Soyal AR-331, AR-331H, AR-321, AR-721H, AR-725 User Manual

...
®
SOYAL
ACCESS CONTROL SYSTEM
Contents
AR-321 (H): Touch-panel Metal Housing
1
Product
2
User Guide
AR-721(H) / AR-725 (H) / AR-757 (H)
AR-321 (H) / AR-331 (H) /
3
Terminal Cables
4
Tools
5
Water proof Strip
V140707
P1
P2
P3
P4
AR-331 (H): Touch-panel Metal Housing / AR-331 (H-S): Metal Housing
1
Product
or
WG keyboard
AR-331 (H) AR-331 (H-S)
[Optional]
2
Optional
AR-721RB Digital Relay
or
AR-821RB Original Relay
3
User Guide
AR-721 (H)
1
Product
2
User Guide
3
Terminal Cables
P1
AR-725 (H): Illuminated Touch-panel
AR-725 (H-M)
1
Products
A.
B.
C.
D.
2
User Guide
AR-725 (H)
1
Products
2
User Guide
d x2
Additional external relay must be purchased.
4
Terminal Cables
P7
P2
P3
P4
3
Terminal Cables
P1
P3
3
Terminal Cables
5
Tools
c x2
g x1 h x1
4
Tools
4
Tools
P2
P4
4
c x2
e x1
Tools
A1.
E.
AR-725 (X)
1
Products
A2. A3.
AR-757 (H)
1
Product
Parts Description
a.
Button Head Pozidriv Tapping Screw: M3x10
e. f.
Security Torx Screw: M3.5x15
P1
F.
B.
C. H.G. D.
2
User Guide
b. c. d.
Button Head Pozidriv Slotting Screw: 2.5x10
Flat Head Hex Socket Screw: M3x8
3
Terminal Cables
P1
Flat Head Cap Philips Tapping Screw: 4x19.1
g. h.
Security Torx Screw: M3x10 Security Torx Wrenches
P2
P3
P3
P4
P2
P4
2
Tools
a x2
b x2
c x2
4
Tools
P6
Flat Head Cap Philips Tapping Screw: 4x38
e x1
Installation
AR-321 (H)
3
2
4
AR-331 (H) / AR-331 (H-S)
2
1
AR-721 (H)
4
Access Controller
Touch-panel Metal Housing / Illuminated Touch-panel
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the mounting plate onto the wall.
Attach the water proof strip to the body, then connect the terminal cables to the body and attach the body to the mounting plate.
1
4
3
Use the Allen key and screws (accessories supplied) to assemble the body onto the mounting plate.
Turn on the power, and LED will light and beep will sound.
Remove the rubber plug. To cut tamper-resistant column and make it fit the appropriate
height for actual installation. First, take off the metal casing then screw the controller on the wall. Second, put the metal casing back and lock it with security screw. Finally, put the rubber plug into the hole.
5
Pull the cables from the square hole of the mounting plate.
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
Connect the terminal cables to the body and attach the body to the mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Turn on the power and LED will light and beep will sound.
6
Turn on the power, and LED will light and beep will sound.
V140707
AR-725 (H)
AR-725 (H-M)
2
C.
1
c.
AR-725 (H)
1
AR-725 (X)
A1.
1
G.
Pull the cables from the square access hole of the mounting plate C.
Use a screwdriver to screw the metal plate C onto the wall.
3
A.
A.
4
B.
B.
5
A.
C.
B.
A.
6
8
D.
7
Take off the plastic mounting plate B from the body A, and pull the cables through the access hole of C and B, then connect to the body A.
C.
Assemble plate B with the body A, and embed the water proof strip D
d.
onto the plastic side frame.
Assemble the body A onto the mounting plate C with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
E.
F.
A1.
3
F.
2
Use a screwdriver to screw the base F onto the wall.
Attach the water proof gasket to the body A1, and pull the cables from the square hole of the base F, and connect to the body A1.
Assemble the body A1 with the base F.
4
e.
5
Screw A1 and F tight with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Put on G, and attach A1 onto the plastic plate A3, and screw it with the Allen key and screws (accessories supplied).
Put the ring O on the metal frame, and put them together onto the reader A1+A3, and screw them and buckle up the 4 buckles on the back.
Embed the water proof strip D onto the frame side of the base.
Following by the install process of AR-725 (H-M)
A3.
A2.
H.
A1.+A3.
2
b.
e.
3
D.
4
a.
