S&P HDT Series, HDB Series Instructions For Use And Installation

Serie HDT / HDB Ventiladores Helicoidales Axial Fans Ventilateurs Helicoïdes Axial-Ventilatoren Ventilatori elicoidali Exaustores elicoidais Axiaal ventilatoren
Instrucciones de uso e instalación. / Instructions for use and installation. Instructions d'emploi et d'installation. / Einbau- und Bedienungshinweise. Instruzioni per l'uso et il montaggio. / Instruções de uso e instalação. Installatie- en gebruiksvoorschriften.
ENGLISH HDT/HDB INSTALLATION INSTRUCTIONS
The HDT/HDB range of Plate Axial Fans have been manufactured to the rigorous standards of production and quality laid down by the International quality standards ISO9001.
The HDT/HDB range have been specifically designed and developed for use in potentially explosive atmospheres including Group II – Category 2G gases, Zone 1. The range are all marked with the CE label and conform with the ATEX 94-9-CE directive.
They are marked as products: II 2G The motors fitted on those fans, either for flameproof application or increased safety
application, are certified by a notified laboratory and comply with the requirements of the 94/9/CE ATEX Directive
Installation Instructions
It is recommended to check the following points when receiving this product: That it is the correct size.
That it is the correct model type (Single-phase or three-phase motor). That the data on the rating label are those required (voltage, frequency etc). The compatibility between the data on the rating label with the explosion proof stan­dards, exhaust atmosphere, zone of use, ambient temperature and the temperature listed (T1 to T6).
The installation and electrical connection work should be carried out in accordance with all applicable national and local building code regulations pertaining to explosive atmospheres and installations. All installation and electrical connection work must be carried out by suitably qualified persons.
In case of using an increased safety motor, the installation must include a suitable electrical protection device that disconnects the product from the electrical supply in the case where the impeller is prevented from turning and temperatures beyond those indicated on the rating label could be encountered.
All products must be installed in the fixing holes provided using suitably appropriate screws or bolts accordingly. All products must be wired to the mains electrical sup­ply in accordance with the enclosed electrical instructions. Before connecting the electrical supply to the fan it is important to ensure that there are no obstructions to the rotation of the impeller.
If the products are intended to be installed in an explosive atmosphere (*) that is accessible to users then suitable guards/protection devices must be included in order to comply with machinery directive 89/392/CE. For suitable guards/accessories please consult the S&P General Catalogue or your nearest distributor accordingly.