft maximum available for
straight duct run.
Page 6
Page 9
Venting Methods
IMPORTANT:
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or •
garages. All exhaust must be ducted to the outside.
Use metal/aluminum duct work only. •
Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.•
Use caulking to seal exterior wall or roof opening around the cap.•
Venting Methods:
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow may be needed.•
This range hood is factory set for vertical venting using round or rectangular vent adapter but can be con-•
verted to horizontal venting by swapping the round vent adapter on top with rectangular vent adapter behind
the range hood as shown below:
Option 1:
Recirculate venting
(available with 2000 Class only)
Type 1:
3-1/4 x 10-inch rectangular vent
adapter behind the range hood.
Option 2:
Horizontal wall venting
Side wall cap
Type 2:
3-1/4 x 10-inch rectangular vent
adapter on top of the range hood.
Option 3:
Vertical roof venting
Roof cap
Type 3:
6-inch round vent adapter on top
of the range hood.
Charcoal Filter Installation
NOTE: The charcoal lters are preinstalled if you purchased the range hood with re-circulating kit from us.
Remove aluminum lters on hood.1.
Position the charcoal lter onto the motor and turn until it locks. Re-install aluminum lters.2.
Charcoal lters must be replaced after 120 hours of use (or approximately every 2 to 3 months based on the 3.
average of 1 to 2 hours of daily cooking time). Available at your local resellers.
Page 7
Page 10
Ductless Conversion
Ductless conversion is intended for applications where an exhaust duct work is not possible to be installed. •
When converted, the hood functions as a purifying hood rather than an exhaust hood. Fumes and exhaust
from cooking is drawn and ltered by a set of charcoal lters. The air is then puried and re-circulated back
within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct •
work, if possible. Only when the exhaust option is not possible should you recourse to converting the hood
into a purifying unit.
When converted to be a “purifying” unit, a set of charcoal lters and an air-diverter are required in addition to •
its standard aluminum lter set. Available at your local resellers. The standard aluminum lters are intended
to capture residue from cooking, the optional charcoal lters help to purify fumes exhausted from cooking,
and the optional air-diverter redirects ltered clean air back to the house.
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
(Please consult with a qualied electrician for 220-Volt 50 Hz voltage)
It is the customer’s responsibility:
To contact a qualied electrical installer.•
To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/•
NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22. 2 No.
0-M91 - latest edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician determine that
the ground path is adequate.
A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides
of the line.
DO NOT ground to a gas pipe.
Check with a qualied electrician if you are not sure that the range hood is properly grounded.
DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box through exible
armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain relief must be provided at each
end of the power supply cable.
Wire sizes (copper wire only) and connections must conform with the rating of the appliance as specied on
the model/serial rating label. Wire sizes must conform to the requirements of the National Electrical Code
ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian Electrical Code Part 1 and C22.
2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L. - or C.S.A. - listed conduit connector must be provided at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association ** CSA International
Batterymarch Park 8501 East Pleasant Valley Road
Quincy, Massachusetts 02269 Cleveland, Ohio 44131-5575
Page 8
Page 11
Preparation
Advanced Preparations:
Be familiar with the controls of the range hood by reading •
through Range Hood Operations, Page 13-14.
Place the range hood on a at, stable surface. Connect the •
range hood to a designated standard outlet and turn on the
range hood. Verify all operations of the range hood by referring to Range Hood Operations, Page 13-14.
Place all supplied parts and required hardware on a at, sta-•
ble surface and verify the existence of all supplied parts listed on Page 4.
Carefully remove the white plastic protective coat from the range hood, if any.•
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering the vent
opening.
Decide the location of the venting pipe from the hood to the outside. Refer to • Venting Methods on Page 7.
A straight, short vent run will allow the hood to perform more efciently.•
Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the •
hood.
IMPORTANT: Peel white plastic protective coat off the hood, if any.•
Use silver tape or duct tape to seal joints between pipe sections.•
For installing under the cabinet with recessed bottom, attach 4-inch wide wood ller strips (not provided) on •
each side. Refer to Figure 1.
Using references in • Installation on Page 10-12 and Measurements and Diagrams on Page 17-21, create ac-
cess opening for electrical wires and hood exhaust under the cabinet.
