Southbend SCX-10S-6-10 User Manual

Two ComparTmenT ConveCTion
S
Teamer wiTh 2 KeTTleS wiTh
S
Team Coil operaTion
Job Item#
SPECIFICATIONS:
steamer shall be constructed of satin nish stainless steel, type 304, with a cooking chamber of one-piece, all-welded, type 316 stainless
steel and shall be
SCX-2S, 14” W x 10.625” H x 21 D (355 mm x 270 mm x 533 mm).
SCX-10S, 14” W x 17” H x 21 D (355 mm x 432 mm x 533 mm).
The doors shall have a removable inner liner of stainless steel with full
steamer shall be provided with removable stainless steel pan supports and a stainless steel drip trough connected to drain in order to collect condensate when door is opened.
Each compartment’s control housing shall be constructed of stainless
steel with a fully removable side access panel. The controls shall include
an illuminated on/off power switch. The timing of each compartment
shall be independently controlled by a pilot ready light, a pilot cooking
light and a 60 minute electric timer which sounds an audible signal
reactivated when the door is closed. The cabinet base with steam coil boiler and controls shall be provided
with full perimeter painted angle frame, reinforced counter and boiler mountings, hinged door(s) with magnetic latch and 6” (152 mm) stainless steel legs with adjustable bullet feet on the front and adjustable anged feet on the rear for securing to the oor.
Boiler controls shall include automatic water level control, pressure gauge, water gauge glass, operating pressure control, safety high-limit pressure control and safety relief valve. Unit comes standard with a split water line, CSD-1 boiler code, “Y” - strainer, and automatic blowdown. The unit shall be ASME code stamped and National Board registere,
c-CSA-us and NSF certied.
Model description
SCX-2S-6-6
SCX-2S-6-10
SCX-10S-6-6
SCX-10S-6-10
OPERATION SHALL BE BY:
Steam coil heated steam boiler operating at 9-11 psi (62-76 kPa).
The boiler shall be equipped for operation on incoming steam
pressure of 25-45 psi (170-310 kPa) and a ow of 200 lbs. (90
kg) per hour. The controls shall be equipped for operation on:
115 VAC, 1 Phase, 60 Hz
OPTIONAL ITEMS AT EXTRA COST:
220 VAC, 1 Phase, 50 Hz
Secondary low water cut-off (California Code)
Solid state digital controls
Stainless steel back on cabinet
Stainless steel frame
Adjustable front anged feet
Load compensating timers
Correctional package
ACCESSORIES:
Ball oat trap (BFT)
Spray and rinse assembly
6 pan steamer with
(2) 6 gallon kettles
6 pan steamer with (1) 6 gallon and
(1) 10 gallon kettle
10 pan steamer with
(2) 6 gallon kettles
10 pan steamer with (1) 6 gallon and
(1) 10 gallon kettle
pan capacity per coMpartMent
pan depth
1” 2-1/2” 4” 6”
6 3 2 1
10 5 3 2
Form SCX2-6-6 Rev 0 (January/2014)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
SCX-2S-6-6 SCX-2S-6-10 SCX-10S-6-6 SCX-10S-6-10
Model a
SCX-2S-6-6 55.5 [1410] 930 lbs. [421] SCX-2S-6-10 55.5 [1410] 970 lbs. [439] SCX-10S-6-6 68.5 [1740] 1030 lbs. [467]
SCX-10S-6-10 68.5 [1740] 1070 lbs. [462]
shipping Weight
Min clearance
SIDES
BACK
0 0
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: 1/2” (13 mm) conduit connection to controls.
2 Amps per compartment or to be as specied on data plate.
– BOILER FEED WATER: 1/2” (13 mm) NPT at 25-50 PSI (170-345 kPa).
– CONDENSATE COLD WATER: 1/2” (13 mm) NPT at 25-50 PSI (170-345 kPa) (OPTIONAL)
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa).
– STEAM SUPPLY: 3/4” (19 mm) IPS for incoming steam at 40-50 PSI(276-345 kPa)*
– SINK DRAIN: 1-1/8” (29 mm) O.D. tubing.
s
* Pressure reducing valve is required if incoming pressure exceeds 50 PSI(345 kPa).
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 1.5 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY. CONTACT SOUTHBEND FOR WATER QUALITY SOLUTIONS.
WATER QUALITY STATEMENT
Form SCX2-6-6 Rev 0 (January/2014)
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
.