Southbend Range DMT-40 Installation Manual

southbend
A MIDDLEBY COMPANY
OWNER'S MANUAL
INSTALLATION USER'S GUIDE
DIRECT STEAM POWER TILTING OR STATIONARY KETTLE
MODELS: DMT-30, DMT-40, DMT-60
These instructions should be read thoroughly before attempting installation. Set up, installation and Performance Check should be performed by a qualified service technician. The Manufacturer. Southbend (1100 Old Honeycutt Rd.. Fuquay-Varina, North Carolina
27526), informs you that unless the installation instructions for the above described Southbend product are followed and performed by a qualified service technician, (a person experienced in and knowledgeable concerning the installation of commercial gas and/or electrical cooking equipment) then the terms and conditions of the Manufacturer's Limited
Warranty will be rendered void and no warranty of any kind shall apply.
If the equipment has been changed, altered, modified or repaired by other than a qualified service technician during or after the 12-month limited warranty period, then the manufacturer shall not be liable for any incidental or consequential damages to any person or to any property which may result from the use of the equipment thereafter. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion thereto may not apply to you.
In the event you have any question concerning the installation, use, care. or service of the product, write Customer Service Department. Southbend Corporation. 1100 Old Honeycutt
Rd., Fuquay-Varina, North Carolina 27526.
INSTALLATION AND OPERATION
1100
Old Honeycutt Road
MANUAL
DIRECT STEAM POWER TILTING OR STATIONARY
20, 30, 40, 60 GALLON
southbend
A MIDDLEBY COMPANY
DMT
DMS
Fuquay-Varina, NC 27526 (919) 552-9161 FAX (919) 552-9798 (800) 348-2558
INSTALLATION AND OPERATION
It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This manual should be retained for future reference.
ADEQUATE CLEARANCES MUST BE MAINTAINED FOR SAFE AND PROPER OPERATION
I N D E X
DESCRIPTION INDEX
INSTALLATION AND SERVICE CONNECTIONS
INSTALLATION INSTRUCTIONS
INTRODUCTION
OPERATION PROCEDURES
OPERATION OF HYDRAULIC POWER UNIT
CLEANING INSTRUCTION TROUBLESHOOTING
PAGE
1
2
3
5
7
8
9
10
INSTALLATION & SERVICE CONNECTIONS
DIRECT CONNECTED
Steam supply - 3/4"(19mm) I.P.S. 5-35 PSI
S*
(.04-240 kg/cm2).
Cold Water - 3/8"(10mm) nominal tubing to
CW
kettle fill faucet. Drain - Pipe full 2" I.P.S. (50mm) to flush
D
drain. DO NOT MAKE SOLID CONNECTIONS TO DRAIN.
Condensate Return - 1/2" I.P.S. (13mm)
CR
connection for condensate return from kettle when specified.
EC 120V 60 Hz 1 PH. Tilt models only.
NOTES:
* Pressure reducing valve is required if incoming pressure exceeds 35
psi.
* Recess area for kettle draw off (dotted line) must be kept free of all
piping and connections.
* Tilting kettles shall be equipped with 6" (152mm) adjustable hold-down
feet in the rear.
As continued product improvement is a policy of Crown, specifications are subject to change without notice