Require three or more person to move and
install this range hood. Spinal or other bodi-
ly injuries could occur if it is not followed.
WARNING
Excessive Weight
WARNING
Severe Injury
Rotating fan can cause severe
injury. Stay clear of fan when
motor is running.
CAUTION: If moving the cooking range is necessary to install the hood, turn OFF the power on an elec-
tric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE.
Puncture the knockout holes (for mounting under the cabinet) on the hood as shown in Figure 2.•
If necessary, attach two rubber stands with 3M adhesive tapes to the back corners of the hood.•
Figure 1Figure 2
Page 9
Page 12
Installation
Installations (refer to Page 4 for parts):
Measure the distance between stove top and the bottom of
range hood. A distance of 27” to 30” is recommended*.
*Due to different ceiling height congurations, recommend-
ed height may not be applicable.
You have 1. two ways (A: Vertical Venting, or B: Horizontal Venting) to mount this range hood:
Determine venting method as shown on Page 7 and proceed if you would like to vent vertically.1.
Using references in 2. Height & Clearance on Page 5-6, Measurements and Diagrams on Page 17-21,
Figure 3 and Figure 4 on next page, determine and clearly mark a centerline on the bottom of the cabi-
net.
Draw electrical wires through cabinet access opening on top of the range hood, center the hood beneath 3.
the cabinet and ush with the front of the cabinet.
From inside of the hood, place hood mounting screws into the exact center of each knockout hole and 4.
secure to cabinet bottom. Finish tightening all screws until secure. Be careful when using electrical
screwdriver, damage to the range hood may occur. Skip Part B below and proceed to Step 2.
CAUTION: Make certain the range hood is secure before releasing!
Determine venting method as shown on Page 7 and proceed if you would like to vent horizontally.1.
Using references in 2. Height & Clearance on Page 5-6, Measurements and Diagrams on Page 17-21,
Figure 5 and Figure 6 on next page, determine and clearly mark a centerline on the wall.
Punchure the knockout wire access hole and rear duct access hole on the back of the hood, draw electri-3.
cal wires through the wire access hole and attach rectangular vent adapter.
Draw electrical wires through the access opening on the wall behind the range hood (Figure 6), center 4.
the hood beneath the cabinet and ush with the front of the cabinet.
From inside of the hood, place hood mounting screws into the exact center of each knockout hole and 5.
secure to the wall. Finish tightening all screws until secure. Be careful when using electrical screw-
driver, damage to the range hood may occur.
CAUTION: Make certain the range hood is secure before releasing!
For safety purpose, pre-drilled mounting holes are provided through the back of the hood. For a more secure 2.
installation, use as many mounting holes as needed to secure from the inside of hood.
Use 6” round steel pipe (follow building codes in your area) to connect the exhaust on the hood to the duct-1.
work above. Use silver tape or duct tape to make all joints secure and air tight. Refer to Figure 6.
SAFETY WARNING: Risk of electrical shock. this range hood must be properly grounded. Make sure this
is done by qualied electrician in accordance with all applicable national and local electrical codes. Before
connecting wires, switch power off at service panel and lock service panel to prevent power from being
switched on accidentally.
Connect the range hood to a designated standard outlet or cut off the plug and connect three wires (black, 1.
white and green) to house wires and cap with wire connectors. Connect according to colors (i.e. black to
black, white to white, and green to green).
Store excess wires in the wiring box.2.
Turn Power ON using control panel (refer to 3. Range Hood Operations on Page 13-14). Check all lights and
fan operations.
Make sure to leave this Installation Guide for the homeowner.4.
Page 10
Page 13
Installation (Continued)
Hood Mounting Screws
Electrical Access Opening
Electrical Access Opening
Hood Mounting Screws
Wood Filler Strips
(Not included)
Figure 3: Cabinet Bottom View
UC200-4130W
Hood
Mounting
Screws
Electrical
Access
Opening
Wood Filler Strips
(Not included)
Wood Filler Strips
(Not included)
Hood
Mounting
Screws
Wall
Wall
UC200-1900 Class
Centerline
UC200-2000 Class
Centerline
Electrical
Access
Opening
Wall
Wood Filler Strips
(Not included)
Centerline
UC200-1800 Class
Centerline
Figure 4:
Electrical wires
through top opening
Wall
Page 11
Page 14
Installation (Continued)
Electrical WireOpening
Hood Mounting Screws
Electrical WireOpening
Hood Mounting Screws
Figure 5: Cabinet Front View
UC200-4130W
Centerline
UC200-1900 Class
Centerline
UC200-1800 Class
Centerline
Figure 6:
Electrical wires
through rear opening
Page 12
Page 15
Range Hood Operations
Control Panel Layout and Buttons Congurations:
1. Electronic Control
Filter Clean
Reminder
Light Control
Quiet
Speed
Low
Speed
High
Speed
Power Control
(On/Off)
This range hood is equipped with ve electronic controls, a powerful centrifugal squirrel cage motor with two
aluminum lters, two bright 20W~12V or 40W~120/240V halogen lights and a lter clean reminder.