5
AR-757 (H)
5
4
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Embed the water proof strip 3 onto the frame side of the base.
Connect the terminal cables to the body and attach the body to the mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
SOYAL
ACCESS CONTROL SYSTEM
Notice
1.Tubing:
2.Wire selection:
3.Power supply:
Connector Table
AR- 321H
AR-321 (H)
125kHz
13.56MHz
AR-331 (H) / AR-331 (H-S)
125kHz
13.56MHz
The communication wires and power line should NOT be bound in the same conduit or tubing.
Use AWG 22-24 Shielded Twist Pair to avoid star wiring.
Don’t equip controller and lock with the same power supply. The power for controller may be unstable when the lock is activating, that may make the controller malfunction.
The standard installation: Door relay and lock use the same power supply, and controller use independent power supply.
P4
P3
P7
10 98765432
P5
P1
®
P2
AR-321 (H) / AR-331 (H) /
AR-721(H) / AR-725 (H) / AR-757 (H)
P1Cable :
Wire Application
Lock Relay
Common-COM-Point Door contact Exit Switch Alarm Relay Power
P2Cable :
Wire Application
Wiegand
Beeper
LED
Pin
Blue White
1
Purple White
2 3 4 5 6
Thick Red
7
Thick Black
8
Pin
1
Thin Blue
2
Thin Green 3 4 5
Color
White
Orange
Purple
Gray
Color
Pink Brown Yellow
Description
(N.O.) DC24V1Amp (N.C.) DC24V1Amp (COM) DC24V1Amp Negative Trigger Input Negative Trigger Input Low output; Max 12V/100mA (Open Collector) DC Power 12V DC Power 0V
Description
Wiegand DAT:1 Input Wiegand DAT:0 Input Beeper Output 5V/100mA, Low LED Green Output 5V/20mA, Max LED Red Output 5V/20mA, Max
V140707
AR-721 (H)
125kHz
P3
P2
P4
P1
P5
13.56MHz
P4
AR-725 (H)
125kHz
P3
P2
P1
P4
13.56MHz
P5
AR-757 (H)
125kHz 13.56MHz
P3
P6
P1
P2
P4
Connectors Comparison
AR-321 (H) AR-331 (H) AR-721 (H) AR-725 (H) AR-757 (H)
P1 P2 P3 P4 ( P7 P8 P1 P2 P3 P4 ( P1 P2 P3 P4 ( P1 P2 P3 P4 P6
P3Cable :
Wire Application
Networking Module
P4Cable :
P2
P1
P3
P5
Wire Application
Tamper Switch
P5Cable :
Wire Application
P5
P2
P1
P4
P3
P3
P6
P1
P2
P4
Optional
Optional
Optional
)P5
)P5 )P5
3-PIN Connector
P6Cable :
Wire Application
Doorbell Arming Duress LED indicator
P7Cable :
Wire Application
Power
Exit Switch Networking Module
Lock Relay
Networking Module
Tamper Switch
Alarm Relay Door contact
LED
Beeper
Wiegand
Pin
Color
1
Thick Green
2
Thick Blue
(Contact Rating: 1A 125VAC/24VDC)
Pin
Color
1
Red
2
Orange
3
Yellow
(Optional)
Pin
Color
1
Black
2
White
3
Purple
Pin
Color
1
Brown White
2
Red White
3
Yellow White
4
Green White
(Directly connected at the Access controller)
Color
Pin
Thick Black
1
Thick Red
2
Purple
3
Thick Green
4
5
White
Thick Blue
6
Yellow White
7
Orange White
8
Gray
9
Orange
10
Brown
11
Yellow
12 13 14 15
Pink
Thin Blue
Thin Green
Description
RS-485(B-) RS-485(A+)
Description
N.C. COM N.O.
Description
GND. Duress Arming/ Security trigger signal
Description
BE Output AR Output/ Security trigger signal Output DU Output/ TTL out Hi input/ Green light brighten
Description
DC Power 0V DC Power 12V Negative Trigger Input RS-485(B-) Low output; Max 12V/100mA (Open Collector)/ Security trigger signal Output RS-485(A+) N.O. COM Low output; Max 12V/100mA (Open Collector) Negative Trigger Input LED Green Negative Output 5V/20mA, Max LED Red Negative Output 5V/20mA, Max Beeper Negative Output 5V/100mA, Low Wiegand DAT:1 Input Wiegand DAT:0 Input
After S/N: 0706-XXXXXX
Loading...
+ 5 hidden pages