SpaceLas PT-40K User Manual

Scanner Set
USER MANUAL
please read this manual carefully before your install the scanners!
Thank you very much for choosing our product ,if you have any question,please
send email to me.
MODEL:PT-40K
Checking Parts Please make sure the following parts are included:
2 Scanners 2 Driver board 2 Replacement mirrors 1 Scanne mount 1 power supply(PUS) 2 Cables driver to scanner 2 Cables driver to PUS 1 User manual
Introduction
The 40K is a fast and versatile galvo scan system, based on moving magnet galvanometers,
with a small and rugged dual channel closed loop diver . The system runs at pretty low voltage, and can be implemented in almost any existing or new application. With it's driving speed of up to 60k with the ILDA test pattern, displayed at an angle of 4-5 .
The standard delivery package contains driver , power supply and input cable .The driver is presetted to the included galvos, but has to be retuned slightly before first use. This can be done by using the three adjustment trimmers on the driecard. Please note, that the galvos are not set for maximum speed at small scan angle, but set to a usable angle of 20 at 38Kpps.
The cable
High speed galvanometers demand for special cables, which are shielded an separated between
motor and position detector. Cable lengths up to 100cm are allowed. We recommend a cable length of maximum 50cm.
Power source
Power source is not very critical and has minor influence on speed and quality of the complete
scanner system .Even if a standard transformer with a bridge and caps will do, We recommends a stabilized or switched power supply. The driver board is able to run between +/­ 24VDC to +/-28VDC, at 1A each. Recommended power supply is the PSU with 2x24VDC.
If you use transformer and bridge, then make sure to have minimum 10,000 uF caps per voltage, better 40,000 uF, parallel with a 100uF for fast peaks. Do not use extra capacitors at switching power supplies.
Polaritiy of connecting power to the driver is important. No warranty if connected incorrect.
The measuring procedure
The 40K was measured with Mamba Black with USB-Box, running at the desired output speed, using the standard ILDA test pattern. Laboratory power supply at +/-24VDC, room temperature. Windows PC with Mamba Black , 12/30k ILDA testframe. It was also tested afterwards with pangolin LD2000, running the same test pattern. 5x10x0.7mm mirror was used during measuring period. Tests showed a slight decrease of performance at about 5 by using a larger 6x11x0.7mm mirror. The galvos where fixed in the standard mounts on an aluminum baseplate, no forced cooling.