The ve electronic buttons control the intensity of the Lights, Speeds (Quiet, Low and High) and Power (On/Off).
The Power Control (On/Off) offers startup, 3-minute delay or immediate power-off. The Light Control operates
independently from the Power Control (On/Off) and is not affected by the delay shutoff.
The aluminum lters are designed to deliver approximately 3 months of grease ltration between each cleaning.
The Filter Clean Reminder is set to turn ON after 100-hours of fan operation have elapsed since the installation
of cleaned or new lters. The timer for this reminder light will reset each time the lter is removed and the trigger
is released.
Filter Clean Reminder
Timer Reset Trigger
Turning Fan ON:
Always turn fans ON couple minutes before cooking to establish air ow and allow fans to run for a few minutes
after cooking for cleaner air in the kitchen. The Power Control (On/Off) button must be pressed before a Speed
Control button can be activated.
NOTE: The light setting will not be affected by the Power Control (On/Off) button.
With the range hood is OFF, press the Power Control (On/Off) button once. The LED on the Power Control •
button will be illuminated.
While the Power Control LED is illuminated, press one of the three speed control button (Quiet, Low and •
High) to activate the desired speed (the LED on the speed control button will turn on).
To change the fan speed, press another speed control button. The LED on the speed control button will be-•
come illuminated accordingly.
Page 13
Page 16
Range Hood Operations (Continued)
Control Panel Layout and Buttons Congurations:
Turning Fan OFF:
The 3-minute power-off delay function will only turn OFF fans. The light settings will not be affected by the delay
function.
Three-Minute Delay
While the fans are operating, press Power Control (On/Off) button once, the Power Control LED will ash •
and fans will turn OFF after 3-minutes.
During this 3-minutes delay, changing speeds will not affect the countdown.•
The 3-minute power-off delay function can be cancelled by pressing • press Power Control (On/Off) button
once while it is ashing.
Immediate Power-off
While the fans are in 3-minute power-off delay mode, press the illuminated• speed control button once to
turn OFF the fans immediately.
When the fans are operating in normal mode (Power Control LED not ashing), rapidly press the • Power
Control (On/Off) button twice to turn OFF the fans.
Light Control:
Light Control button operates independently from the Power Control (On/Off) and power-off delay function.
Pressing the Power Control (On/Off) button or activating the delay function will not turn halogen lights ON or
OFF. The lights have three settings: High, Low and OFF. CAUTION: DO NOT touch the lights until switched OFF
and cooled.
While the halogen lights are OFF, press the Light Control button once to turn halogen lights ON at High •
intensity. LED on Light Control will become illuminated.
Press the Light Control button again to change the light intensity to Low.•
Each touch of the Light Control button will cycle the light intensity through High, Low, and OFF.•
2. Three Speed Mechanical Control
Low Speed
Power Switch
Turn On:
Press the speed control (Low Speed, Medium Speed, High Speed) switch to select the desired level of power. •
Once button is pressed, the previous speed mode will cancel.
Press the Light Switch to power on the lights.•
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Turn Off:
Press the Power Switch to turn off the power.•
Press the Light Switch to power off the lights•
Medium Speed
High Speed
Light Switch
Page 14
Page 17
Troubleshooting
If the range hood or halogen light does not operate 1.
after installation:
The range hood vibrates when the blower is on:2. The range hood might not have been secured prop-•
The blower or fan seems weak:3. Check that the duct sized used is at least 6” or 3-1/4 •
The lights work but the blower is not spinning at all, 4.
is stuck or is rattling.
