SpaEquip BE1660QBTF Installation Instruction

Installation Guide
Product Code: BE1660QBTF
www.spaequip.com
P:707.737.1100 F:707.737.1150
Page 1 of 5
PRODUCT #:
BE1660QBTF
FEATURES:
Shampoo Bulkhead Upper and lower units. Consists of 1660UTF and 1660LTF. Wall mounted cabinets. Unfinished on right sides, order 1664QATF end panels to finish. Upper cabinet with sliding doors. Lower cabinet. Predrilled holes for
Belvedere bowl. Order bowl separately. Bottle well 18" w x 6 3/4 d x 6 h. Accent strip may be specified as trim. Oversized item - ships by Truck
ITEM:
Shampoo Bulkhead Upper and Lower Units
BRAND:
Belvedere
SpaEquip, Inc. 211 Wappo Ave., Calistoga, CA 94515
p: 707.737.1100 f: 707.737.1150
www.spaequip.com
LIST PRICE (USD):
SPECIFICATIONS:
Dimensions: 45" W x 12" D x 78" H Electrical: None
Suggested Outlet: None Plumbing: See specs for shampoo bowl
Notes: None Warranty: 1 Year
Certifications: N/A Country of Origin: United States
Installed By: Client's Contractor
www.spaequip.com p: 707.737.1100 Page 1 of 5
Shampoo
Product Code: BE1660QBTF
www.spaequip.com
P:707.737.1100 F:707.737.1150
Page 2 of 5
Bulkheads
BULKHEAD INSTALLATION AND PLUMBING INSTRUCTIONS
CAUTION: Cabinetry is heavy. Use care in
lifting, moving and handling.
IMPORTANT NOTES: A. It is the responsibility of the owner and/or the
installers to confirm that the installation meets local codes regarding plumbing, materials, venting, etc.
B. Read through these instructions carefully before
beginning work. Because we cannot anticipate all t ypes of wall and floor constructions, you must obtain some fasteners for the installation locally.
1. Determine the final location for the bulkhead. For corner installations where the left end is against the wall, allow at least 14 inches from the baseboard to the center line of the bowl, to provide for the shampoo chair base.
BELVEDERE BULKHEADS: COSMOS,
LTD., MODULAR, SAVANNAH
COSMOS
MODULAR
LTD.
SAVANNAH
)RU URXJK LQ SOXPELQJ VHH LOOXVWUDWLRQ y$y
Check with local plumbing codes for approval.
C
ILLUSTRATION
y$y
WARNING: Once the shipping cleats have been removed from the lower cabinet, it is unstable and must be supported. Damage to the cabinet or personal injury may result if the cabinet falls.
2. To remove the skid and shipping cleats from the lower cabinets, remove the screws attaching the cleats to the inside of the end panels.
3. Locate and cut holes for the plumbing waste
Drain
y
Floor
L
Hot
Cold
y
y
y
and supply stubs in the front panel of the lower cabinet. Measure carefully. Use a hole saw or jig saw. Apply tape to the laminate face to avoid scratching. Care taken at this step will ensure a neat, professional installation.
4. Secure 2 x 4 studs (cleats), one to the floor and one to the wall with suitable fasteners. Position the lower cabinet over plumbing stubs and cleats. Secure the lower cabinet to both the floor and wall. Use fasteners (obtain locally) suitable for your wall and floor construction.
WARNING:
of the bowl and load if it is not permanently to both the wall and the floor. Personal injury could result if the cabinet pulls away from the wall.
5. If bulkhead units are ganged together, both the upper and lower end panels of adjoining units must be secured together with suitable fasteners. The bulkhead is now ready for bowl installation and final plumbing.
The cabinet may not support the weight
secured
www.spaequip.com p: 707.737.1100 Page 2 of 5
Page 1 of 4
Belvedere USA Corporation
A Wholly Owned Subsidiary of Wella Corporation
One Belvedere Boulevard, Belvidere, Illinois 61008
Printed in U.S.A. 4000749 Rev. 1-01
BULKHEAD PLUMBING LAYOUTS
Product Code: BE1660QBTF
www.spaequip.com
P:707.737.1100 F:707.737.1150
Page 3 of 5
1660QB COSMOS
453/
4
137/
16
319/
16
SL61-42QC LTD. SL61-48QB LTD.
123/
42
4
291/
4
153/
4
48
321/
4
%RZO FHQWHUOLQH y
to Bowl centerline of adjacent Bulkheads
www.spaequip.com p: 707.737.1100 Page 3 of 5
%RZO FHQWHUOLQH y
to Bowl centerline of adjacent Bulkheads
Page 2 of 4
%RZO FHQWHUOLQH y
to Bowl centerline of adjacent Bulkheads
0460-40QC MODULAR SV60-42QC SAVANNAH SV60-48QC SAVANNAH
Product Code: BE1660QBTF
www.spaequip.com
P:707.737.1100 F:707.737.1150
Page 4 of 5
123/4
40
27
42
1
/
4
123/
4
291/
4
153/
4
48
321/
4
%RZO FHQWHUOLQH y
to Bowl centerline of adjacent Bulkheads
www.spaequip.com p: 707.737.1100 Page 4 of 5
%RZO FHQWHUOLQH y
to Bowl centerline of adjacent Bulkheads
Page 3 of 4
%RZO FHQWHUOLQH y
to Bowl centerline of adjacent Bulkheads
CABINET INSTALLATION INSTRUCTIONS
Product Code: BE1660QBTF
www.spaequip.com
P:707.737.1100 F:707.737.1150
Page 5 of 5
! CAUTION !
Damage or personal injury may result if you do not use proper fasteners for your wall construction.
To determine the type of fastener to purchase when installing cabinets or mirror clips, use the following information.
Because wall constructions vary, Belvedere USA Corporation does not provide wall anchors for installation.
Be sure that you select suitable fasteners appropriate to your particular wall construction. If your wall construction is different from the following types, cons ult a contractor for recommended suitable fasteners.
CONCRETE WALL:
Recommend using expansion anchors. Size to be determined by interior wall structure and weight of unit.
GYPSUM WALL:
Recommend using expansion anchors or toggle bolts. Size to be determined by interior wall structure and weight of unit.
Gypsum does not have sufficient strength to support a cabinet. Cabinets must be secured to the interior wall structure.
WOOD WALL OR CABINET:
Recommend using wood screws. Size to be determined by interior wall structure or cabinet panel and weight of unit.
www.spaequip.com p: 707.737.1100 Page 5 of 5