Spagna Vetro PSM Installation Manual And User's Manual

Installation Guide
and Users Manual
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer: Leave this guide with the homeowner Homeowner: Keep this guide for future reference
Wall Mount Range Hood
Model: PSM
Rev. 3046u.2a
Important Safety Notice
Read all Instructions before Installing and operating this appliance
The installation in this manual is intended for qualied installers, service technicians or persons with similar qualied background. Installation and electrical wiring must be done by qualied profession­als and in accordance with all applicable codes and standards, including re-rated construction.
DO NOT attempt to install this appliance yourself. Injury could result from installing the unit due to lack of appropriate electrical and technical background.
Range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any parts for installing, cleaning or servicing.
Activating any switch ON before completing installation may cause ignition or an explosion.
Due to the size and weight of this range hood, two people installation is recommended.
To reduce the risk of re, electric shock, or injury to persons:
For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and va- pors.
The combustion air ow needed for safe operation of fuel-burning equipment may be affected by this
unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
Before servicing or cleaning unit, switch power OFF at service panel and lock service panel to pre­vent power from being switched ON accidentally.
Clean grease laden surfaces frequently. To reduce the risk of re and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl spaces, ceiling, attics or garages.
Ducted fans MUST always be vented to the outdoors.
Use only metal ductwork and this unit MUST be grounded.
Sufcient air is needed for proper combustion and exhausting of gases through the duct to prevent
back drafting.
When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hid­den utilities.
All electrical wiring must be properly installed, insulated and grounded.
Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease re.
Check all joints on duct work to insure proper connection and all joints should be properly taped.
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the vendor.
To reduce the risk of a stove top grease re:
Keep all fan, bafe, spaces, lter, grease tunnel, oil container and grease-laden surfaces clean. Grease should not be allowed to accumulate on fan, bafe, spaces, lter, grease tunnel and oil container.
Always turn range hood ON when cooking at high heat or when cooking aming foods.
Use high settings on cooking range only when necessary.
Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers
that may ignite. Heat oils slowly on low or medium settings.
Page 1
Important Safety Notice
Table of Contents
Read all Instructions before Installing and operating this appliance
Clean ventilating fan frequently.
Always use appropriate cookware and utensils size.
Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury to persons in the event of a stove top grease re:
SMOTHER FLAMES with a close-tting lid, cookie sheet, or metal tray, then turn OFF the burner. BECAREFUL TO PREVENT BURNS. NEVER PICK UP A FLAMING PAN—you may be burned. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the ames DO NOT go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately.
DO NOT USE WATER, including wet dishcloths or towels — a violent steam explosion will result.
Use an extinguisher ONLY if:
You know you have a Class A, B, C extinguisher, and you already know how to operate it.
The re is small and contained in the area where it is started.
The re department is being called.
You can ght the re with your back to an exit.
INSTALLATION
Tools needed....................................................3
Parts supplied...................................................4
Venting requirements.......................................5
Mount heights & clearance...........................5-6
Calculating vent system length.......................6
Venting methods & ductless conversion..........7
Charcoal lters & electrical requirements.......8
Preparation......................................................9
Installation................................................10-11
Range hood operations............................12-13
Wiring diagram & measurements...........14-16
Tools needed:
USE AND CARE
Troubleshooting...........................................17
Use and care information...............................18
Specications..............................................18
MAINTENANCE
Cleaning...............................................19
Replacing lter & light bulb.........................19
WARRANTY
Coverage & exceptions.................................20
Disclaimer & contact information..................21
To reduce the risk of injury to persons in the event of a gas leaks:
Extinguish any open ame.
DO NOT turn on the range hood fan or any type of ventilator.
DO NOT turn on the lights or any type of appliance.
Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and re
department, or dial your local emergency service immediately.
Your safety and the safety of others is very important. We have provided many important safety mes­sages in this manual and on your appliance. Always read and obey all safety messages. All safety mes­sages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
WARNING
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others. All safety messages will follow the safety alert symbol and the word “WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure to ob­serve the instructions given here for installation, maintenance and suitable use of the product. The manufacturer and/or distributor/reseller further declines all responsibility for injury due to neg­ligence and the warranty of the unit automatically expires due to improper maintenance. The manufacturer and/or distributor/reseller will not be held responsible for any damages to per­sonal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
Page 2
Marker or
pencil
Level
Utility knife
Powered
screwdriver or drill
Measuring tape
Flat-blade and Phillips screw-
drivers
Page 3
Parts supplied:
Professional Range Hood : Model PSM
Venting Requirements Height & Clearance
Lower standard chimney
Upper standard chimney
Stainless Steel Bafe Filter(s)
Grease Tunnel
Chimney Mounting Bracket
Page 4
Vent system must terminate to the outside (roof or side wall).
DO NOT terminate the vent system in an at­tic or other enclosed area.
DO NOT use 4” (10.2 cm) laundry-type wall caps.
Use metal/aluminum vent only. Rigid metal/ aluminum vent is recommended.
DO NOT use plastic vent.
Always keep the duct clean to ensure proper
airow.
Calculate the following gures before instal­lation:
1. Distance from the oor to the ceiling.
2. Distance between the oor to the coun-
tertop/stove (recommend* 28” to 36”).
3. Distance between the countertop/stove
to the range hood.
4. Height of hood and duct cover.
For the most efcient & quiet operation:
A distance of 28” to 36” is recommended* between stove top and the bottom of range
hood.
It is recommended that the range hood be
vented vertically through the roof through 8” or bigger round metal/aluminum vent work.
The size of the vent should be uniform.
Use no more than three 90° elbows.
Make sure there is a minimum of 24” (61
cm) of straight vent between the elbows if more than one elbow is used.
DO NOT install two elbows together.
The length of vent system and number of
elbows should be kept to a minimum to pro­vide efcient performance.
The vent system must have a damper. If roof or wall cap has a damper, DO NOT use damper (if supplied) on top of the range
hood.
Use silver tape or duct tape to seal all joints
in the vent system.
Use caulking to seal exterior wall or roof opening around the cap.
* Due to different ceiling height congurations, rec-
ommended height may not be applicable.
Maximum* ceil-
ing clearance
110” at 31” hood
mounting height
above countertop/ stove (may vary
with different
model). Chimney extensions avail­able for higher
ceiling.
Max*: 110”
Mounting
Bracket Standard
Upper
Chimney
Extension available*
Standard
Lower
Chimney
Extension available*
Range hood
Min: 28” Max: 36”
Countertop/Stove
36” base
* Higher ceiling requires chim-
ney extension. Available at your
local resellers.
Page 5