Check if the range hood has been plugged in, make •
sure that all power has been turned back ON, fused
not blown and all electrical wiring are properly con-
nected.
Swap out light assembly to working ones to deter-•
mine whether it is caused by defective bulbs. See
Replacing the light bulbs on Page 22.
erly on to the ceiling or wall.
x 10”. Range hood WILL NOT function efciently
with insufcient duct size. For example: 7” duct
over 6” hole and loosely secured.
Check if duct is clogged or if damper unit (half-cir-•
cular apper) is not installed correctly or opening
properly. A tight mesh on a side wall cap unit might
also cause restriction to the air ow.
The blower might be jammed or scraping the bot-•
tom due to shipping damage. Please contact us immediately.
The hood is not venting out properly:5. Make sure the distance between the stove top and •
NOTE: For all other inquiries, please contact us. Our contact information can be found on the back cover.
the bottom of the hood is within* 27” and 30” in
distance. *Due to different ceiling height congura-
tions, recommended height may not be applicable.
Reduce the number of elbows and length of duct •
work. Check if all joints are properly connected,
sealed, and taped.
Make sure the power is on high speed for heavy •
cooking.
Page 15
Page 18
Use and Care Information
Operations:
Read and understand all instructions and warnings in this manual before operating the appliance. Save these •
instructions for future reference.
Always leave safety grills and lters in place. Without these components, operating blowers could catch on to •
hair, ngers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.•
NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch re. The risk of •
self combustion is higher when the oil has been used several times.
NEVER cook on “open” ames under the range hood. Check deep-fryers during use: Superheated oil may be •
ammable.
Cleaning:
The saturation of greasy residue in the blower and lters may cause increased inammability. Keep unit clean •
and free of grease and residue build-up at all times to prevent possible res.
Filters must be cleaned periodically and free from accumulation of cooking residue (see • cleaning instructions
on Page 22). Old and worn lters must be replaced immediately.
DO NOT operate blowers when lters are removed. Never disassemble parts to clean without proper instruc-•
tions. Disassembly is recommended to be performed by qualied personnel only. Read and understand all
instructions and warnings in this manual before proceeding.
Specications
Specications3:
Body Design Stainless Steel or Seamless Steel, Powder Coating
Power Rating220V/50Hz or 120V/60Hz (USA & Canada standard)
Interference ProtectionRadio Frequency Interference Protected
1. In House Test Static Pressure “0”.
2. One sone is roughly equivalent to the sound of a refrigerator (1kHz) at 40 decibels.
3. Subject to change without notice, please contact your local reseller for details.
Page 16
Page 19
Measurements and Diagrams
All measurements in parenthesis are in millimeter.•
All inch measurements are converted from millimeters, thus inch measurements are estimated.•
UC200-4100 Class:
Front View
Rear View:
Top View:
Page 17
Page 20
All measurements in parenthesis are in millimeter.•
All inch measurements are converted from millimeters, thus inch measurements are estimated.•
UC200-2000 Class:
Front View
Rear View:
Top View:
Page 18
Page 21
All measurements in parenthesis are in millimeter.•
All inch measurements are converted from millimeters, thus inch measurements are estimated.•
UC200-1900 Class:
Front View
Rear View:
Top View:
Page 19
Page 22
All measurements in parenthesis are in millimeter.•
All inch measurements are converted from millimeters, thus inch measurements are estimated.•
UC200-1800 Class:
Front View
Rear View:
Top View:
Page 20
Page 23
Circuit Diagram:
GREEN
UC200-4100 Class
UC200-18/19/2000 Class
NOTE: Wiring Diagram shown above with GU10 light conguration. A transformer is required for MR16/J4 Lights.
Page 21
Page 24
Maintenance
SAFETYWARNING: Neverput your hand into area housing the
fan while the fan is operating!
For optimal operation, clean range hood & all lter/oil container regularly. Regular care will help preserve the range hood’s performance &
appearance.
Cleaning Exterior Surfaces:
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent (e.g. Comet •
Power Scruv®, EZ-Off® oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel
surface. For heavier soil use liquid degrease such as “Forumla 409®” or “Fantastic®” brand cleaner.
If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting •
cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. CAUTION: Do not
leave on too long as this may cause damage to hood nish. Use soft towel to wipe off the cleaning solution, gently
rub off any stubborn spots. Use dry soft towel to dry the hood.
