Spa Electrics LV50-12 Installation Manual

INSTALLATION GUIDE
FOR ASSISTANCE PLEASE CONTACT SPA ELECTRICS
ph: +61 3 9793 2299 info@spaelectrics.com.au www.spaelectrics.com.au
INSTALLATION
93mm
500mm (MIN)
GROUND
LV50-12
LOW VOLTAGE TRANSFORMER
Mount unit using the 2 keyhole slots provided, at 93mm centres.
CABLE TERMINATION
Spa Electrics recommends the use of an Electrical Contractor or Pool Technician for connection of the Pool Light to the Transformer.
1. Remove the terminal screw and clamp plate from the terminal bolt.
The LV50-12 transformer has 2 outputs, each with a pair of terminals. Each cable core should be terminated as follows:
For the second cable core, repeat these steps on the adjacent terminal.
Optional: Once the cable termination is complete, anchor the cable to the transformer using the cable management hooks provided. This will help protect the cable from strain.
2. Place one of the stripped end of the cable on top of the terminal bolt. Place the clamp plate on top of the cable end and fasten the connection in place. As the Transformer outputs AC power the cable orientation is not important
Ensure that the unit is installed at least
3.5 metres away from the pool and/or spa and at a minimum of 500mm above ground level.
INSTALLATION GUIDE
TRANSFORMER RATING
Input: 230-240VAC ~ 50Hz Output: 2 X 25W 12VAC ~ 50Hz switched Fuse: 2 x 3A 12VAC Blade Fuse Auxilary GPO: 230-240VAC ~ 50hz 10amp Max Total IP Rating: IP23
TECHNICAL SPECIFICATION
FOR ASSISTANCE PLEASE CONTACT SPA ELECTRICS
ph: +61 3 9793 2299 info@spaelectrics.com.au
www.spaelectrics.com.au
20180226
LV50-12
LOW VOLTAGE TRANSFORMER
CHECKING THE FUSE
The LV50-12 transformer includes 2 x 3amp blade fuses, one for each output. The fuse is designed to protect the transformer and light cable from shorts & over loading, which may lead to the premature replacement of the transformer.
The following steps show how to check if your transformer fuse has blown:
1. Remove the fuse cover.
2. Remove the fuse, the fuse may be held firmly in the fuse holder, if so it may be necessary to use a pair of needle nose pliers to gently remove the fuse.
3. Check the center of the fuse for breaks. If the fuse has blown, first check all cable connections for shorts before replacing the fuse.
Note: Spa Electrics uses generic blade fuses, which can be purchased from any quality auto parts/Electrical retailer.
CONDITION PROBABLE CAUSE REMEDY
GOOD BAD
No Output Power No Input Power Check input power GPO using another appliance.
If power is available at GPO, contact Spa Electrics for further assistance
Blown Fuse Check fuse,
If the fuse has blown, first check all cable connections for shorts before replacing the fuse.
If fuse wire is intact, contact Spa Electrics for further assistance.
TROUBLE SHOOTING