After cleaning, you may use non abrasive stainless steel polish such as 3M•
luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
DO NOT allow deposits to accumulate or remain on the hood.•
DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.•
DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel •
for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after ex-
posure and wipe dry with a clean cloth.
Light bulb become extremely hot when turned on.
DO NOT touch bulb until switched off and cooled.
Touching hot bulbs could cause serious burns.
The aluminum lters tted by the factory are intended to lter out residue and grease from cooking. It need not be re-•
placed on a regular basis but are required to be kept clean. Filters should be cleaned after every 30 hours of use.
Remove and clean by hand or dishwasher. Spray “Formula 409•
if heavily soiled. Dry lters and re-install before using hood.
IMPORTANT: Drain oil from oil containers before oil and residue overow!
Replacing Filters:
Should lters wear out due to age and prolonged use, replace with following part number: SV168/198-ACS-AF/SF•
Note: Also replace damaged lter that has punctured or broken mesh, bent or broken frame.•
Replacing J4 Type Halogen Light Fixture:
When the range hood uses J4 type halogen light xture: 20W 12V (Product ID: SV-ACS-HAL20W).•
Make sure the range hood is unplugged or turn OFF breaker and the lights are cool to touch.•
Place a at-head screwdriver between light housing and hood body, gently pry up the light housing and search for the •
metal clip.
Apply force to the metal clip and pull out the light xture. Disconnect the power cable and discard the old light x-•
ture.
Reverse the steps to install a new halogen light xture. Turn ON breaker and range hood to test for operation.•
Light Housing
Flat-head Screwdriver
®
” or equivalent degreasing detergent and leave to soak
Hood
Body
Power Plug
Metal Clip
Page 22
Page 25
Maintenance (Continued)
Replacing J4 Type Halogen Light Bulb:
When the range hood uses J4 type halogen light bulb: 20W 12V.•
Make sure the range hood is unplugged or turn OFF breaker and the •
lights are cool to touch.
Place a small at-head screwdriver between light housing and lens cover, carefully and gently pry up the lens cover.•
Remove the old halogen light bulb by pulling in the direction of wavy arrow. Do not touch the new light bulb with •
bare hands.
Reverse the steps to install a new halogen light bulb. Turn ON breaker and range hood to test for operation.•
Light Housing
Flat-head
Screwdriver
Lens Cover
Replacing E12 Type light bulb:
When the range hood usesE12 type light bulb: 20W 12V or 40W 120/220V.•
(please contact your local reseller for replacement)
Make sure the range hood is unplugged or turn OFF breaker.•
Place a at-head screwdriver between light cover and hood casing, gently pry to remove light cover.1.
Gently unscrew defective bulb straight out and discard.2.
Wear a cotton glove or use a cloth to handle the replacement bulb (DO NOT handle with bare ngers as this may 3.
shorten the life of the bulb). Tighten gently but securely into light socket. NOTE: DO NOT tighten too hard as bulb
may break off.
Replace light cover.4.
Turn ON breaker and range hood to test for operation.•
Light
Cover
Halogen Bulb
Lens Cover
WARNING
Hazard of Burns!
Light bulb become extremely hot when turned on.
DO NOT touch bulb until switched off and cooled.
Touching hot bulbs could cause serious burns.
Lens Cover
Light
Cover
Hood
Casing
Flat-head Screwdriver
Replacing MR16 / GU10 Type Halogen Light Bulb:
When the range hood uses MR16 or GU10 type halogen bulb (please refer to •
the actual specication of the hood purchased):
USA/Canada:
35W Type MR16 12V / Type GU10 120V
Europe and other Countries:
35W Type MR16 12V / Type GU10 220V
Make sure the range hood is unplugged or turn OFF breaker. •
Make sure the lights are cool to touch, carefully align the arrow on the inner •
ring with the arrow on the outer ring where it says OPEN. The inner ring will
loosen and the light bulb will be available for removal. Install a new halogen
light bulb and reverse the steps.
Turn ON breaker and range hood to test for operation.•
Light
Bulb
Align arrows on both rings
Page 23
Page 26
Warranty
TO OBTAIN SERVICE UNDER WARRANTY:
You must present proof of original purchase date.
Please provide an original dated proof of purchase (sales receipt / invoice) in order to obtain service under warranty.
One Year Parts Warranty:
For one year from the date of original purchase, your local reseller will provide free of charge, non-consumable replacement parts or components that failed due to manufacturing defects. Subject to the conditions and limitations set forth
below, your local reseller will, at its option, either repair or replace any part of its products that prove defective by reason
of improper workmanship or materials. Repaired parts or replacement products will be provided by your local reseller
on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. The consumer is responsible for all shipping costs. Consumable parts not covered by this warranty include but not limited to: Light bulbs,
metal, aluminum and charcoal lters.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary home use.
This Warranty Will Be Voided When:
Product damaged through negligence, improper installation, accident, abuse, misuse, natural disaster, insufcient or
excessive electrical supply, abnormal mechanical or environmental conditions, or any unauthorized disassembly, repair,
modication, or failure to follow installation instructions. When product is used commercially or other than its intended
purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modied by
anyone other than your local reseller’s authorized agents. This limited warranty also does not apply to any product on
which the original identication information has been altered, obliterated or removed, has not been handled or packaged
correctly or has been sold as second-hand.
What is Not Covered:
Consumable parts such as light bulbs, metal and charcoal lters. The natural wear of nish, and wear due to improper
maintenance, use of corrosive and abrasive cleaning products, pads, and oven cleaner products. Chips, dents or cracks
due to abuse, misuse, freight damage, or improper installation. Damage of product caused by accident, re, oods or
act of God. The manufacturer and/or distributor/reseller is not liable for, and does not cover under warranty, any loss of
properties or any costs associated with removing, servicing, installing, or determining the source of problems with this
product.
This warranty is valid in the country of the original purchase at retail. It is non-transferable and applies only to the original
purchaser and does not extend to subsequent owners of this product. Any applicable implied warranties, including the warranty of merchantability, are limited in duration to a period of express warranty as provided herein beginning with the date
of original purchase at retail and, no warranties, whether express or implied, shall apply to this product thereafter.
To obtain warranty service, you may contact your local reseller from which you purchased this product. Please conrm the
terms of your local reseller’s policies prior to contacting. Typically, you must include product identication information,
including model number and serial number with a detailed description of the problem you are experiencing. You must also
include proof of the date of original retail purchase as evidence that the product is within the applicable warranty period.
The information in this document is subject to change without notice, please contact your local reseller for updated details.
Page 24
Page 27
Disclaimer
Carefully inspect all items for damages before accepting delivery. note any damages on the freight bill or
express receipt. request name and signature of the carrier’s agent and keep copy to support your claim. Upon
acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the carrier and le
a claim immediately. Failure to do so may result in the denial of your claim. The carrier will furnish you with
necessary forms for ling a claim.
Damages caused during transit are not covered under our warranty. Please contact us to le an insurance claim.
Please inspect contents of package(s) carefully upon receiving! We must be notied of any damages and/or
missing parts within ve (5) days upon your receipt of package(s). Claims will not be accepted after ve (5)
days. NOTE: Items were thoroughly tested and carefully packed in our factory before shipping.
Products must be returned in good working condition with ALL original parts and documentation packed in
ALL original cartons, llers and shipping cartons. A restocking fee of 15% will be charged for all approved
return(s). Exchanges or returns may not be accepted if any packaging is missing.
Make sure to inspect the hood for damages and defects before installation. Appearance aws of the hood found
after installation and not affecting hood performance is not covered under our warranty for returns or exchanges. Service visits not covered under warranty will carry a service charge.
Before Installation: Return for exchange or refund (please see above for acceptable returns).
After Installation: NO exchange or refund.
Contact Us
If you need any assistance, please contact your local reseller. Please have your order number and model of the
range hood ready. This information will help them better respond to your request.
If you need replacement parts, we recommend that you only use genuine parts. Our accessories and parts are
engineered and designed specically for this series of range hood, each is rigorously tested assuring the utmost
in durability and reliability, providing a factory match, factory-installed appearance and functionality tailored to
each individual range hood model.
The information in this document is subject to change without notice, please contact your local reseller for updated details.
Page 25
Page 28
SPAGNA VETRO
Spagna Vetro Appliances Inc
Burnaby ,BC , Canadawww.KitchenHoods.ca
tel. 604 430 5252
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.